METSEION7400
PowerLogic ION7400 Panel mount meter - display - optical port and 2 pulse

PowerLogic ION7400 utility feeder power meters combine capabilities not typically available in compact meters. They offers a hight flexibility and usability, along with accurate 3-phase energy and power measurements with data logging. Use Power Monitoring Expert software for data analysis or share operation data with SCADA systems through multiple communication channels and protocols. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 16 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 90-415 VAC / 110-415 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. Panel mounting (1/4 DIN) with integrated display.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Or Component Type power meter
Product Name PowerLogic ION7400
Range PowerLogic
Device Short Name ION7400
Communication Network Type IPv6 (internet protocol)
Network Frequency
  • 50 Hz
  • 60 Hz
Communication Port Support
  • ETHERNET
  • screw terminal block RS485
  • optical probe fiber optic
  • mini B USB USB
Power Quality Analysis
  • EN 50160 2010 compliance report
  • IEEE 519 2014 compliance report
  • IEC 61000-4-30 class S power quality measurement
  • up to the 63rd harmonic
  • harmonic distortion
  • waveform capture
  • voltage sag and swell detection
  • programmablity (logic and math functions)
  • IEC 62586 power quality monitoring
  • IEC 61000-4-15 flicker
  • disturbance direction detection
Height 112 mm
Measurement Voltage
  • 57-400 V AC 42...69 Hz between phase and neutral
  • 100-690 V AC 42...69 Hz between phases
Sampling Rate 256 samples/cycle
Standards
  • IEC 62053-22
  • IEC 62052-11
  • IEC 62053-24
  • IEC 61557-12
  • IEC 61326-1
  • IEEE 1588
  • IEC 62586
Memory Capacity 512 MB
Number Of Outputs 1 pulse
Product Certifications
  • CE
  • cULus
  • N998
Type Of Measurement
  • current
  • voltage
  • frequency
  • active and reactive power total
  • apparent power total
  • power factor total
  • active and reactive power per phase, rms
  • apparent power per phase, rms
  • power factor per phase, rms
  • active and reactive energy
  • apparent energy
Communication Port Protocol
  • Modbus RTU 115 kbauds - 2-wire
  • ION 115 kbauds - 2-wire
  • DNP3
  • IEC 61850
  • Modbus TCP/IP
  • Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
  • RSTP 801.1d 2004
  • Ansi C12.19
  • DLMS
Frequency Measurement Range 42-69 Hz
Communication Service
  • DHCP
  • RSTP support
  • NTP time synchronization
  • SMTP e-mail notification
  • PTP time synchronization
Power Consumption In Va 18 VA 415 V AC
Display Resolution 320 x 240 pixels QVGA
Number Of Inputs
  • 3 digital 30 V AC
  • 3 digital 60 V DC
Net Weight 706 g
Type Of Installation indoor installation
Depth 78.5 mm
Measurement Current 50-10000 mA
Information Displayed
  • voltage
  • current
  • frequency
  • power
  • energy consumption
  • harmonic distortion
[Us] Rated Supply Voltage
  • 90...415 V AC 45...65 Hz +/- 10 %
  • 110...415 V DC +/- 10 %
Mounting Mode flush-mounted
Measurement Accuracy
  • current +/- 0.1 %
  • voltage +/- 0.1 %
  • active energy +/- 0.2 %
Mounting Support framework
Poles Description
  • 1P + N
  • 3P
  • 3P + N
Data Recording
  • alarm logs
  • waveform logs
  • sequence of event recording
  • event logs
  • sag and swell logs
  • data logs
  • harmonics logs
  • GPS synchronisation
  • time stamping
  • trending/forecasting
  • min/max of instantaneous values
Line Rated Current
  • 10 A
  • 5 A
  • 1 A
Cybersecurity
  • Syslog protocol support
  • robust security logs
  • enable/disable communication ports
  • password protection
  • port hardening
Isolation Voltage
  • III400-690 V conforming to IEC 61010-1:ed. 3
  • III400-690 V conforming to EN 61010-1:ed. 3
  • III347-600 V conforming to UL 61010-1:ed. 3
  • III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Analogue Input Type
  • voltage 5 MOhm)
  • current 0.3 mOhm)
Web Services
  • customizable home page
  • file upload/download via FTP
  • file upload/download via SFTP
  • web server
  • alarm notification by e-mail
  • viewing of captured waveform (FTP)
  • viewing of captured waveform (web)
  • HTTPS server
Width 98 mm
Display Type colour TFT LCD
Device Application
  • revenue billing
  • WAGES metering
  • data aggregation
  • power monitoring
Accuracy Class
  • class 0.2S active energy IEC 62053-22
  • class 0.2 active energy ANSI C12.20
  • class 0.2 active power IEC 61557-12
  • class 0.5S reactive energy IEC 62053-24
  • class 0.5 power factor IEC 61557-12
  • class 0.2 voltage IEC 61557-12
  • class 0.2 current IEC 61557-12
  • class 0.2 frequency IEC 61557-12
  • class 0.2 active energy IEC 61557-12
Installation Category III
Environmental Disclosure ENVPEP1512006EN
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1512006EN
Eu Rohs Directive Compliant
Ambient Air Temperature For Operation -25-70 °C
Electromagnetic Compatibility
  • electrostatic discharge IEC 61000-4-2
  • radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3
  • electrical fast transient/burst immunity test IEC 61000-4-4
  • surge immunity test IEC 61000-4-5
  • conducted RF disturbances IEC 61000-4-6
  • magnetic field at power frequency IEC 61000-4-8
  • voltage dips and interruptions immunity test IEC 61000-4-11
  • immunity to impulse waves IEC 61000-4-12
  • conducted and radiated emissions EN 55022
  • conducted and radiated emissions EN 55011
  • conducted and radiated emissions FCC part 15
  • conducted and radiated emissions ICES-003
  • conducted RF disturbances 2...150 Hz) CLC/TR 50579
  • surge withstand IEEE C37.90.1
Ambient Air Temperature For Storage -40-85 °C
Relative Humidity 5-95 %
Ip Degree Of Protection
  • front IP54 IEC 60529
  • body IP30 IEC 60529
Operating Altitude 9842.52 ft (3000 m)