Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
SR3B101BD – Modular smart relay, Zelio Logic, 10 I/O, 24 V DC, clock, display
SR3B101BD
modular smart relay, Zelio Logic SR2 SR3, 10 IO, 24V DC, clock, display, 4 relay outputs

This Schneider Electric Zelio Logic SR3 compact smart relay / programmable controller uses a supply voltage of 24 volts direct current, has 10 inputs / outputs with screw-clamp terminals. It has an integrated clock and LCD display. This compact smart relays / programmable controller is ideal for management, remote control or monitoring of simple automation systems. It is suitable for both industrial and commercial applications. It has compact form-factor, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Simple ladder programming, adapted for non-specialists. Discovery package, coming with Zelio Soft programming software, the simplest way to learn and use this relay. Built-in EEPROM flash memory for data backup up to 10 years, easy-to-recover after a power shortage or incident. More I/O than SR2 model, for larger applications. Simple to select, install and program, Zelio Logic is suitable for all your applications. Flexible, it offers you the choice of 2 ranges, compact or modular, extendable and 2 programming languages (FBD or LADDER). Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Range Of Product Zelio Logic
Product Or Component Type modular smart relay
Warranty 18 months
Contacts Type And Composition NO relay output
Input Impedance
  • 12 kOhm IB...IG used as analogue input circuit
  • 12 kOhm IB...IG used as discrete input circuit
  • 7.4 kOhm I1...IA and IH...IR discrete input circuit
Discrete Input Type resistive
Number Of Outputs 4 relay
Analogue Input Range
  • 0...10 V
  • 0...24 V
Conversion Error
  • +/- 5 % 25 °C analogue input circuit
  • +/- 6.2 % 55 °C analogue input circuit
Output Thermal Current 8 A for all 4 outputs relay output
Discrete Input Voltage 24 V DC
Number Or Control Scheme Lines
  • 0-500 FBD
  • 0-240 ladder
Lsb Value 39 mV analogue input circuit
Backup Time 10 years 25 °C
Clock Drift
  • 12 min/year 0-55 °C
  • 6 s/month 25-25 °C
Analogue Input Type common mode
Discrete Input Current 4 mA
Current State 1 Guaranteed
  • >= 1.2 mA IB...IG used as discrete input circuit)
  • >= 2.2 mA I1...IA and IH...IR discrete input circuit)
Response Time
  • 10 ms from state 0 to state 1)relay output
  • 5 ms from state 1 to state 0)relay output
Clock with
Power Dissipation In W
  • 3 W without extension
  • 8 W with extensions
Local Display with
Net Weight 0.25 kg
[Uimp] Rated Impulse Withstand Voltage 4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Voltage State 0 Guaranteed
  • <= 5 V I1...IA and IH...IR discrete input circuit
  • <= 5 V IB...IG used as discrete input circuit
  • <= 5 V
Output Voltage Limits
  • 24...250 V AC relay output)
  • 5...30 V DC relay output)
Conversion Time smart relay cycle time analogue input circuit
Electrical Durability
  • AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1
  • AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1
  • DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1
  • DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1
Connections - Terminals
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid
  • screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid
  • screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end
Analogue Input Number 4
Voltage State 1 Guaranteed
  • >= 15 V I1...IA and IH...IR discrete input circuit
  • >= 15 V IB...IG used as discrete input circuit
Input Compatibility 3-wire proximity sensors PNP discrete input
Current State 0 Guaranteed
  • <= 0.5 mA IB...IG used as discrete input circuit)
  • <= 0.75 mA I1...IA and IH...IR discrete input circuit)
Supply Voltage Limits 19.2-30 V
Operating Distance 10 m between stations, with screened cable (sensor not isolated) analogue input circuit
Overvoltage Category III EN/IEC 60664-1
Mechanical Durability 10000000 cycles relay output
Maximum Supply Current
  • 100 mA with extensions)
  • 100 mA without extension)
Tightening Torque 0.5 N.m
Temperature Probe Type
  • NTC 10k 25 °C
  • NTC 1000k 25 °C
  • KTY81 210/220/221/222/250
  • Pt 500
Switching Capacity In Ma >= 10 mA 12 V relay output)
Analogue Input Resolution 8 bits
Operating Rate In Hz
  • 0.1 Hz at Ie)relay output
  • 10 Hz no load)relay output
Counting Frequency 1 kHz discrete input
Discrete Input Number 6 EN/IEC 61131-2 type 1
Cycle Time 6-90 ms
Reverse Polarity Protection with
Maximum Permissible Voltage 30 V analogue input circuit
Repeat Accuracy +/- 2 % 55 °C analogue input circuit
[Us] Rated Supply Voltage 24 V
Checks program memory on each power up
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP060406EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI0604006EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications
  • GOST
  • UL
  • C-tick
  • CSA
  • GL
Standards
  • EN/IEC 60068-2-6 Fc
  • EN/IEC 61000-4-11
  • EN/IEC 60068-2-27 Ea
  • EN/IEC 61000-4-4 level 3
  • EN/IEC 61000-4-3
  • EN/IEC 61000-4-6 level 3
  • EN/IEC 61000-4-2 level 3
  • EN/IEC 61000-4-5
  • EN/IEC 61000-4-12
Disturbance Radiated/Conducted class B EN 55022-11 group 1
Ambient Air Temperature For Operation
  • -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2
  • -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
Immunity To Microbreaks 1 ms
Environmental Characteristic
  • EMC directive EN/IEC 61000-6-2
  • EMC directive EN/IEC 61000-6-3
  • EMC directive EN/IEC 61000-6-4
  • EMC directive EN/IEC 61131-2 zone B
  • low voltage directive EN/IEC 61131-2
Ip Degree Of Protection
  • IP20 IEC 60529 terminal block)
  • IP40 IEC 60529 front panel)
Pollution Degree 2 EN/IEC 61131-2
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 95-95 % without condensation or dripping water
Maximum Altitude Transport 3048 m
Operating Altitude 6561.68 ft (2000 m)
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews