This Harmony RM22-LA relay allows monitoring of liquid level control in 3-phase networks. This modular multi function 3-phase liquid level control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Minimum Switching Current 10 mA 5 V DC
Maximum Switching Current 8 A AC
Range Of Product Harmony Control Relays
Switching Capacity In Va 2000 VA
Product Or Component Type level control relay
Utilisation Category
  • AC-15 IEC 60947-5-1
  • DC-13 IEC 60947-5-1
  • AC-1 IEC 60947-4-1
  • DC-1 IEC 60947-4-1
Relay Name RM22L
Contacts Type And Composition 2 C/O
Relay Type level control relay
Time Delay Type adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
Relay Monitored Parameters detection by resistive probes
[Us] Rated Supply Voltage 24...240 V AC/DC 50/60 Hz
Safety Reliability Data
  • MTTFd = 182.6 years
  • B10d = 170000
Maximum Electrode Voltage 12 V AC
Cable Capacitance
  • 1 nF HS (High Sensitivity) probe cable
  • 2.2 nF St (Standard Sensitivity) probe cable
  • 4.7 nF LS (Low Sensitivity) probe cable
Measurement Error
  • < 1 % over the whole range with voltage variation
  • 0.05 %/°C with temperature variation
Maximum Cable Distance Between Devices 1000 m probe and delay
Output Contacts 2 C/O
Contacts Material cadmium free
Sensitivity Scale
  • 0.25...5 kOhm LS (Low Sensitivity)
  • 5...100 kOhm St (Standard Sensitivity)
  • 50...1000 kOhm HS (High Sensitivity)
Net Weight 0.11 kg
Maximum Switching Voltage 250 V AC
Maximum Electrode Current 1 mA
Connections - Terminals
  • screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
  • screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Overvoltage Category III IEC 60664-1
Insulation between supply and measurement
Supply Voltage Limits 20.4-264 V AC/DC
Mounting Support 35 mm DIN rail conforming to EN/IEC 60715
Nominal Output Current 8 A
Mechanical Durability 10000000 cycles
Maximum Supply Current For Sensors 1 mA
Housing Material self-extinguishing plastic
Mounting Position any position
Width 22.5 mm
Tightening Torque 0.6-1 N.m IEC 60947-1
Maximum Power Consumption In W 1.5 W DC
Sensitivity Adjustment 5-100 %
Electrical Durability 100000 cycles
Run-Up Delay At Power-Up
  • 2.5 s
  • 0.6 s
Repeat Accuracy +/- 2 % time delay
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1504008EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation X
Circularity Profile ENVEOLI1504008EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications
  • UL
  • RCM
  • CSA
  • GL
  • CCC
  • CE
  • EAC
Standards EN/IEC 60255-1
Dielectric Test Voltage 2.5 kV AC 50 Hz, 1 min IEC 60255-27
Electromagnetic Compatibility
  • immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1
  • immunity for industrial environments EN/IEC 61000-6-2
  • emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3
  • emission standard for industrial environments EN/IEC 61000-6-4
  • electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2
  • electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2
  • radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3
  • electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4
  • electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4
  • surge immunity test 4 kV common mode)level 4 IEC 61000-4-5
  • surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5
  • conducted and radiated emissionsclass B group 1 CISPR 11
  • conducted and radiated emissionsclass B CISPR 22
Immunity To Microbreaks
  • 100 ms DC
  • 90 ms AC
Shock Resistance
  • 15 gn 11 ms) not in operation IEC 60068-2-27
  • 5 gn 11 ms) in operation IEC 60068-2-27
Vibration Resistance
  • 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6
  • 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6
  • 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6
  • 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
Ip Degree Of Protection
  • IP20 IEC 60529 terminals)
  • IP40 IEC 60529 housing)
  • IP50 IEC 60529 front panel)
Pollution Degree 3 IEC 60664-1
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 93-97 % 25-55 °C IEC 60068-2-30