RM17UAS14 – Modular 1 phaseVoltage control relay, Harmony, 5A, 1CO, 9…15V DC
RM17UAS14
Modular 1 phaseVoltage control relay, Harmony, 5A, 1CO, 9…15V DC

This Harmony RM17-U control relay allows monitoring of voltage control." "This modular control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels." "It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water." "It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device." "It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers." "It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting." "Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC." 0 0 0 0 0 0 0 0 0

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Minimum Switching Current 10 mA 5 V DC
Maximum Switching Current 5 A AC/DC
Range Of Product Harmony Control Relays
Measurement Range 9...15 V voltage DC
Switching Capacity In Va 1250 VA
Product Or Component Type voltage control relay
Utilisation Category
  • AC-12 IEC 60947-5-1
  • AC-13 IEC 60947-5-1
  • AC-14 IEC 60947-5-1
  • AC-15 IEC 60947-5-1
  • DC-12 IEC 60947-5-1
  • DC-13 IEC 60947-5-1
  • DC-14 IEC 60947-5-1
Relay Name RM17UAS
Contacts Type And Composition 1 C/O
Relay Type voltage control relay
Product Specific Application for single-phase and DC supply
Time Delay Type adjustable 0.1...10 s, 0 + 10 % on crossing the threshold
Relay Monitored Parameters
  • overvoltage or undervoltage detection
  • self-powered
Warranty 18 months
[Us] Rated Supply Voltage 12 V DC +/- 10 %
Hysteresis 5-20 % threshold setting
Insulation Resistance
  • > 500 MOhm 500 V DC IEC 60255-5
  • > 500 MOhm 500 V DC IEC 60664-1
Measurement Error
  • < 1 % over the whole range with voltage variation
  • 0.2 %/°C with temperature variation
Operating Rate <= 360 operations/hour full load
Output Contacts 1 C/O
Immunity To Microbreaks 20 ms 12 V
Polarity non reversible polarity on DC supply
Operating Position any position without derating
Net Weight 0.08 kg
Maximum Switching Voltage 250 V AC/DC
Reset Time 1500 ms time delay
Run-Up Delay At Power-Up 1000 ms DC
Connections - Terminals
  • screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
  • screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Ui] Rated Insulation Voltage
  • 250 V IEC 60664-1
  • 400 V IEC 60664-1
Overvoltage Category III IEC 60664-1
Quality Labels CE
Supply Voltage Limits 7-20 V DC
Mounting Support 35 mm symmetrical DIN rail conforming to EN/IEC 60715
Nominal Output Current 5 A
Local Signalling
  • for power ON LED (green)
  • for relay ON LED (yellow)
Mechanical Durability 30000000 cycles
Compatibility Code RM17
Housing Material self-extinguishing plastic
Measurement Accuracy +/- 10 % of the full scale value
Width 17.5 mm
Tightening Torque 0.6-1 N.m IEC 60947-1
Maximum Power Consumption In W 1 W DC
Electrical Durability 100000 cycles
Repeat Accuracy
  • +/- 0.5 % input and measurement circuit
  • +/- 1 % time delay
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1504008EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1504008EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications
  • CSA
  • C-tick
  • GL
  • UL
  • GOST
Standards EN/IEC 60255-6
Non-Dissipating Shock Wave
  • 4 kV IEC 60255-5
  • 4 kV IEC 60664-1
  • 4 kV IEC 61000-4-5
Dielectric Test Voltage
  • 2 kV AC 50 Hz, 1 min IEC 60255-5
  • 2 kV AC 50 Hz, 1 min IEC 60664-1
Electromagnetic Compatibility
  • emission standard for industrial environments EN/IEC 61000-6-4
  • emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3
  • immunity for industrial environments NF EN/IEC 61000-6-2
Shock Resistance 5 gn IEC 60068-2-27
Ambient Air Temperature For Operation -20-50 °C
Vibration Resistance
  • 0.35 mm 5-57.6 Hz)IEC 60068-2-6
  • 1 gn 57.6-150 Hz)IEC 60255-21-1
Ip Degree Of Protection
  • IP20 IEC 60529 terminals)
  • IP30 IEC 60529 casing)
Pollution Degree 3 IEC 60664-1
Directives
  • 73/23/EEC - low voltage directive
  • 89/336/EEC - electromagnetic compatibility
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 95-95 % 55-55 °C IEC 60068-2-30