METSEION92030 – PowerLogic™ ION9000 meter, DIN mount, no display, HW kit
METSEION92030
PowerLogic™ ION9000 meter, DIN mount, no display, HW kit

The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs of 1 A, 5 A; current class 2, 10, 20 A; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting or panel mounting (with back to back adapter) transducer, plus 2 display options, further enhance the flexibility and adaptability of the ION9000.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Or Component Type energy and power quality meter
Range PowerLogic
Device Application
  • power monitoring
  • WAGES metering
  • Net metering
  • medium voltage
  • high voltage
Device Short Name ION92030
Metering Type
  • demand current I1, I2, I3, I4, I5
  • peak demand currents
  • demand power P, Q, S
  • peak demand power PM, QM, SM
  • calculated active and reactive energy (+/- W.h, +/- VAR.h)
Network Frequency
  • 50 Hz
  • 60 Hz
[Us] Rated Supply Voltage
  • 90...480 V AC 45...66 Hz +/- 10 %
  • 90...120 V AC 400 Hz +/- 10 %
  • 110...480 V DC +/- 15 %
Communication Port Support 2 RS485 removable screw terminal block
Power Quality Analysis
  • EN 50160 compliance checking
  • IEEE 519 harmonic limit
  • IEC 61000-4-30 class A compliance reporting
  • IEEE 519 compliance reporting
  • waveform capture
  • total demand distortion
  • total harmonic distortion
  • up to the 63rd harmonic
  • up to the 127th harmonic with software
  • disturbance direction detection
  • dip, swell and transient
  • half cycle data acquisition
  • transient detection (20 µs)
Height 160 mm
Measurement Voltage
  • 57-400 V AC 42...69 Hz between phase and neutral
  • 100-690 V AC 42...69 Hz between phases
Sampling Rate 1024 samples/cycle
Memory Capacity 2 GB
Number Of Outputs
  • 4 digital
  • 2 form C relay
Type Of Measurement
  • voltage sags and swells
  • current sags and swells
  • voltage
  • current
  • frequency
  • active and reactive power total
  • apparent power total
  • active and reactive power per phase
  • apparent power per phase
  • power factor total
  • power factor per phase
  • active and reactive energy
  • apparent energy
  • harmonic distorsion (I THD & U THD)
Communication Port Protocol
  • Modbus RTU 2400...115200 bps - 2-wire
  • ION 2400...115200 bps - 2-wire
  • DNP3 2400...115200 bps - 2-wire
  • Modbus TCP 10/100 Mbit/s
  • ION TCP 10/100 Mbit/s
  • DNP3 TCP 10/100 Mbit/s
  • IEC 61850
  • Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
  • DHCP
  • DNS
  • DLMS
Frequency Measurement Range 20-450 Hz
Communication Service
  • compliant reports
  • power quality summary
  • energy report
  • EcoStruxure Power Events Analysis
  • SMTP e-mail notification
  • SNMP
Ride-Through Time
  • 100 ms 6 cycles at 60 Hz 120 V AC typical
  • 400 ms 24 cycles at 60 Hz 240 V AC typical
  • 1200 ms 72 cycles at 60 Hz 480 V AC typical
Port Ethernet 10/100BASE-TX 2 RJ45
Power Consumption In Va 38 VA 480 V AC
Net Weight 1.5 kg
Tamperproof Of Settings protected by sealable cover
Measurement Current 0.01-20 A
Electrical Insulation Class class III EN/IEC 62052-11
Number Of Inputs 8 digital 30 V AC/60 V DC
Time Synchronisation Protocol
  • GPS
  • IRIG-B
  • NTP
  • SNTP
  • PTP
Measurement Accuracy
  • voltage +/- 0.1 %
  • current +/- 0.1 %
Ethernet Service
  • DHCP client
  • Device Profile Web Services (DPWS)
  • Rapid Scanning Tree Protocol (RSTP)
  • FTP/HTTP/HTTPS
Mounting Support DIN rail
Communication Gateway Ethernet/serial
Poles Description 3P + N + E
Data Recording
  • time stamping
  • min/max of instantaneous values
  • user-definable data logs
  • continuous logging or snapshot
  • trending/forecasting
  • event logs
  • alarm logs
  • configuration change
  • power outage
  • user login/logout
  • data logs
  • GPS synchronisation
  • sequence of event recording
Line Rated Current
  • 1 A
  • 5 A
Cybersecurity
  • Syslog protocol support
  • robust security logs
  • port hardening
  • enable/disable communication ports
  • hardware metrology lock
Isolation Voltage
  • III400-690 V conforming to EN 61010-1:ed. 3
  • III347-600 V conforming to UL 61010-1:ed. 3
  • III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Analogue Input Type
  • voltage 5 MOhm)
  • 5 external CT 0.3 mOhm)
Web Services
  • viewing of captured waveform
  • web page
  • pass/fail report for IEEE 519
  • pass/fail report for EN 50160
  • ITIC (CBEMA) curve
  • SEMI curve
  • NEMA motor derating curve
  • alarm notification by e-mail
  • TLS 1.2
  • push historical data via mail
Width 160 mm
Display Type Without Display
Depth 135.3 mm
Accuracy Class
  • class 0.1S active energy IEC 62053-22
  • class 0.1 active energy IEC 61557-12
  • class 0.1 active energy ANSI C12.20
  • class 0.5S reactive energy IEC 62053-24
  • class 0.1 current IEC 61557-12
  • class 0.1 voltage IEC 61557-12
  • class 0.1 active power IEC 61557-12
  • class 0.5 power factor IEC 61557-12
Maximum Power Consumption In Va 80 VA 480 V AC
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1801009EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1801009EN
Eu Rohs Directive Compliant
Ambient Air Temperature For Operation -25-70 °C
Standards
  • ANSI C12.20
  • ANSI C37.90.1
  • IEC 61000-4-15
  • IEC 61000-4-30
  • IEC 61010-1
  • IEC 61326-1
  • IEC 61557-12
  • IEC 61850
  • IEC 62052-11
  • IEC 62052-31
  • IEC 62053-22
  • IEC 62053-23
  • IEC 62053-24
  • IEC 62586
  • UL 61010-1
Degree Of Protection UL type 12, front
Electromagnetic Compatibility
  • EMC immunity IEC 62052-11
  • EMC immunity IEC 61326-1
  • EMC immunity IEC 61000-6-5
  • electrostatic discharge immunity test IEC 61000-4-2
  • immunity to radiated fields IEC 61000-4-3
  • immunity to fast transients IEC 61000-4-4
  • surge immunity test IEC 61000-4-5
  • immunity to conducted disturbances IEC 61000-4-6
  • immunity to magnetic fields at network frequency IEC 61000-4-8
  • immunity to conducted disturbances 2...150 kHz CLC/TR 50579
  • voltage dips and interruptions immunity test IEC 61000-4-11
  • immunity to impulse waves IEC 61000-4-12
  • conducted and radiated emissions EN 55011
  • conducted and radiated emissionsclass B EN 55032
  • conducted and radiated emissionsclass B FCC part 15
  • conducted and radiated emissionsclass B ICES-003
  • surge withstand ANSI C37.90.1
  • surge withstand IEEE C37.90.1
Ambient Air Temperature For Storage -40-85 °C
Relative Humidity 5-95 %
Quality Labels
  • ISO 9001
  • ISO 14000
Ip Degree Of Protection
  • front IP65
  • rear IP30
Operating Altitude 0...9842.52 ft (0...3000 m)
Installation Category III
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews