Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
NF430L6C – Panelboard interior, NF, main lugs, 600A, Cu bus, Al neutral assembly, 30 pole spaces, 3 phase, 4 wire, 600Y/347VAC max
NF430L6C
Panelboard interior, NF, main lugs, 600A, Cu bus, Al neutral assembly, 30 pole spaces, 3 phase, 4 wire, 600Y/347VAC max

NF Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These interiors provide protection for commercial and industrial applications. NF Panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. NF Panelboards are field convertible to top or bottom feed. NF Panelboards are convertible from main lug to main breaker. NF Panelboards can provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. The main lugs are rated at 600A 600Y/347 VAC 3 phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 30 spaces and has a copper bus bar. Interior is for EDB, EDG, and EDJ branch circuit breakers. Lug connections will accept 1/0 AWG to 750 kcmil aluminum wire. The interior is 21 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Circuit Breaker Type EDB/EDG/EDJ
Material copper
Load Center Type main lugs
Warranty 18 months
Height 46 in
Connections - Terminals
  • lug line AWG 1/0...750 kcmil aluminium
  • lug neutral AWG 1/0...750 kcmil aluminium
Tightening Torque
  • 31.07-33.90 N.m 53.48-380 mm² (AWG 1/0...750 kcmil)
  • 31.07-33.90 N.m 53.48-177.3 mm² (AWG 1/0...350 kcmil)
  • 62.14-62.14 N.m 53.48-380 mm² (AWG 1/0...750 kcmil)
  • 62.14-62.14 N.m 53.48-152 mm² (AWG 1/0...300 kcmil)
  • 42.37-42.37 N.m 53.48-380 mm² (AWG 1/0...750 kcmil)
  • 42.37-42.37 N.m 53.48-152 mm² (AWG 1/0...300 kcmil)
[Iu] Rated Interrupted Current 65 kA
Number Of Spaces 30
Enclosure Nominal Height 50 in
Phase 3 phase
Net Weight 14.06 kg
Enclosure Nominal Depth
  • 5.75 in NEMA 1
  • 6.5 in NEMA 3R/5/12
Line Rated Current 600 A
Width 10.44 in
Wiring Configuration 4-wire
Enclosure Nominal Width 20 in
[Ue] Rated Operational Voltage 600Y/347 V AC
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1404020EN
Sustainable Offer Status Green Premium product
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive Compliant
Standards
  • UL 67
  • CSA C22.2
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews