Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC2D80AEHE – TeSys Deca reversing contactor 3P 66A AC-3/AC-3e up to 440V coil 48-130V AC/DC
LC2D80AEHE
TeSys Deca reversing contactor 3P 66A AC-3/AC-3e up to 440V coil 48-130V AC/DC

TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Interlocking Type mechanical
[Uc] Control Circuit Voltage
  • 48...130 V AC 50/60 Hz
  • 48...130 V DC
[Ue] Rated Operational Voltage power circuit 690 V AC 25...400 Hz
Power Dissipation Per Pole
  • 9.6 W AC-1
  • 6.5 W AC-3
  • 6.5 W AC-3e
Average Impedance 1.5 mOhm - Ith 80 A 50 Hz power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C signalling circuit
  • 80 A 60 °C power circuit
Mounting Support
  • plate
  • rail
Control Circuit Type
  • AC 50/60 Hz AC/DC electronic
  • DC AC/DC electronic
Standards
  • EN/IEC 60947-4-1
  • EN/IEC 60947-5-1
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1
  • IEC 60335-1
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
  • motor control
  • resistive load
Rated Breaking Capacity 1000 A 440 V power circuit IEC 60947
Product Or Component Type reversing contactor
Product Certifications
  • CCC
  • CSA
  • EAC
  • UL
  • KC
  • DNV-GL
  • LROS (Lloyds register of shipping)
  • UKCA
Irms Rated Making Capacity
  • 140 A AC signalling circuit IEC 60947-5-1
  • 250 A DC signalling circuit IEC 60947-5-1
  • 1000 A 440 V power circuit IEC 60947
Product Name
  • Tesys Deca green
  • TeSys Deca
Associated Fuse Rating
  • 10 A gG signalling circuit IEC 60947-5-1
  • 125 A gG <= 690 V type 1 power circuit
  • 125 A gG <= 690 V type 2 power circuit
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Connections - Terminals
  • control circuit screw clamp terminals 1 1-4 mm²flexible with cable end
  • control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end
  • power circuit EverLink BTR screw connectors 1 1-35 mm²flexible with cable end
  • power circuit EverLink BTR screw connectors 2 1-25 mm²flexible with cable end
  • control circuit screw clamp terminals 1 1-4 mm²solid
  • control circuit screw clamp terminals 2 1-4 mm²solid
  • power circuit EverLink BTR screw connectors 1 1-35 mm²solid
  • power circuit EverLink BTR screw connectors 2 1-25 mm²solid
  • control circuit screw clamp terminals 1 1-4 mm²flexible
  • control circuit screw clamp terminals 2 1-4 mm²flexible
  • power circuit EverLink BTR screw connectors 1 1-35 mm²flexible
  • power circuit EverLink BTR screw connectors 2 1-25 mm²flexible
Range
  • TeSys
  • TeSys Deca
Pole Contact Composition 3 NO
Device Presentation preassembled with reversing power busbar
Utilisation Category
  • AC-1
  • AC-3
  • AC-3e
Operating Time
  • 55...65 ms closing
  • 20...80 ms opening
[Ie] Rated Operational Current
  • 80 A 60 °C) <= 440 V AC-1 power circuit
  • 66 A 60 °C) <= 440 V AC-3 power circuit
  • 66 A 60 °C) AC-3e power circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Electrical Durability
  • 1 Mcycles 66 A AC-3 <= 440 V
  • 0.5 Mcycles 80 A AC-1 <= 440 V
  • 1 Mcycles 66 A AC-3e
Tightening Torque
  • control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • control circuit 1.7 N.m screw clamp terminals Philips No 2
  • power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm
  • power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm
Poles Description 3P
Overvoltage Category III
Motor Power Kw
  • 18.5 kW 220...230 V AC 50 Hz
  • 37 kW 380...400 V AC 50 Hz
  • 37 kW 415 V AC 50 Hz
  • 37 kW 440 V AC 50 Hz
  • 37 kW 500 V AC 50 Hz
  • 37 kW 660...690 V AC 50 Hz
Maximum Horse Power Rating
  • 5 hp 115 V at AC 60 Hz for 1 phase
  • 10 hp 230/240 V at AC 60 Hz for 1 phase
  • 20 hp 200/208 V at AC 60 Hz for 3 phase
  • 20 hp 230/240 V at AC 60 Hz for 3 phase
  • 40 hp 460/480 V at AC 60 Hz for 3 phase
  • 50 hp 575/600 V at AC 60 Hz for 3 phase
[Ui] Rated Insulation Voltage
  • power circuit 690 V IEC 60947-4-1
  • signalling circuit 690 V IEC 60947-1
Mechanical Durability 6 Mcycles
Device Short Name LC2D
[Icw] Rated Short-Time Withstand Current
  • 100 A - 1 s signalling circuit
  • 120 A - 500 ms signalling circuit
  • 140 A - 100 ms signalling circuit
  • 520 A 40 °C - 10 s power circuit
  • 900 A 40 °C - 1 s power circuit
  • 110 A 40 °C - 10 min power circuit
  • 260 A 40 °C - 1 min power circuit
Protective Cover with
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA signalling circuit
Control Circuit Voltage Limits
  • <= 0.1 Uc -40-70 °C drop-out AC/DC
  • 0.85...1.1 Uc -40-60 °C operational AC/DC
  • 1...1.1 Uc 60-70 °C operational AC/DC
Hold-In Power Consumption In W 0.9-0.9 W 20 °C
Insulation Resistance > 10 MOhm signalling circuit
Inrush Power In Va 23-23 VA 50/60 Hz 20 °C)
Coil Technology built-in bidirectional peak limiting
Minimum Switching Voltage 17 V signalling circuit
Signalling Circuit Frequency 25...400 Hz
Heat Dissipation 0.9-0.9 W 50/60 Hz
Inrush Power In W 19-19 W 20 °C
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va 1.4-1.4 VA 20 °C) 50/60 Hz
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1607010EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile ENVEOLI1607010EN
Eu Rohs Directive Compliant
Halogen Content Performance Halogen free plastic parts & cables product
Mechanical Robustness
  • vibrations contactor open2 Gn, 5...300 Hz
  • vibrations contactor closed4 Gn, 5...300 Hz
  • shocks contactor open10 Gn for 11 ms
  • shocks contactor closed15 Gn for 11 ms
Ambient Air Temperature For Operation
  • -40-60 °C
  • 60-70 °C with derating
Height 122 mm
Climatic Withstand
  • IACS E10
  • IEC 60947-1 Annex Q category D
Pollution Degree 3
Net Weight 2.174 kg
Flame Retardance V1 conforming to UL 94
Ambient Air Temperature For Storage -60-80 °C
Protective Treatment TH IEC 60068-2-30
Ip Degree Of Protection IP20 front face IEC 60529
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Color
  • Gray SE GREY 6)
  • Green SE GREEN 2)
Width 119 mm
Depth 120 mm
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews