Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
NF8430L1C – Panelboard interior, NF, main lugs, 125A, Cu bus, 30 pole spaces, 3 phase, 4 wire, 480Y/277 VAC bolt on
NF8430L1C
Panelboard interior, NF, main lugs, 125A, Cu bus, 30 pole spaces, 3 phase, 4 wire, 480Y/277 VAC bolt on

NF Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These interiors provide protection for commercial and industrial applications. NF Panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. NF Panelboards are field convertible to top or bottom feed. NF Panelboards are convertible from main lug to main breaker. NF Panelboards can provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. The main lugs are rated at 100A 480Y/277 VAC 3 phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 30 spaces and has a copper bus bar. Interior is for EDB, EDG, and EDJ branch circuit breakers. Line lug connections will accept 6 AWG to 300 kcmil copper or aluminum wire. The interior is 27 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Circuit Breaker Type EDB/EDG/EDJ
Load Center Type main lugs
Material copper
Warranty 18 months
Height 27 in
Connections - Terminals
  • lug line AWG 6...300 kcmil aluminium/copper
  • lug neutral AWG 6...300 kcmil aluminium/copper
Enclosure Nominal Depth 5.65 in NEMA 1
Tightening Torque
  • 4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0)
  • 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0)
  • 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil)
  • 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil)
  • 31.07-31.07 N.m 107.2-152 mm² (AWG 4...300 kcmil)
Line Rated Current 100 A
[Iu] Rated Interrupted Current 65 kA
Wiring Configuration 4-wire
Width 10.44 in
Number Of Spaces 30
Enclosure Nominal Height 59 in
Phase 3 phase
Enclosure Nominal Width 8.625 in
[Ue] Rated Operational Voltage 480Y/277 V AC
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information Yes
Mercury Free Yes
Eu Rohs Directive Compliant
California Proposition 65 WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Standards
  • UL 67
  • CSA C22.2
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews