Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
RLF36080CU31A – Circuit breaker, PowerPacT R, 800A, 3 pole, 600VAC, 50kA, busbar, Micrologic 3.0, 100%
RLF36080CU31A
Circuit breaker, PowerPacT R, 800A, 3 pole, 600VAC, 50kA, busbar, Micrologic 3.0, 100%

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. The circuit breaker has a continuous current rating of 100%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Or Component Type circuit breaker
Product Name PowerPact R
Device Application distribution
Range PowerPact
Warranty 18 months
Circuit Breaker Application HACR rated
Mounting Mode unit mount busbar)
Network Frequency 50/60 Hz
Wire Stripping Length 35 mm
Terminal Identifier AL2500RK
Line Rated Current 800-800 A
Utilisation Category category A
[Ics] Rated Service Breaking Capacity
  • 65 kA 240 V AC 50/60 Hz IEC 60947-2
  • 45 kA 380/415 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology electronic, standard, MicroLogic 3.0, LI
Trip Unit Name MicroLogic 3.0
Height 16.24 in
Continuous Current Rating 100 %
Breaking Capacity
  • AIR 125 kA 240 V AC 50/60 Hz UL 489
  • AIR 100 kA 480 V AC 50/60 Hz UL 489
  • AIR 50 kA 600 V AC 50/60 Hz UL 489
  • Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2
  • Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ui] Rated Insulation Voltage 750 V IEC 60947-2
Suitability For Isolation yes IEC 60947-2
[Ue] Rated Operational Voltage 600 V AC 50/60 Hz UL 489
Tightening Torque
  • 62-62 N.m 50-400 mm² (AWG 1/0...750 kcmil)
  • 62-62 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
Mounting Support busbar
Breaking Capacity Code L
Poles Description 3P
Local Signalling alarm 1 LED yellow)long-time pick up)
Quantity Per Set 1
Number Of Slots
  • 2 auxiliary switch OF plug-in)
  • 1 alarm switch SD plug-in)
  • 1 voltage release MN or MX plug-in)
Awg Gauge AWG 3/0...750 kcmil aluminium/copper
Width 16.53 in
Electrical Connection
  • busbar connection line
  • busbar connection load
Depth 14.49 in
Net Weight 52 lb(US)
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
Control Type operating handle
Ambient Air Temperature For Operation -25-70 °C
Pollution Degree 3 IEC 60947-1
Ambient Air Temperature For Storage -50-85 °C
Standards
  • UL
  • CSA
  • NEMA
  • NMX J-266
  • IEC 60947-2
Quality Labels CE
Product Certifications
  • UL
  • CSA
  • NOM
Operating Altitude
  • < 6561.68 ft (2000 m) without derating
  • 13123.36 ft (4000 m) with derating
Ip Degree Of Protection IP40
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews