QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO load centers feature plated copper bus, providing superior performance and durability. This single phase QO load center has fixed mains and is rated at 100 A at 120/240 VAC. This QO load center has a 10 kA breaking capacity. This system provides 6 spaces in a NEMA 1 enclosure. This load center has a surface cover. The lugs will accept 8 AWG to 1 AWG copper or aluminum wire. The load center is 12.56 inches tall, 8.90 inches wide and 3.74 inches deep. The load center is CSA certified.
Brand: Schneider Electric
Add to Quote CatalogueCover Type | surface cover |
---|---|
Range Of Product | QO |
Product Or Component Type | Load Center |
Warranty | 18 months |
Height | 319 mm |
Short-Circuit Current | 10 kA |
Number Of Tandem Circuit Breakers | 0 |
Tightening Torque |
|
[Ue] Rated Operational Voltage | 120/240 V AC |
Material | tin plated aluminium busbar |
Surface Finish | baked enamel Gray |
Line Rated Current | 100 A |
Enclosure Material | welded sheet steel |
Wiring Configuration | 3-wire |
Width | 226 mm |
Electrical Connection | lugs |
Depth | 95 mm |
Number Of Circuits | 6 |
Number Of Spaces | 6 |
Load Center Type | Fixed Mains (lugs) |
Device Composition | grounding bar (ordered separately) |
Phase | 1 phase |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1406009EN |
Sustainable Offer Status | Green Premium product |
Eu Rohs Directive | Compliant |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Product Certifications | cULus |
Nema Degree Of Protection | NEMA 1 indoor |
Ambient Air Temperature For Operation |
|