This Harmony RM35AT control relay allows monitoring of temperature control." "This modular control relay is ideal for monitoring of electrical values and temperature variation in industrial and building control panels." "It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water." "It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device." "It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers." "It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting." "Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC." 0 0 0 0 0 0 0 0 0
Brand: Schneider Electric
Add to Quote CatalogueMinimum Switching Current | 10 mA 5 V DC |
---|---|
Range Of Product | Harmony Control Relays |
Switching Capacity In Va | 1250 VA |
Product Or Component Type | temperature control relay |
Utilisation Category |
|
Relay Name | RM35AT |
Time Delay Range | 0.1...10 s adjustable 0...10 % of the full scale value) |
Relay Type | temperature control relays |
Product Specific Application | for elevator machine rooms and 3-phase supplies |
Relay Monitored Parameters |
|
Maximum Power Consumption In Va | 3.5 VA AC |
Warranty | 18 months |
Temperature Probe Type | Pt 100 - 3-wire |
Insulation Resistance |
|
[Us] Rated Supply Voltage | 24...240 V AC/DC |
Operating Rate | <= 360 operations/hour full load |
Status Led |
|
Output Contacts | 1 C/O |
Contacts Material | cadmium free |
Installed Device | Pt 100 probe cable length <= 10 m |
Reset Time | 8 s |
Marking |
|
Response Time |
|
Operating Position | any position without derating |
Maximum Switching Voltage | 250 V AC/DC |
Connections - Terminals |
|
[Ui] Rated Insulation Voltage | 250 V IEC 60664-1 |
Overvoltage Category | III IEC 60664-1 |
Insulation | galvanic insulation between supply and measurement |
Supply Voltage Limits |
|
Mounting Support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
Nominal Output Current | 5 A |
Mechanical Durability | 30000000 cycles |
Housing Material | self-extinguishing plastic |
Resistance Across Terminals | 1.33 kOhm temperature |
Control Circuit Voltage Limits |
|
Measurement Accuracy | +/- 2 °C |
Width | 35 mm |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Maximum Power Consumption In W | 0.6 W DC |
Electrical Durability | 100000 cycles |
Run-Up Delay At Power-Up | 0.2 s |
Supply Frequency | 50/60 Hz +/- 10 % |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1504008EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI1504008EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Product Certifications |
|
Ambient Air Temperature For Operation | -20-50 °C |
Standards |
|
Immunity To Microbreaks | 10 ms |
Dielectric Test Voltage | 2 kV AC 50 Hz, 1 min |
Electromagnetic Compatibility |
|
Shock Resistance | 15 gn 11 ms IEC 60255-21-1 |
Vibration Resistance |
|
Ip Degree Of Protection |
|
Pollution Degree | 3 IEC 60664-1 |
Ambient Air Temperature For Storage | -40-70 °C |
Non-Dissipating Shock Wave | 4 kV |