QO Load Centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO Load Centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO Load Centers feature plated copper bus, providing superior performance and durability. This QO Load Center contains a convertible main and is rated at 225 A and 3 phase. This system provides 42 spaces in a NEMA 3R enclosure. QO Load Centers enable the use of a full complement of accessories. This 3 phase load center has 42 spaces and 42 circuits. This system provides a 225A convertible main breaker in a NEMA 3R enclosure. It also includes a QDL circuit breaker and is UL rated.
Brand: Schneider Electric
Add to Quote CatalogueRange Of Product | QO |
---|---|
Product Or Component Type | Load Center |
Enclosure Type | weatherproof enclosure |
Cover Type | surface cover |
Warranty | 18 months |
Height | 1000 mm |
[Ue] Rated Operational Voltage |
|
Electrical Connection | lugs |
Number Of Circuits | 42 |
Number Of Spaces | 42 |
Phase | 3 phase |
Short-Circuit Current | 25 kA |
Number Of Tandem Circuit Breakers | 0 |
Material | tin plated copper busbar |
Surface Finish | baked enamel Gray |
Line Rated Current | 225 A |
Enclosure Material | welded galvannealed steel |
Awg Gauge | AWG 4...300 kcmil aluminium/copper |
Width | 375 mm |
Wiring Configuration |
|
Load Center Type | main breaker |
Device Composition | grounding bar (ordered separately) |
Box Number | 14R |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP2101006 |
Sustainable Offer Status | Green Premium product |
Toxic Heavy Metal Free | Yes |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
China Rohs Regulation | Pro-active China RoHS declaration (out of China RoHS legal scope) |
Eu Rohs Directive | Compliant |
Product Certifications | UL Listed |
Nema Degree Of Protection | NEMA 3R outdoor |
Ambient Air Temperature For Operation |
|
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366