Thermal Losses |
45 W
|
Range Of Product |
Altivar
|
Product Or Component Type |
line/motor choke
|
Phase |
three phase
|
Value Of Inductance |
10 mH
|
Product Compatibility |
- ATV12H018F1 - motor choke - 1 per drive
- ATV12H018M2 - motor choke - 1 per drive
- ATV12H018M3 - motor choke - 1 per drive
- ATV12H037F1 - motor choke - 1 per drive
- ATV12H037M2 - motor choke - 1 per drive
- ATV12H037M3 - motor choke - 1 per drive
- ATV12H055M2 - motor choke - 1 per drive
- ATV12P037F1 - motor choke - 1 per drive
- ATV12P037M2 - motor choke - 1 per drive
- ATV12P037M3 - motor choke - 1 per drive
- ATV12P055M2 - motor choke - 1 per drive
- ATV312H018M3 - line choke - 1 per drive
- ATV312H037M3 - line choke - 1 per drive
- ATV312H037N4 - line choke - 1 per drive
- ATV312H055M3 - line choke - 1 per drive
- ATV312H055N4 - line choke - 1 per drive
- ATV312H075M3 - line choke - 1 per drive
- ATV312H075N4 - line choke - 1 per drive
- ATV312H075S6 - line choke - 1 per drive
- ATV312HU11N4 - line choke - 1 per drive
- ATV312HU15N4 - line choke - 1 per drive
- ATV312HU15S6 - line choke - 1 per drive
- ATV32H037N4 - line choke - 1 per drive
- ATV32H055N4 - line choke - 1 per drive
- ATV32H075N4 - line choke - 1 per drive
- ATV32HU11N4 - line choke - 1 per drive
- ATV32HU15N4 - line choke - 1 per drive
- ATV61H075M3 - line choke - 1 per drive
- ATV61H075N4 - line choke - 1 per drive
- ATV61HU15N4 - line choke - 1 per drive
- ATV61HU30Y - line choke - 1 per drive
- ATV61W075N4 - line choke - 1 per drive
- ATV61W075N4C - line choke - 1 per drive
- ATV61WU15N4 - line choke - 1 per drive
- ATV61WU15N4C - line choke - 1 per drive
- ATV71H037M3 - line choke - 1 per drive
- ATV71H075M3 - line choke - 1 per drive
- ATV71H075N4 - line choke - 1 per drive
- ATV71HU15N4 - line choke - 1 per drive
- ATV71HU22Y - line choke - 1 per drive
- ATV71HU30Y - line choke - 1 per drive
- ATV71P075N4Z - line choke - 1 per drive
- ATV71PU15N4Z - line choke - 1 per drive
- ATV71W075N4 - line choke - 1 per drive
- ATV71WU15N4 - line choke - 1 per drive
- ATV61HU22S6X - line choke - 1 per drive
- ATV71HU15S6X - line choke - 1 per drive
- ATV71HU22S6X - line choke - 1 per drive
- ATV31C037N4 - line choke - 1 per drive
- ATV31C055N4 - line choke - 1 per drive
- ATV31C075N4 - line choke - 1 per drive
- ATV31CU11N4 - line choke - 1 per drive
- ATV31CU15N4 - line choke - 1 per drive
- variable speed drive ATV310 0.37 kW - line choke - 1 per drive
- variable speed drive ATV310 0.75 kW - line choke - 1 per drive
- variable speed drive ATV340 0.75 kW 380...480 V - line choke - 1 per drive
- variable speed drive ATV340 1.5 kW 380...480 V - line choke - 1 per drive
- variable speed drive ATV320 0.37 kW 380...500 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 0.55 kW 380...500 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 0.75 kW 380...500 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 1.1 kW 380...500 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 1.5 kW 380...500 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 0.18 kW 200...240 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 0.37 kW 200...240 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 0.55 kW 200...240 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 0.75 kW 200...240 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 0.75 kW 525...600 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 1.5 kW 525...600 V - three phase - line choke - 1 per drive
- variable speed drive ATV320 2.2 kW 525...600 V - three phase - line choke - 1 per drive
- variable speed drive ATV630 2.2 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV630 3 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV630 4 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV930 2.2 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV930 3 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV930 4 kW 500...690 V - three phase - line choke - 1 per drive
- variable speed drive ATV630 600 V - three phase - line choke - 3 hp - 1 per drive
- variable speed drive ATV930 600 V - three phase - line choke - 3 hp - 1 per drive
- variable speed drive ATV310L 0.75 kW
- variable speed drive ATV310L 1.5 kW
- variable speed drive ATV310L 2.2 kW
- variable speed drive ATV310L 3.0 kW
- variable speed drive ATV310L 4.0 kW
- variable speed drive ATV310L 5.5 kW
|
Electrical Connection |
terminal 2.5 mm² / AWG 12, 0.4-0.6 N.m
|
Line Rated Current |
4 A
|
Range Compatibility |
- Altivar 61
- Altivar 312
- Altivar Process ATV900
- Altivar 32
- Altivar 312 Solar
- Altivar Process ATV600
- Altivar 31C
- Lexium 62
- Easy Altivar 310
- Altivar Machine ATV340
- Altivar Machine ATV320
- Altivar 71
- Altivar 12
- Easy Altivar 310L
|
Device Application |
reduction of current harmonics
|
Warranty |
18 months
|
Height |
135 mm
|
Net Weight |
1.5 kg
|
Leakage Distance |
11.5 mm IEC 60664
|
Electrical Insulation Class |
class F
|
Minimum Clearance Distance |
5.5 mm IEC 60664
|
Max Current |
1.65 x nominal current 60 s)
|
Width |
100 mm
|
Depth |
60 mm
|
Maximum Voltage Drop At Rated Load |
5 %
|
Supply Frequency |
50...60 Hz
|
Rohs Exemption Information |
Yes
|
Mercury Free |
Yes
|
Toxic Heavy Metal Free |
Yes
|
Reach Regulation |
Free of Substances of Very High Concern above the threshold
|
California Proposition 65 |
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Reach Free Of Svhc |
Yes
|
China Rohs Regulation |
X
|
Eu Rohs Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
|
Standards |
- VDE 0160 level 1
- IEC 60076 (with HD398)
- EN 50178
|
Ambient Air Temperature For Operation |
- 45-55 °C with current derating of 2 % per °C)
- 0-45 °C without current derating)
|
Shock Resistance |
15 gn 11 ms IEC 60068-2-27
|
Environmental Characteristic |
- 3B1 IEC 721-3-3
- 3C2 IEC 721-3-3
- 3S1 IEC 721-3-3
|
Vibration Resistance |
- 1 gn 13-200 Hz)IEC 60068-2-6
- 1.5 mm peak to peak 3-13 Hz)IEC 60068-2-6
|
Relative Humidity |
0-95 %
|
Pollution Degree |
2 EN 50178
|
Ambient Air Temperature For Storage |
-25-70 °C
|
Ip Degree Of Protection |
- choke IP00
- terminals IP20
|
Operating Altitude |
- <= 3280.84 ft (1000 m) without current derating
- 3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
|