Thermal Losses |
90 W
|
Range Of Product |
Altivar
|
Product Or Component Type |
line/motor choke
|
Phase |
three phase
|
Value Of Inductance |
1 mH
|
Product Compatibility |
- variable speed drive ATV310 7.5 kW - motor choke - 1 per drive
- ATV31CD11N4 - line choke - 1 per drive
- variable speed drive ATV320 15 kW 525...600 V - three phase - motor choke - 1 per drive
- ATV312HU55M3 - line choke - 1 per drive
- LXM32.D30N4 - line choke - 1 per drive
- ATV71HD18Y - line choke - 1 per drive
- ATV312HD15S6 - motor choke - 1 per drive
- ATV312HD11S6 - motor choke - 1 per drive
- ATV312HD15N4 - line choke - 1 per drive
- ATV61WD11N4C - line choke - 1 per drive
- ATV61HD15N4 - line choke - 1 per drive
- ATV71WD15N4 - line choke - 1 per drive
- variable speed drive ATV340 7.5 kW 380...480 V - line choke - 1 per drive
- variable speed drive ATV930 18.5 kW 500...690 V - three phase - line choke - 1 per drive
- LXM32MC10N4 - line choke - 1 per drive
- ATV312HD11N4 - motor choke - 1 per drive
- variable speed drive ATV320 5.5 kW 200...240 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 7.5 kW 380...500 V - three phase - motor choke - 1 per drive
- variable speed drive ATV310 11 kW - line choke - 1 per drive
- ATV312HU40M3 - line choke - 1 per drive
- variable speed drive ATV320 5.5 kW 200...240 V - three phase - motor choke - 1 per drive
- ATV312HU40M3 - motor choke - 1 per drive
- ATV61HD22Y - line choke - 1 per drive
- variable speed drive ATV340 11 kW 380...480 V - line choke - 1 per drive
- ATV32HD11N4 - motor choke - 1 per drive
- variable speed drive ATV930 600 V - three phase - line choke - 25 hp - 1 per drive
- LXM32.D18N4 - line choke - 1 per drive
- variable speed drive ATV320 15 kW 380...500 V - three phase - line choke - 1 per drive
- ATV61HU55M3 - line choke - 1 per drive
- ATV32HD11N4 - line choke - 1 per drive
- ATV12PU40M3 - motor choke - 1 per drive
- variable speed drive ATV340 15 kW 380...480 V - line choke - 1 per drive
- LXM32.D72N4 - line choke - 1 per drive
- ATV312HU75N4 - motor choke - 1 per drive
- variable speed drive ATV320 11 kW 380...500 V - three phase - line choke - 1 per drive
- ATV61WD11N4 - line choke - 1 per drive
- ATV61HD11N4 - line choke - 1 per drive
- ATV71WD11N4 - line choke - 1 per drive
- ATV31CU75N4 - motor choke - 1 per drive
- variable speed drive ATV630 600 V - three phase - line choke - 30 hp - 1 per drive
- variable speed drive ATV320 4 kW 200...240 V - three phase - motor choke - 1 per drive
- ATV312HU75M3 - line choke - 1 per drive
- ATV61WD15N4 - line choke - 1 per drive
- variable speed drive ATV320 15 kW 525...600 V - three phase - line choke - 1 per drive
- variable speed drive ATV630 600 V - three phase - line choke - 25 hp - 1 per drive
- ATV31CD15N4 - line choke - 1 per drive
- ATV71PD11N4Z - line choke - 1 per drive
- ATV312HD11N4 - line choke - 1 per drive
- variable speed drive ATV320 11 kW 380...500 V - three phase - motor choke - 1 per drive
- ATV312HD15S6 - line choke - 1 per drive
- variable speed drive ATV320 7.5 kW 200...240 V - three phase - line choke - 1 per drive
- ATV61HD18Y - line choke - 1 per drive
- variable speed drive ATV630 18.5 kW 500...690 V - three phase - line choke - 1 per drive
- ATV32HD15N4 - line choke - 1 per drive
