This modular timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Range Of Product Harmony Timer Relays
Software Designation Zelio NFC downloadable from Google Play store)
Product Or Component Type multifunction relay
Operating System Android
Software Version V4.4 and above
Device Short Name RENF22
Power Consumption In W
  • 1.5 W 240 V DC
  • 0.6 W 24 V DC
Contacts Type And Composition
  • 2 C/O timed contact, cadmium free
  • 1 C/O timed and instantaneous contact, cadmium free
Discrete Output Type relay
Setting Accuracy Of Time Delay
  • +/- 1 % 1...999 h 25 °C
  • +/- 2 % 1 h 25 °C
  • +/- 20 ms 100 ms...10 s 25 °C
Creepage Distance 4 kV/3 IEC 60664-1
Maximum Delay Response 100 ms
Insulation Resistance 100 MOhm 500 V DC IEC 60664-1
Nominal Power 0.0002 mW
Power Consumption In Va 3-3 VA 240 V AC
Switching Capacity In Va 2000 VA
Minimum Pulse Duration
  • 100 ms with load in parallel
  • 60 ms no-load
Maximum Switching Current 8 A
Function Available
  • A- Power on-delay relay-2 C/O
  • Ac- On-delay and off-delay relay w/ control signal-2 C/O
  • Ad- Pulse delayed relay w/ control signal-2 C/O
  • Ah- Pulse delayed relay (single cycle) w/ control signal-2 C/O
  • Ak- Asymmetrical on-delay and off -delay relay w/ control signal-2 C/O
  • At- Power on-delay relay w/ pause/summation (Y1)-2 C/O
  • B- Single interval relay w/ control signal-2 C/O
  • Bw- Double interval relay w/ control signal-2 C/O
  • C- Off-delay relay w/ control signal-2 C/O
  • D- Symmetrical flashing relay (starting pulse-off)-2 C/O
  • Di- Symmetrical flashing relay (starting pulse-on)-2 C/O
  • Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O
  • Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O
  • H- Interval relay-2 C/O
  • Ht- Interval relay w/ pause/summation (Y1)-2 C/O
  • Li- Asymmetrical flashing relay (starting pulse-on)-2 C/O
  • Lt- Asymmetrical fl ashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O
  • Lit- Asymmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O
  • N- Safe-guard relay-2 C/O
  • O- Delayed Safe-guard relay-2 C/O
  • P- Pulse delayed relay w/ fixed pulse length-2 C/O
  • Pt- Pulse delayed relay w/ fixed pulse length and pause/summation-2 C/O
  • Qt- Star-delta relay (2 CO outputs w/ split common)-2 C/O
  • Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (Y1)-2 C/O
  • TI- Bistable relay w/ control signal on-2 C/O
  • Tt- Retriggerable bistable relay w/ control signal on-2 C/O
  • W- Interval relay w/ control signal off-2 C/O
  • L- Asymmetrical flashing relay (starting pulse-off)-2 C/O
Operating Distance 10 mm
Voltage Range 0.85...1.1 Un
Local Signalling
  • Un, green LED steady)power ON
  • R1, amber LED steady)relay energised
  • R2, amber LED steady)relay energised
  • pairing, green LED steady)communication status
  • Un, green LED fast blinking)diagnosis mode
  • R1, amber LED blinking)timing in progress
  • R2, amber LED blinking)timing in progress
Net Weight 0.0904 kg
[Uimp] Rated Impulse Withstand Voltage 5 kV 1.2/50 µs IEC 60664-1
Voltage Drift +/- 0.2 %/V
Reset Time 120 ms on de-energisation
Maximum Switching Voltage 250 V
Connections - Terminals
  • screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Us] Rated Supply Voltage 24...240 V AC/DC
Temperature Drift +/- 0.05 %/°C
Time Delay Range 0.1 s...999 h
Minimum Switching Current 10 mA 5 V
Overvoltage Category III IEC 60664-1
Input Voltage <= 2.4 V
Mounting Support 35 mm DIN rail conforming to EN/IEC 60715
Nominal Output Current 8 A
Response Time 2 s
Electrical Durability 100000 cycles for resistive load, 8 A at 250 V, AC
Mechanical Durability 10000000 cycles
Housing Material self-extinguishing
Safety Reliability Data MTTFd = 227.5 years 100 % duty cycle continuous operating condition at 30 °C
Mounting Position any position
Width 22.5 mm
Time Delay Type
  • power on-delay
  • on-delay and off-delay
  • pulse delay
  • asymmetrical on-delay and off-delay
  • interval
  • off-delay
  • symmetrical flashing
  • safe-guard
  • star-delta
  • asymmetrical flashing
  • bistable
Product Compatibility NFC enabled mobile device
Tightening Torque
  • 0.6-1 N.m IEC 60947-1
  • 5.3-8.8 lbf.in IEC 60947-1
Maximum Operating Frequency 13.56 MHz
Supply Frequency 50...60 Hz +/- 5 %
Repeat Accuracy
  • +/- 0.2 % 10 s...999 h
  • +/- 0.5 % 100 ms...10 s
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1401008EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation X
Circularity Profile ENVEOLI1401008EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications
  • CE
  • CSA
  • KC
  • UL
  • CCC
  • EAC
  • DNV-GL
Ambient Air Temperature For Operation -20-60 °C
Standards
  • EN 61000-6-1
  • EN 61000-6-2
  • EN 61000-6-4
  • EN 61812-1
  • EN 61000-6-3
Immunity To Microbreaks 10 ms
Electromagnetic Compatibility
  • electrostatic discharge immunity test 6 kV contact discharge)level 3 EN/IEC 61000-4-2
  • electrostatic discharge immunity test 8 kV air discharge)level 3 EN/IEC 61000-4-2
  • fast transients immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4
  • fast transients immunity test 2 kV direct contact)level 3 IEC 61000-4-4
  • surge immunity test 1 kV differential mode)level 3 IEC 61000-4-5
  • surge immunity test 2 kV common mode)level 3 IEC 61000-4-5
  • radiated radio-frequency electromagnetic field immunity test 10 V 0.15...80 MHz)level 3 IEC 61000-4-6
  • electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3
  • immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11
  • immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11
  • radiated emissionclass B EN 55022
  • conducted emissionclass A EN 55022
  • electromagnetic field immunity test 3 V/m 1.4 GHz...2 GHz)level 2 IEC 61000-4-3
  • electromagnetic field immunity test 1 V/m 2...2.7 GHz)level 1 IEC 61000-4-3
Dielectric Strength
  • 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply with basic insulation
  • basic insulation
Shock Resistance
  • 15 gn not operating 11 ms IEC 60068-2-27
  • 5 gn in operation 11 ms IEC 60068-2-27
Vibration Resistance 20 m/s² 10-150 Hz)IEC 60068-2-6
Pollution Degree 3 IEC 60664-1
Directives
  • 2014/35/EU - low voltage directive
  • 2014/53/EU - radio equipment directive
  • 2014/30/EU - electromagnetic compatibility
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 95-95 % 25-55 °C
Ip Degree Of Protection
  • housing IP40 IEC 60529
  • front face IP40 IEC 60529
  • terminals IP20 IEC 60529
Documents