Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC2D256L7 – Reversing contactor, TeSys Deca, 3P(3NO), AC-3,
LC2D256L7
Reversing contactor, TeSys Deca, 3P(3NO), AC-3, <=440V 25A, 200V AC 50/60Hz coil, lugs-ring terminals
Specifications
Product Certifications
  • RINA
  • LROS (Lloyds register of shipping)
  • GL
  • UL
  • CCC
  • CSA
  • BV
  • DNV
  • GOST
Interlocking Type mechanical
[Uc] Control Circuit Voltage 200 V AC 50/60 Hz
[Ue] Rated Operational Voltage
  • power circuit <= 690 V AC 25...400 Hz
  • power circuit <= 300 V DC
Power Dissipation Per Pole
  • 1.25 W AC-3
  • 3.2 W AC-1
Average Impedance 2 mOhm - Ith 40 A 50 Hz power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C signalling circuit
  • 40 A 60 °C power circuit
Mounting Support
  • rail
  • plate
Control Circuit Type AC 50/60 Hz
Standards
  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
  • motor control
  • resistive load
Rated Breaking Capacity 450 A 440 V power circuit IEC 60947
Product Or Component Type reversing contactor
Irms Rated Making Capacity
  • 140 A AC signalling circuit IEC 60947-5-1
  • 250 A DC signalling circuit IEC 60947-5-1
  • 450 A 440 V power circuit IEC 60947
Product Name TeSys Deca
Associated Fuse Rating
  • 10 A gG signalling circuit IEC 60947-5-1
  • 63 A gG <= 690 V type 1 power circuit
  • 40 A gG <= 690 V type 2 power circuit
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Connections - Terminals
  • control circuit lugs-ring terminals 8 mm)
  • power circuit lugs-ring terminals 10 mm)
Range TeSys
Pole Contact Composition 3 NO
Device Presentation preassembled with reversing power busbar
Utilisation Category
  • AC-3
  • AC-1
[Ie] Rated Operational Current
  • 25 A 60 °C) <= 440 V AC AC-3 power circuit
  • 40 A 60 °C) <= 440 V AC AC-1 power circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque
  • control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5
  • control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5
  • power circuit 2.5 N.m lugs-ring terminals flat Ø 8 mm M4
  • power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4
Electrical Durability
  • 1.65 Mcycles 25 A AC-3 <= 440 V
  • 1.4 Mcycles 40 A AC-1 <= 440 V
Mechanical Durability 15 Mcycles
Poles Description 3P
Operating Time
  • 12...22 ms closing
  • 4...19 ms opening
Overvoltage Category III
Motor Power Kw
  • 5.5 kW 220...230 V AC 50 Hz
  • 11 kW 380...400 V AC 50 Hz
  • 11 kW 415...440 V AC 50 Hz
  • 15 kW 500 V AC 50 Hz
  • 15 kW 660...690 V AC 50 Hz
Maximum Horse Power Rating
  • 3 hp 230/240 V at AC 60 Hz for 1 phase
  • 5 hp 200/208 V at AC 60 Hz for 3 phase
  • 2 hp 115 V at AC 60 Hz for 1 phase
  • 7.5 hp 230/240 V at AC 60 Hz for 3 phase
  • 15 hp 460/480 V at AC 60 Hz for 3 phase
  • 20 hp 575/600 V at AC 60 Hz for 3 phase
[Ui] Rated Insulation Voltage
  • power circuit 690 V IEC 60947-4-1
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • signalling circuit 690 V IEC 60947-1
  • signalling circuit 600 V CSA
  • signalling circuit 600 V UL
Device Short Name LC2D
[Icw] Rated Short-Time Withstand Current
  • 50 A 40 °C - 10 min power circuit
  • 120 A 40 °C - 1 min power circuit
  • 240 A 40 °C - 10 s power circuit
  • 380 A 40 °C - 1 s power circuit
  • 100 A - 1 s signalling circuit
  • 120 A - 500 ms signalling circuit
  • 140 A - 100 ms signalling circuit
Protective Cover with
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA signalling circuit
Control Circuit Voltage Limits
  • 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz
  • 0.8...1.1 Uc -40-60 °C operational AC 50 Hz
  • 0.85...1.1 Uc -40-60 °C operational AC 60 Hz
  • 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
Insulation Resistance > 10 MOhm signalling circuit
Inrush Power In Va
  • 70-70 VA 60 Hz 0.75 20 °C)
  • 70-70 VA 50 Hz 0.75 20 °C)
Coil Technology without built-in suppressor module
Minimum Switching Voltage 17 V signalling circuit
Signalling Circuit Frequency 25...400 Hz
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va
  • 7.5-7.5 VA 60 Hz 0.3 20 °C)
  • 7-7 VA 50 Hz 0.3 20 °C)
Heat Dissipation 2-3 W 50/60 Hz
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1501004
Sustainable Offer Status Green Premium product
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: Cancer - www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile ENVEOLI1501004
Eu Rohs Directive Compliant
Mechanical Robustness
  • vibrations contactor open2 Gn, 5...300 Hz
  • vibrations contactor closed4 Gn, 5...300 Hz
  • shocks contactor closed15 Gn for 11 ms
  • shocks contactor open8 Gn for 11 ms
Ambient Air Temperature For Operation
  • -40-60 °C
  • 60-70 °C with derating
Height 85 mm
Climatic Withstand
  • IACS E10
  • IEC 60947-1 Annex Q category D
Pollution Degree 3
Net Weight 0.787 kg
Flame Retardance V1 conforming to UL 94
Ambient Air Temperature For Storage -60-80 °C
Protective Treatment TH IEC 60068-2-30
Ip Degree Of Protection IP20 front face IEC 60529
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 90 mm
Depth 92 mm
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews