PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 5.0A trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. The circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Or Component Type circuit breaker
Product Name PowerPact R
Device Application distribution
Range PowerPact
Warranty 18 months
Circuit Breaker Application HACR rated
Mounting Mode unit mount busbar)
Network Frequency 50/60 Hz
Wire Stripping Length 35 mm
Terminal Identifier AL2500RK
Utilisation Category category A
Line Rated Current 600-600 A
[Ics] Rated Service Breaking Capacity
  • 65 kA 240 V AC 50/60 Hz IEC 60947-2
  • 45 kA 380/415 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology electronic, ammeter, MicroLogic 5.0 A, LSI
Trip Unit Name MicroLogic 5.0 A
Height 16.24 in
Continuous Current Rating 80 %
Breaking Capacity
  • AIR 125 kA 240 V AC 50/60 Hz UL 489
  • AIR 100 kA 480 V AC 50/60 Hz UL 489
  • AIR 50 kA 600 V AC 50/60 Hz UL 489
  • Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2
  • Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ui] Rated Insulation Voltage 750 V IEC 60947-2
Suitability For Isolation yes IEC 60947-2
[Ue] Rated Operational Voltage 600 V AC 50/60 Hz UL 489
Tightening Torque
  • 62-62 N.m 50-400 mm² (AWG 1/0...750 kcmil)
  • 62-62 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
Mounting Support busbar
Breaking Capacity Code L
Poles Description 3P
Local Signalling
  • alarm 1 LED yellow)long-time pick up)
  • 1 LED red)long-time pick up)
  • trip causes 1 LED red)
  • 1 LED red)digital ammeter)
  • phase-loading LED green)load balancing)
Quantity Per Set 1
Number Of Slots
  • 2 auxiliary switch OF plug-in)
  • 1 alarm switch SD plug-in)
  • 1 voltage release MN or MX plug-in)
Awg Gauge AWG 3/0...750 kcmil aluminium/copper
Width 16.53 in
Electrical Connection
  • busbar connection line
  • busbar connection load
Depth 14.49 in
Net Weight 52 lb(US)
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
Control Type operating handle
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile ENVEOLI2206034EN
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP2206034EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Eu Rohs Directive Compliant
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Halogen Content Performance Halogen free plastic parts product
Ambient Air Temperature For Operation -25-70 °C
Pollution Degree 3 IEC 60947-1
Ambient Air Temperature For Storage -50-85 °C
Standards
  • UL
  • CSA
  • NEMA
  • NMX J-266
  • IEC 60947-2
Quality Labels CE
Product Certifications
  • UL
  • CSA
  • NOM
Operating Altitude
  • < 6561.68 ft (2000 m) without derating
  • 13123.36 ft (4000 m) with derating
Ip Degree Of Protection IP40
Documents