Thermal Losses |
75 W
|
Range Of Product |
Altivar
|
Product Or Component Type |
line/motor choke
|
Phase |
three phase
|
Value Of Inductance |
2 mH
|
Product Compatibility |
- variable speed drive ATV340 4 kW 380...480 V - line choke - 1 per drive
- ATV31CU22M2 - motor choke - 1 per drive
- ATV31CU55N4 - line choke - 1 per drive
- ATV31CU55N4 - motor choke - 1 per drive
- ATV31CU75N4 - line choke - 1 per drive
- ATV61HD11Y - line choke - 1 per drive
- ATV61HD15Y - line choke - 1 per drive
- ATV61HU30M3 - line choke - 1 per drive
- ATV61HU55N4 - line choke - 1 per drive
- ATV61HU75N4 - line choke - 1 per drive
- ATV61WU55N4 - line choke - 1 per drive
- ATV61WU55N4C - line choke - 1 per drive
- ATV61WU75N4 - line choke - 1 per drive
- ATV61WU75N4C - line choke - 1 per drive
- ATV71HD11Y - line choke - 1 per drive
- ATV71HD15Y - line choke - 1 per drive
- ATV71HU30M3 - line choke - 1 per drive
- ATV71HU55N4 - line choke - 1 per drive
- ATV71HU75N4 - line choke - 1 per drive
- ATV71PU55N4Z - line choke - 1 per drive
- ATV71PU75N4Z - line choke - 1 per drive
- ATV71WU55N4 - line choke - 1 per drive
- ATV71WU75N4 - line choke - 1 per drive
- LXM05D42M3X - line choke - 1 per drive
- ATV12HU22M2 - motor choke - 1 per drive
- ATV12HU22M3 - motor choke - 1 per drive
- ATV312HD11S6 - line choke - 1 per drive
- ATV312HU22M3 - line choke - 1 per drive
- ATV312HU30M3 - line choke - 1 per drive
- ATV312HU55N4 - line choke - 1 per drive
- ATV312HU75N4 - line choke - 1 per drive
- ATV312HU75S6 - line choke - 1 per drive
- ATV71HU75S6X - line choke - 1 per drive
- ATV312HU22M3 - motor choke - 1 per drive
- ATV312HU30M3 - motor choke - 1 per drive
- ATV312HU55N4 - motor choke - 1 per drive
- ATV312HU75S6 - motor choke - 1 per drive
- ATV312HU22M2 - motor choke - 1 per drive
- ATV12HU30M3 - motor choke - 1 per drive
- ATV12PU22M3 - motor choke - 1 per drive
- ATV12PU30M3 - motor choke - 1 per drive
- ATV61HU75S6X - line choke - 1 per drive
- ATV32HU55N4 - line choke - 1 per drive
- ATV32HU75N4 - line choke - 1 per drive
- ATV32HU22M2 - motor choke - 1 per drive
- ATV32HU55N4 - motor choke - 1 per drive
- LXM32.D12N4 - line choke - 1 per drive
- LXM32.U60N4 - line choke - 1 per drive
- variable speed drive ATV310 4 kW - line choke - 1 per drive
- variable speed drive ATV310 5.5 kW - line choke - 1 per drive
- variable speed drive ATV310 5.5 kW - motor choke - 1 per drive
- variable speed drive ATV340 5.5 kW 380...480 V - line choke - 1 per drive
- variable speed drive ATV340 7.5 kW 380...480 V - line choke - 1 per drive
- variable speed drive ATV320 5.5 kW 380...500 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 7.5 kW 380...500 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 2.2 kW 200...240 V - single phase - motor choke - 1 per drive
- variable speed drive ATV320 5.5 kW 380...500 V - three phase - motor choke - 1 per drive
- variable speed drive ATV320 2.2 kW 200...240 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 3 kW 200...240 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 2.2 kW 200...240 V - three phase - motor choke - 1 per drive
- variable speed drive ATV320 3 kW 200...240 V - three phase - motor choke - 1 per drive
- variable speed drive ATV320 5.5 kW 525...600 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 7.5 kW 525...600 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 7.5 kW 525...600 V - three phase - motor choke - 1 per drive
- variable speed drive ATV630 11 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV630 15 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV930 11 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV930 15 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV630 600 V - three phase - line choke - 10 hp - 1 per drive
- variable speed drive ATV630 600 V - three phase - line choke - 15 hp - 1 per drive
- variable speed drive ATV930 600 V - three phase - line choke - 10 hp - 1 per drive
- variable speed drive ATV930 600 V - three phase - line choke - 15 hp - 1 per drive
- variable speed drive ATV310L 0.75 kW
- variable speed drive ATV310L 1.5 kW
- variable speed drive ATV310L 2.2 kW
- variable speed drive ATV310L 3.0 kW
- variable speed drive ATV310L 4.0 kW
- variable speed drive ATV310L 5.5 kW
|
Electrical Connection |
terminal 6 mm² / AWG 8, 0.8-1 N.m
|
Line Rated Current |
17 A
|
Range Compatibility |
- Altivar 61
- Altivar Process ATV900
- Lexium 05
- Altivar 312 Solar
- Altivar Process ATV600
- Altivar 32
- Altivar 71
- Lexium 62
- Easy Altivar 310
- Altivar 12
- Altivar 31C
- Lexium 52
- Altivar 312
- Lexium 32
- Altivar Machine ATV320
- Altivar Machine ATV340
- Easy Altivar 310L
|
Device Application |
- reduction of current harmonics
- reduction of overvoltages at motor terminals
|
Warranty |
18 months
|
Height |
155 mm
|
Net Weight |
3.5 kg
|
Leakage Distance |
11.5 mm IEC 60664
|
Electrical Insulation Class |
class F
|
Minimum Clearance Distance |
5.5 mm IEC 60664
|
Max Current |
1.65 x nominal current 60 s)
|
Width |
130 mm
|
Depth |
90 mm
|
Maximum Voltage Drop At Rated Load |
5 %
|
Supply Frequency |
50...60 Hz
|
Rohs Exemption Information |
Yes
|
Mercury Free |
Yes
|
Toxic Heavy Metal Free |
Yes
|
Reach Regulation |
Free of Substances of Very High Concern above the threshold
|
California Proposition 65 |
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Reach Free Of Svhc |
Yes
|
China Rohs Regulation |
X
|
Eu Rohs Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
|
Standards |
- VDE 0160 level 1
- EN 50178
- IEC 60076 (with HD398)
|
Ambient Air Temperature For Operation |
- 45-55 °C with current derating of 2 % per °C)
- 0-45 °C without current derating)
|
Shock Resistance |
15 gn 11 ms IEC 60068-2-27
|
Environmental Characteristic |
- 3B1 IEC 721-3-3
- 3C2 IEC 721-3-3
- 3S1 IEC 721-3-3
|
Vibration Resistance |
- 1 gn 13-200 Hz)IEC 60068-2-6
- 1.5 mm peak to peak 3-13 Hz)IEC 60068-2-6
|
Relative Humidity |
0-95 %
|
Pollution Degree |
2 EN 50178
|
Ambient Air Temperature For Storage |
-25-70 °C
|
Ip Degree Of Protection |
- choke IP00
- terminals IP20
|
Operating Altitude |
- <= 3280.84 ft (1000 m) without current derating
- 3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
|