This Harmony RM17-J control relay allows monitoring of current control in 3-phase networks. This modular 3-phase control relay is ideal for monitoring of electrical values and current variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
Brand: Schneider Electric
Add to Quote CatalogueMinimum Switching Current | 10 mA 5 V DC |
---|---|
Range Of Product | Harmony Control Relays |
Measurement Range | 2...20 A current |
Switching Capacity In Va | 1250 VA |
Product Or Component Type | current control relay |
Utilisation Category |
|
Relay Name | RM17JC |
Contacts Type And Composition | 1 C/O |
Relay Type | current control relay |
Time Delay Type | without |
Relay Monitored Parameters | overcurrent detection |
Maximum Power Consumption In Va | 3 VA |
Warranty | 18 months |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz +/- 10 % |
Polarity | yes DC |
Maximum Measuring Cycle | 30 ms measurement cycle as true rms value |
Control Circuit Voltage Limits | 15 % + 10 % Un |
Hysteresis | 15-15 % fixed threshold setting |
Insulation Resistance |
|
Measurement Error |
|
Operating Rate | <= 360 operations/hour full load |
Output Contacts | 1 C/O |
Contacts Material | cadmium free |
Marking |
|
Response Time | < 200 ms (in the event of a fault) |
Operating Position | any position without derating |
Input Current |
|
Net Weight | 0.13 kg |
Threshold Setting | 10...100 % |
Maximum Switching Voltage | 250 V AC/DC |
Connections - Terminals |
|
[Ui] Rated Insulation Voltage | 400 V IEC 60664-1 |
Overvoltage Category | III IEC 60664-1 |
Insulation | between supply and measurement |
Supply Voltage Limits | 20.4-264 V AC/DC |
Mounting Support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
Nominal Output Current | 5 A |
Local Signalling |
|
Mechanical Durability | 30000000 cycles |
Housing Material | self-extinguishing plastic |
Control Circuit Frequency | 40...70 Hz sinusoidal |
Measurement Accuracy | +/- 10 % of the full scale value |
Width | 17.5 mm |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Maximum Power Consumption In W | 1 W |
Electrical Durability | 100000 cycles |
Run-Up Delay At Power-Up | 0.5 s |
Repeat Accuracy | +/- 0.5 % input and measurement circuit |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1504008EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI1504008EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Product Certifications |
|
Standards | EN/IEC 60255-6 |
Immunity To Microbreaks | 10 ms |
Non-Dissipating Shock Wave | 4 kV |
Dielectric Test Voltage | 2 kV AC 50 Hz |
Electromagnetic Compatibility |
|
Shock Resistance | 15 gn 11 ms IEC 60255-21-1 |
Ambient Air Temperature For Operation | -20-50 °C |
Vibration Resistance |
|
Ip Degree Of Protection |
|
Pollution Degree | 3 IEC 60664-1 |
Ambient Air Temperature For Storage | -40-70 °C |
Relative Humidity | 95-95 % 55-55 °C IEC 60068-2-30 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366