RE48ATM12MW – Modular timing relay, Harmony, 5A, 2CO, 0.02 s…300h, on delay, 24…240V AC DC
RE48ATM12MW
Modular timing relay, Harmony, 5A, 2CO, 0.02 s...300h, on delay, 24...240V AC DC

This Harmony RE48 timing relay can be set between 0.02 seconds and 300 hours, has an output rating of 5A, is 48mm wide and can be supplied with 24V to 240V AC. It is a plug-in device, meaning it is quick and easy to install with the need for tools. It also offers a sealable cover, simple and precise settings with rotary trimmers. It is designed for both panel mooting or socket plug in, this gives more flexibility in designing installations and stocking spares. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Voltage Range
  • 0.85...1.1 Us AC
  • 0.9...1.1 Us DC
Contacts Type And Composition 2 C/O timed contacts, AgNi (cadmium free)
Discrete Output Type relay
Range Of Product Harmony Timer Relays
Product Or Component Type single function relay
Component Name RE48
[Us] Rated Supply Voltage 24...240 V AC/DC 50/60 Hz
Time Delay Range
  • 5...300 h
  • 2...120 min
  • 0.5...30 h
  • 0.2...12 h
  • 0.2...12 min
  • 0.2...12 s
  • 0.5...30 min
  • 2...120 h
  • 2...120 s
  • 0.02...1.2 s
  • 0.5...30 s
  • 5...300 s
  • 0.05...3 s
  • 5...300 min
Line Rated Current 5 A
Electrical Connection plug-in sub-base 8
Time Delay Type power on-delay
Warranty 18 months
Output Voltage
  • 240 V 5 A AC-12
  • 30 V 2 A DC-13
  • 240 V 1.5 A AC-15
Power Consumption In W
  • 0.5 W 24 V
  • 1.7 W 240 V
Setting Accuracy Of Time Delay +/- 5 % of full scale 25 °C IEC 61812-1
Control Type selector switch front panel
Mounting Support
  • panel mounted: system supplied with the product
  • base mounted: socket
Temperature Drift +/- 0.02 %/°C of the maximum setting value IEC 61812-1
Pick Up Duration 55 ms
Maximum Switching Current 5 A
Marking CE
Product Front Plate Size 48 x 48 mm
Net Weight 0.14 kg
Minimum Pulse Duration 20 ms
Reset Time 25 ms on de-energisation
Power Consumption In Va
  • 1.1 VA 24 V
  • 4.8 VA 240 V
Maximum Switching Voltage 250 V AC/DC
Surge Withstand
  • 1 kV differential mode IEC 61000-4-5 level 3
  • 2 kV common mode IEC 61000-4-5 level 3
Voltage Drift
  • +/- 0.2 %/V of the maximum setting value 48...240 V
  • +/- 1 %/V of the maximum setting value 24...48 V
Electrical Durability 100000 cycles
Minimum Switching Current 100 mA
Local Signalling
  • for output relay state 1 LED (yellow)
  • for flashing: relay energised timing in progress LED indicator (green)
  • for on steady: relay energised, no timing in progress LED indicator (green)
Mechanical Durability 30000000 cycles
On-Load Factor 100 %
Housing Material self-extinguishing
Breaking Capacity 1250 VA
Repeat Accuracy +/- 0.2 % of the maximum setting value IEC 61812-1
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1512002EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation X
Circularity Profile ENVEOLI1512002EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications
  • UL
  • cULus
  • C-tick
  • CSA
Ambient Air Temperature For Operation -20-50 °C
Resistance To Electromagnetic Fields 10 V/m 26 MHz to 1 GHz IEC 61000-4-3 level 3
Standards
  • 73/23/EEC
  • 93/68/EEC
  • EN 50082-1/2
  • 89/336/EEC
  • EN 50081-1/2
  • IEC 61812-1
  • IEC 60669-2-3
Disturbance Radiated/Conducted class B 0.15...30 MHz EN 55022 (EN 55011 group 1)
Immunity To Microbreaks 10 ms
Protection Against Electric Shocks
  • 4 kV class III IEC 60664-1
  • 4 kV class III IEC 61812-1
Immunity To Voltage Dips
  • 30 % / 10 ms EN/IEC 61000-4-11
  • 60 % / 100 ms EN/IEC 61000-4-11
  • 95 % / 5 s EN/IEC 61000-4-11
Vibration Resistance 0.35 mm 10-55 Hz)IEC 60068-2-6
Ip Degree Of Protection
  • IP40 IEC 60529 housing)
  • IP50 IEC 60529 front face)
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 93-93 % without condensation IEC 60068-2-3
Resistance To Electrostatic Discharge
  • 6 kV in contact EN/IEC 61000-4-2 level 3
  • 8 kV in air EN/IEC 61000-4-2 level 3
Humidity Drift +/- 0.05 %/%RH of the maximum setting value IEC 61812-1
Immunity To Radioelectric Fields 10 V 0.15...80 MHz)EN/IEC 61000-4-6 level 3
Resistance To Fast Transients
  • 2 kV EN/IEC 61000-4-4 level 4 capacitive connecting clip)
  • 4 kV EN/IEC 61000-4-4 level 4 direct)
Dielectric Strength 1 kV 1 mA/1 minute IEC 61812-1