Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
XPSMCMEN0200SC – Speed monitoring 2 Sin/Cos encoder expansion module with screw term
XPSMCMEN0200SC
expansion module, Modicon MCM, speed monitoring, 2 SinCos encoder, screw

This Modicon MCM safe speed monitoring module has 2 Sin/Cos encoder inputs (with RJ45 connectors) and 2 proximity sensor inputs (connection via terminal) and is fitted with captive screw clamp terminals. It is designed to monitor zero speed control, max speed (limited speed), speed range and direction. It has a rated supply voltage of 24V DC. It offers up to four logically selectable limited speed thresholds (freely configurable via SoSafe Configurable software) for each logical intput (axis), and a maximum input frequency of 500kHz (for encoders) and 5kHz for proximity sensors. It completes your safety CPU with safe-speed monitoring function, ideal for cutting machines like band-saw, circular saw and grinding machines. This module figures LEDs on its front face, displaying the status (power supply, reset, internal or external errors, node address, encoder or proximity sensors connection status, speed monitoring status). The safe speed monitoring module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. This module can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PL = e conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL 3 conforming to IEC 62061. The modular safety controllers Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe speed monitoring module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Range Of Product Preventa Safety automation
Discrete Input Voltage 24 V DC
Product Or Component Type safe speed monitoring module
[Us] Rated Supply Voltage 24 V - 20...20 % DC
Electrical Connection screw terminal
Function Of Module speed monitoring
Device Short Name XPSMCM
Connections - Terminals
  • 2 captive screw clamp terminals, removable terminal block
  • 1 captive screw clamp terminals, removable terminal block
Number Of Terminal Blocks 4
Height 99 mm
Electrical Connection 1 connector RJ45 EIA/TIA-568-A
Integrated Connection Type backplane expansion bus
Cable Cross Section
  • 0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end
  • 0.2-2.5 mm² - AWG 24...AWG 14 solid without cable end
  • 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, with bezel
  • 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, without bezel
  • 0.2-1.5 mm² - AWG 24...AWG 16 flexible without cable end
  • 0.25-1 mm² - AWG 23...AWG 18 flexible with cable end, without bezel
  • 0.5-1.5 mm² - AWG 20...AWG 16 flexible with cable end, with double bezel
  • 0.2-1 mm² - AWG 24...AWG 18 solid without cable end
Power Consumption In W 3 W
Local Signalling
  • 1 LED green PWR power ON
  • 1 LED green RUN RUN (status)
  • 1 LED red E IN internal error
  • 1 LED red E EX external error
  • 2 LEDs orange ADDR node address
  • 2 LEDs yellow PROX proximity sensors connection status
  • 2 LEDs yellow SH speed monitoring status
  • 2 LEDs yellow ENC encoder connection status
Net Weight 0.3 kg
Maximum Input Frequency
  • 5 kHz sensor
  • 500 kHz encoder SinCos
Power Dissipation In W 3 W
Quality Labels CE
Mounting Support omega 35 mm DIN rail EN 50022
Sensor Type inductive proximity sensor
Width 114.5 mm
Depth 22.5 mm
Safety Level
  • can reach category 4 EN/ISO 13849-1
  • can reach PL = e EN/ISO 13849-1
  • type 4 EN/IEC 61496-1
  • SILCL 3 IEC 62061
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1409010EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1409010EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications
  • RCM
  • cULus
  • TÜV
Standards
  • EN/IEC 61508
  • EN/ISO 13849-1
  • EN/IEC 61496-1
  • EN/IEC 61800-5-1
  • IEC 62061
Pollution Degree 2
Ambient Air Temperature For Operation -10-55 °C
Electromagnetic Compatibility
  • electrostatic discharge immunity test 6 kV on contact) EN/IEC 61000-4-2
  • electrostatic discharge immunity test 20 kV on air) EN/IEC 61000-4-2
  • susceptibility to electromagnetic fields 10 V/m 80...1000 MHz) EN/IEC 61000-4-3
  • susceptibility to electromagnetic fields 30 V/m 1.4 GHz...2 GHz) EN/IEC 61000-4-3
Shock Resistance 10 gn 16 ms) 1000 shocks on each axis EN/IEC 61496-1
Vibration Resistance +/-0.35 mm 10-55 Hz)EN/IEC 61496-1
[Uimp] Rated Impulse Withstand Voltage 4 kV EN/IEC 61800-5
Ip Degree Of Protection IP20 enclosure)
Ambient Air Temperature For Storage -20-85 °C
Service Life 20 year(s)
Relative Humidity 10-95 %
Overvoltage Category II
Insulation 250 V AC between power supply and housing EN/IEC 61800-5-1
Documents
Royal Wholesale Electric

5.0

Powered by