Changeover contactor, TeSys Deca, 4P(4NO), AC-1, <=440V, 20A, 24V DC coil, screw clamp terminals
Specifications
Product Certifications
  • UL
  • GL
  • GOST
  • CCC
  • BV
  • DNV
  • CSA
  • RINA
  • LROS (Lloyds register of shipping)
Interlocking Type mechanical
[Uc] Control Circuit Voltage 24 V DC
[Ue] Rated Operational Voltage
  • power circuit <= 690 V AC 25...400 Hz
  • power circuit <= 300 V DC
Power Dissipation Per Pole 1.56 W AC-1
Average Impedance 2.5 mOhm - Ith 20 A 50 Hz power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C signalling circuit
  • 20 A 60 °C power circuit
Mounting Support
  • plate
  • rail
Control Circuit Type DC standard
Standards
  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application resistive load
Rated Breaking Capacity 250 A 440 V power circuit IEC 60947
Product Or Component Type changeover contactor
Irms Rated Making Capacity
  • 250 A 440 V power circuit IEC 60947
  • 140 A AC signalling circuit IEC 60947-5-1
  • 250 A DC signalling circuit IEC 60947-5-1
Product Name TeSys D
Associated Fuse Rating
  • 25 A gG <= 690 V type 1 power circuit
  • 20 A gG <= 690 V type 2 power circuit
  • 10 A gG signalling circuit IEC 60947-5-1
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Connections - Terminals
  • power circuit screw clamp terminals 1 1-4 mm²flexible without cable end
  • power circuit screw clamp terminals 2 1-4 mm²flexible without cable end
  • power circuit screw clamp terminals 1 1-4 mm²flexible with cable end
  • power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end
  • power circuit screw clamp terminals 1 1-4 mm²solid
  • power circuit screw clamp terminals 2 1-4 mm²solid
  • control circuit screw clamp terminals 1 1-4 mm²flexible without cable end
  • control circuit screw clamp terminals 2 1-4 mm²flexible without cable end
  • control circuit screw clamp terminals 1 1-4 mm²flexible with cable end
  • control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end
  • control circuit screw clamp terminals 1 1-4 mm²solid
  • control circuit screw clamp terminals 2 1-4 mm²solid
Range TeSys
Pole Contact Composition 4 NO
Device Presentation preassembled, with prewired power connections
Utilisation Category
  • AC-1
  • AC-3
  • AC-3e
  • AC-4
[Ie] Rated Operational Current 20 A 60 °C) <= 440 V AC AC-1 power circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque
  • power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • power circuit 1.7 N.m screw clamp terminals Philips No 2
  • control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • control circuit 1.7 N.m screw clamp terminals Philips No 2
Mechanical Durability 30 Mcycles
Poles Description 4P
Operating Time
  • 53.55...72.45 ms closing
  • 16...24 ms opening
Overvoltage Category III
[Ui] Rated Insulation Voltage
  • power circuit 690 V IEC 60947-4-1
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • signalling circuit 690 V IEC 60947-1
  • signalling circuit 600 V CSA
  • signalling circuit 600 V UL
Device Short Name LC2D
[Icw] Rated Short-Time Withstand Current
  • 30 A 40 °C - 10 min power circuit
  • 61 A 40 °C - 1 min power circuit
  • 105 A 40 °C - 10 s power circuit
  • 210 A 40 °C - 1 s power circuit
  • 100 A - 1 s signalling circuit
  • 120 A - 500 ms signalling circuit
  • 140 A - 100 ms signalling circuit
Protective Cover with
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA signalling circuit
Control Circuit Voltage Limits
  • 0.1...0.25 Uc -40-70 °C drop-out DC
  • 0.7...1.25 Uc -40-60 °C operational DC
  • 1...1.25 Uc 60-70 °C operational DC
Hold-In Power Consumption In W 5.4-5.4 W 20 °C
Insulation Resistance > 10 MOhm signalling circuit
Coil Technology built-in bidirectional peak limiting diode suppressor
Time Constant 28 ms
Minimum Switching Voltage 17 V signalling circuit
Signalling Circuit Frequency 25...400 Hz
Inrush Power In W 5.4-5.4 W 20 °C)
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP110230EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile ENVEOLI1102030EN
Eu Rohs Directive Compliant
Mechanical Robustness
  • vibrations contactor open2 Gn, 5...300 Hz
  • vibrations contactor closed4 Gn, 5...300 Hz
  • shocks contactor open10 Gn for 11 ms
  • shocks contactor closed15 Gn for 11 ms
Ambient Air Temperature For Operation
  • -40-60 °C
  • 60-70 °C with derating
Height 85 mm
Climatic Withstand
  • IACS E10
  • IEC 60947-1 Annex Q category D
Pollution Degree 3
Net Weight 0.73 kg
Flame Retardance V1 conforming to UL 94
Ambient Air Temperature For Storage -60-80 °C
Protective Treatment TH IEC 60068-2-30
Ip Degree Of Protection IP20 front face IEC 60529
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 90 mm
Depth 90 mm