- ATV71HU40M3 - line choke - 1 per drive
- variable speed drive ATV310 7.5 kW - line choke - 1 per drive
- variable speed drive ATV930 600 V - three phase - line choke - 30 hp - 1 per drive
- variable speed drive ATV320 4 kW 200...240 V - three phase - line choke - 1 per drive
- ATV312HU55M3 - motor choke - 1 per drive
- variable speed drive ATV320 7.5 kW 200...240 V - three phase - motor choke - 1 per drive
- ATV312HU75M3 - motor choke - 1 per drive
- ATV61HU40M3 - line choke - 1 per drive
- variable speed drive ATV930 22 kW 500...690 V - three phase - line choke - 1 per drive
- ATV32HU75N4 - motor choke - 1 per drive
- variable speed drive ATV310 11 kW - motor choke - 1 per drive
- LXM32MD85N4 - line choke - 1 per drive
- ATV71HD11N4 - line choke - 1 per drive
- variable speed drive ATV320 11 kW 525...600 V - three phase - line choke - 1 per drive
- ATV71HD22Y - line choke - 1 per drive
- ATV31CD11N4 - motor choke - 1 per drive
- ATV71HD15N4 - line choke - 1 per drive
- variable speed drive ATV630 22 kW 500...690 V - three phase - line choke - 1 per drive
- ATV71HU55M3 - line choke - 1 per drive
- ATV12HU40M3 - motor choke - 1 per drive
- variable speed drive ATV320 11 kW 525...600 V - three phase - motor choke - 1 per drive
- ATV61WD15N4C - line choke - 1 per drive
|
Electrical Connection |
terminal 16 mm² / AWG 4, 1.2-1.4 N.m
|
Line Rated Current |
31 A
|
Range Compatibility |
- Lexium 32
- Altivar 312 Solar
- Easy Altivar 310
- Altivar 12
- Lexium 62
- Altivar 71
- Altivar Machine ATV340
- Altivar Machine ATV320
- Altivar Process ATV900
- Altivar 31C
- Altivar 61
- Lexium 52
- Altivar 32
- Altivar 312
- Altivar Process ATV600
- Easy Altivar 310L
|
Device Application |
- reduction of current harmonics
- reduction of overvoltages at motor terminals
|
Warranty |
18 months
|
Height |
170 mm
|
Net Weight |
6 kg
|
Leakage Distance |
11.5 mm IEC 60664
|
Electrical Insulation Class |
class F
|
Minimum Clearance Distance |
5.5 mm IEC 60664
|
Max Current |
1.65 x nominal current 60 s)
|
Width |
155 mm
|
Depth |
135 mm
|
Maximum Voltage Drop At Rated Load |
5 %
|
Supply Frequency |
50...60 Hz
|
Rohs Exemption Information |
Yes
|
Mercury Free |
Yes
|
Toxic Heavy Metal Free |
Yes
|
Reach Regulation |
Free of Substances of Very High Concern above the threshold
|
California Proposition 65 |
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Reach Free Of Svhc |
Yes
|
China Rohs Regulation |
X
|
Eu Rohs Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
|
Standards |
- EN 50178
- IEC 60076 (with HD398)
- VDE 0160 level 1
|
Ambient Air Temperature For Operation |
- 45-55 °C with current derating of 2 % per °C)
- 0-45 °C without current derating)
|
Shock Resistance |
15 gn 11 ms IEC 60068-2-27
|
Environmental Characteristic |
- 3B1 IEC 721-3-3
- 3C2 IEC 721-3-3
- 3S1 IEC 721-3-3
|
Vibration Resistance |
- 1 gn 13-200 Hz)IEC 60068-2-6
- 1.5 mm peak to peak 3-13 Hz)IEC 60068-2-6
|
Relative Humidity |
0-95 %
|
Pollution Degree |
2 EN 50178
|
Ambient Air Temperature For Storage |
-25-70 °C
|
Ip Degree Of Protection |
- choke IP00
- terminals IP10
|
Operating Altitude |
- <= 3280.84 ft (1000 m) without current derating
- 3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
|