Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LGA36000S40X – Automatic switch, PowerPact L, 400A, 3 pole, 600VAC, 18kA, I-Line, magnetic
LGA36000S40X
Automatic switch, PowerPact L, 400A, 3 pole, 600VAC, 18kA, I-Line, magnetic

PowerPacT L-Frame automatic switches are a disconnect device and can be used to open and close a circuit under normal operating conditions. The automatic switches are similar in construction to, use the same accessories, and offer the same connection possibilities as the L-Frame circuit breaker version. The switches have a factory set, nonadjustable trip point calibrated to protect the molded case switch. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT L, 400A, 3 pole, automatic switch has a withstand current rating of 18kA at 600VAC. PowerPacT L automatic switches comply to UL, CSA, and IEC standards.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Range Of Product PowerPact L
Product Or Component Type automatic switch
Trip Unit Technology magnetic
Warranty 18 months
Terminal Identifier AL600LF52K3
Height 13.38 in
Mounting Mode I-Line
Short-Circuit Withstand
  • 65 kA 240 V UL 489
  • 35 kA 480 V UL 489
  • 18 kA 600 V UL 489
Tightening Torque 50-50 N.m 95-240 mm² (AWG 3/0...500 kcmil)
Breaking Capacity Code G
Magnetic Tripping Current 4800-4800 A
Poles Description 3P
Line Rated Current 400 A
Width 5.51 in
Electrical Connection
  • lugs load
  • I-Line connection line
Depth 6.61 in
[Ue] Rated Operational Voltage 600 V AC
Awg Gauge 2 x AWG 3/0...500 kcmil ( aluminium/copper )
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile ENVEOLI2206029EN
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP2206029EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Eu Rohs Directive Compliant
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Product Certifications
  • UL Listed
  • CE
  • IEC
  • CSA
  • CCC
  • NMX
Documents
Royal Wholesale Electric

5.0

Powered by