Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
XALD222 – Control station, Harmony XALD, XALK, plastic, dark grey lid, 2 flush push buttons 22mm, marked UP ARROW DOWN ARROW, 2NO
XALD222
Control station, Harmony XALD, XALK, plastic, dark grey lid, 2 flush push buttons 22mm, marked UP ARROW DOWN ARROW, 2NO

This Harmony XALD dark grey control station is ideal to control simple hoists. This dark grey control station enables machine builders to easily add control and signalling functionality on their machines, with permanent modifications or damage to their machine body. It is designed for simple and mass production machines, textiles, packaging, handling small lifting systems, control of garage doors, rolling shutters, smoke extraction vents. It is compatible with Harmony XB5 range push buttons, switches and pilot lights. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments. It is also resistant to chemicals and offers double insulation.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Control Station Application two functions
Product Destination for XB5 Ø 22 mm control and signalling units
Range Of Product Harmony XALD
Colour Of Base Of Enclosure light grey RAL 7035)
Control Station Composition
  • 1 flush push-button, black 1 NO, white down arrow
  • 1 flush push-button, white 1 NO, black up arrow
Operators Description white ''up arrow'' 1 NO - black ''down arrow'' 1 NO
Product Or Component Type complete control station
Material polycarbonate
Marking Location marking on push-button
Operator Profile 2 flush push-buttons
Colour Of Cover dark grey RAL 7016)
Contact Operation slow-break
Device Short Name XALD
Warranty 18 months
Short-Circuit Protection 10 A cartridge fuse gG EN/IEC 60947-5-1
Operating Force 3.8 N NO changing electrical state
Operating Travel
  • 2.6 mm NO changing electrical state)
  • 4.3 mm total travel)
Contacts Material silver alloy (Ag/Ni)
Positive Opening without
[Ith] Conventional Free Air Thermal Current 10 A EN/IEC 60947-5-1
Cable Entry
  • 2 knock-outs for cable entry 14-14 mm
  • 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
Colour Of Marking
  • white marking when green, red or black caps
  • black marking when white caps
Net Weight 0.233 kg
[Uimp] Rated Impulse Withstand Voltage 6 kV EN/IEC 60947-1
Resistance To High Pressure Washer 7000000 Pa 55 °C 0.1 m
Electrical Durability
  • 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
  • 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
  • 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Connections - Terminals
  • screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1
  • screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1
[Ui] Rated Insulation Voltage 600 V 3)EN/IEC 60947-1
[Ie] Rated Operational Current
  • 6 A 120 V, AC-15, A600 EN/IEC 60947-5-1
  • 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1
  • 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
  • 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1
  • 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1
  • 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1
Mechanical Durability 10000000 cycles
Electrical Reliability
  • λ < 10exp(-6) 5 V 1 mA EN/IEC 60947-5-4
  • λ < 10exp(-8) 17 V 5 mA EN/IEC 60947-5-4
Tightening Torque 0.8-1.2 N.m EN/IEC 60947-1
Shape Of Screw Head
  • cross Philips no 1
  • cross pozidriv No 1
  • slotted flat Ø 4 mm
  • slotted flat Ø 5.5 mm
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1806010EN
Sustainable Offer Status Green Premium product
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1806010EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Ik Degree Of Protection IK03 EN 50102
Ambient Air Temperature For Operation -40-70 °C
Standards
  • JIS C8201-5-1
  • EN/IEC 60947-1
  • CSA C22.2 No 14
  • EN/IEC 60947-5-4
  • EN/IEC 60947-5-1
  • UL 508
  • EN/IEC 60947-5-5
  • JIS C8201-1
Shock Resistance
  • 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27
  • 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Vibration Resistance 5 gn 12-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
  • IP66 IEC 60529
  • IP67
  • IP69
  • IP69K
Ambient Air Temperature For Storage -40-70 °C
Nema Degree Of Protection
  • NEMA 13
  • NEMA 4X
Electrical Shock Protection Class class II IEC 60536
Protective Treatment TH
Documents