Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC3D115P7A64 – Star delta starter, TeSys Deca, 3 x 3P (3NO), 115A, 230V AC coil
LC3D115P7A64
Star delta starter, TeSys Deca, 3 x 3P (3NO), 115A, 230V AC coil
Specifications
Product Certifications
  • CSA
  • BV
  • GL
  • CCC
  • GOST
  • UL
  • DNV
  • LROS (Lloyds register of shipping)
  • RINA
Interlocking Type mechanical
[Uc] Control Circuit Voltage 230 V AC 50/60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Standards
  • IEC 60947-5-1
  • CSA C22.2 No 14
  • EN 60947-5-1
  • UL 508
  • EN 60947-4-1
  • IEC 60947-4-1
Pole Contact Composition 3 x 3 NO
Mounting Support plate
Control Circuit Type AC 50/60 Hz
Contactor Application motor control
Product Or Component Type star delta starter
Product Name TeSys Deca
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Range TeSys
Device Presentation pre-wired
Utilisation Category AC-3
[Ie] Rated Operational Current 115 A 60 °C) <= 440 V AC AC-3 power circuit
Auxiliary Contact Composition
  • 1 NC KM2 line contactor
  • 1 NO KM3 delta contactor
Electrical Durability 0.95 Mcycles 115 A AC-3 <= 440 V
Overvoltage Category III
Motor Power Kw
  • 110 kW 380/400 V AC 50/60 Hz
  • 110 kW 415 V AC 50/60 Hz
  • 110 kW 440 V AC 50/60 Hz
  • 63 kW 220/230 V AC 50/60 Hz
[Ui] Rated Insulation Voltage
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • signalling circuit 600 V CSA
  • signalling circuit 600 V UL
  • power circuit 1000 V IEC 60947-4-1
  • signalling circuit 1000 V IEC 60947-1
Device Short Name LC3D
Poles Description 3 x 3P
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA signalling circuit
Height 555 mm
Control Circuit Voltage Limits
  • drop-out 0.3...0.5 Uc 50/60 Hz 55 °C)
  • operational 0.8...1.15 Uc 50/60 Hz 55 °C)
Starting Time 30 s
Net Weight 12.1 kg
Inrush Power In Va
  • 280-350 VA 60 Hz 0.8 20 °C)
  • 280-350 VA 50 Hz 0.8 20 °C)
Connections - Terminals
  • power circuit connector 1 10-120 mm² flexible without cable end
  • power circuit connector 2 10-50 mm² flexible without cable end
  • power circuit connector 1 10-120 mm² flexible with cable end
  • power circuit connector 2 10-50 mm² flexible with cable end
  • power circuit connector 1 10-120 mm² solid without cable end
  • power circuit connector 2 10-50 mm² solid without cable end
  • control circuit connector 1 1-2.5 mm² flexible without cable end
  • control circuit connector 2 1-2.5 mm² flexible without cable end
  • control circuit connector 1 1-2.5 mm² flexible with cable end
  • control circuit connector 2 1-2.5 mm² flexible with cable end
  • control circuit connector 1 1-2.5 mm² solid without cable end
  • control circuit connector 2 1-2.5 mm² solid without cable end
Coil Technology without built-in suppressor module
Maximum Operating Rate 30 cyc/h 60 °C
Signalling Circuit Frequency 25...400 Hz
Tightening Torque
  • power circuit 12 N.m connector flat Ø 6...8 mm
  • control circuit 1.2 N.m connector flat Ø 6 mm
  • control circuit 1.2 N.m connector Philips No 2
Mechanical Durability 8 Mcycles
Auxiliary Contacts Type
  • mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC
  • mirror contact IEC 60947-4-1 3 x 1 NC
Hold-In Power Consumption In Va
  • 2-18 VA 60 Hz 0.3 20 °C)
  • 2-18 VA 50 Hz 0.3 20 °C)
Switching Voltage 17 V signalling circuit
Width 450 mm
Depth 205 mm
Heat Dissipation 3-8 W 50/60 Hz
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1503009EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile ENVEOLI1503009EN
Eu Rohs Directive Compliant
Mechanical Robustness
  • vibrations contactor open2 Gn, 5...300 Hz
  • vibrations contactor closed4 Gn, 5...300 Hz
  • shocks contactor closed15 Gn for 11 ms
  • shocks contactor open6 Gn for 11 ms
Ambient Air Temperature For Operation
  • -40-60 °C
  • 60-70 °C with derating
Pollution Degree 3
Insulation Resistance > 10 MOhm signalling circuit
Flame Retardance V1 conforming to UL 94
Ambient Air Temperature For Storage -60-80 °C
Protective Treatment TH IEC 60068-2-30
Ip Degree Of Protection IP20 front face IEC 60529
Operating Altitude 9842.52 ft (3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews