PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 5.0A trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Brand: Schneider Electric
Add to Quote CatalogueProduct Or Component Type | circuit breaker |
---|---|
Product Name | PowerPact P |
Range | PowerPact |
Device Application | distribution |
Warranty | 18 months |
Mounting Mode | unit mount lug) |
Network Frequency | 50/60 Hz |
Terminal Identifier | AL800M23K |
[Ics] Rated Service Breaking Capacity |
|
Trip Unit Technology | electronic, ammeter, MicroLogic 5.0 A, LSI |
Trip Unit Name | MicroLogic 5.0 A |
Height | 12.86 in |
[Ue] Rated Operational Voltage | 600 V AC 50/60 Hz UL 489 |
Tightening Torque |
|
Mounting Support | lug |
Breaking Capacity Code | J |
Local Signalling |
|
Number Of Slots |
|
Electrical Connection |
|
Net Weight | 32 lb(US) |
[Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
Control Type | toggle |
Circuit Breaker Application | HACR rated |
Wire Stripping Length | 25 mm |
Line Rated Current | 800-800 A |
Long Time Pick-Up Adjustment Range | 0.4...1 x Ir |
Continuous Current Rating | 80 % |
Breaking Capacity |
|
[Ui] Rated Insulation Voltage | 750 V IEC 60947-2 |
Poles Description | 3P |
Quantity Per Set | 1 |
Awg Gauge | 3 x AWG 3/0...500 kcmil aluminium/copper |
Width | 8.27 in |
Depth | 8.05 in |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP2206033EN |
Sustainable Offer Status | Green Premium product |
Pvc Free | Yes |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Circularity Profile | ENVEOLI2206033EN |
Eu Rohs Directive | Compliant |
Ambient Air Temperature For Operation | -2-70 °C |
Standards |
|
Product Certifications |
|
Ip Degree Of Protection | front cover IP40 |
Pollution Degree | 3 IEC 60947-1 |
Ambient Air Temperature For Storage | -50-85 °C |
Quality Labels | CE |
Operating Altitude |
|
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366