Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
RM35HZ21FM – Modular frequency control relay, Harmony, 5A, 1CO 1CO, 120…277V AC
RM35HZ21FM
Modular frequency control relay, Harmony, 5A, 1CO+1CO, 120…277V AC

This Harmony RM35-HZ control relay allows monitoring of frequency control. This modular control relay is ideal for monitoring of frequency variations in electrical power sources such as wind turbine and micro-power stations. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides an automatic detection of abnormal electrical values before they incur serious damage to machinery thus reducing your maintenance and downtime costs. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Minimum Switching Current 10 mA 5 V DC
Range Of Product Harmony Control Relays
Measurement Range 40...70 Hz frequency
Switching Capacity In Va 1250 VA
Product Or Component Type frequency control relay
Utilisation Category
  • AC-12 IEC 60947-5-1
  • AC-13 IEC 60947-5-1
  • AC-14 IEC 60947-5-1
  • AC-15 IEC 60947-5-1
  • DC-12 IEC 60947-5-1
  • DC-13 IEC 60947-5-1
  • DC-14 IEC 60947-5-1
Relay Name RM35HZ21FM
Relay Type frequency control relays
Time Delay Type adjustable 0.1...10 s, +/- 10 % on crossing the threshold
Relay Monitored Parameters overfrequency and underfrequency 50 or 60 Hz
Maximum Power Consumption In Va 6 VA AC
Warranty 18 months
Maximum Measuring Cycle 200 ms measurement cycle as true rms value
Hysteresis 0.3-0.3 % fixed
Insulation Resistance
  • > 500 MOhm 500 V DC between supply and relay output IEC 60255-5
  • > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1
  • > 1 MOhm 500 V DC between supply and measurement IEC 60255-5
  • > 500 MOhm 500 V DC between supply and relay output IEC 60664-1
  • > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5
  • > 1 MOhm 500 V DC between supply and measurement IEC 60664-1
Measurement Error
  • +/- 0.05 %/°C with temperature variation
  • < +/- 1 % over the whole range with voltage variation
[Us] Rated Supply Voltage 120...277 V AC
Operating Rate <= 360 operations/hour full load
Status Led
  • 1 LED Green power ON
  • 1 LED Yellow correct frequency (high R1)
  • 1 LED Yellow correct frequency (low R2)
Output Contacts 1 C/O + 1 C/O
Contacts Material cadmium free
Marking
  • CE : 73/23/EEC
  • CE : EMC 89/336/EEC
Operating Position any position without derating
Maximum Switching Voltage 250 V AC/DC
Threshold Setting
  • -2...10 Hz
  • -10...2 Hz
Reset Time 2000 ms time delay
Connections - Terminals
  • screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Ui] Rated Insulation Voltage 400 V IEC 60664-1
Overvoltage Category III IEC 60664-1
Insulation no galvanic insulation between supply and measurement
Supply Voltage Limits 102-308 V AC
Mounting Support 35 mm symmetrical DIN rail conforming to EN/IEC 60715
Nominal Output Current 5 A
Mechanical Durability 30000000 cycles
Input Frequency 70 Hz
Housing Material self-extinguishing plastic
Control Circuit Voltage Limits 15 % + 10 % Un
Control Circuit Frequency 40...70 Hz
Measurement Accuracy
  • +/- 10 % of the full scale value in input
  • +/- 10 % of the full scale value in time delay
Width 35 mm
Tightening Torque 0.6-1 N.m IEC 60947-1
Electrical Durability 100000 cycles
Run-Up Delay At Power-Up 0.5 s
Repeat Accuracy
  • +/- 0.5 % input and measurement circuit
  • +/- 0.5 % time delay
Supply Frequency 50/60 Hz +/- 10 %
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1504008EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation X
Circularity Profile ENVEOLI1504008EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications
  • GL
  • UL
  • CSA
  • C-tick
  • GOST
Ambient Air Temperature For Operation -20-50 °C
Standards
  • IEC 60255-6
  • NF EN 60255-6
Immunity To Microbreaks 10 ms
Dielectric Test Voltage 2 kV AC 50 Hz
Electromagnetic Compatibility
  • emission standard for industrial environments EN/IEC 61000-6-4
  • emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3
  • immunity for industrial environments NF EN/IEC 61000-6-2
Shock Resistance 15 gn 11 ms IEC 60255-21-1
Vibration Resistance
  • 0.35 mm 5-57.6 Hz)IEC 60068-2-6/IEC 60255-21-1
  • 1 gn 57.6-150 Hz)IEC 60068-2-6/IEC 60255-21-1
Ip Degree Of Protection
  • IP20 IEC 60529 terminals)
  • IP30 IEC 60529 casing)
Pollution Degree 3 IEC 60664-1
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 95-95 % 55-55 °C IEC 60068-2-30
Non-Dissipating Shock Wave 4 kV
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews