TeSys K contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. They can be used to create motor starters for almost any type of application. TeSys K contactors offer quick simple setup, while maintaining a compact size. Contactors have both Horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors are UL Listed and CSA certified. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Contactor Application
  • motor control
  • resistive load
Product Or Component Type contactor
Range TeSys
Device Application control
Device Short Name LC1K
Warranty 18 months
Minimum Switching Current 5 mA signalling circuit
Mechanical Robustness
  • shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27
  • shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27
  • shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27
  • shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27
  • shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27
  • shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27
  • vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6
  • vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
[Uc] Control Circuit Voltage 120 V AC 50/60 Hz
[Ue] Rated Operational Voltage
  • power circuit <= 690 V AC <= 400 Hz
  • signalling circuit <= 690 V AC <= 400 Hz
Height 58 mm
Average Impedance 3 mOhm - Ith 20 A 50 Hz power circuit
Auxiliary Contact Composition 1 NO
Control Circuit Voltage Limits
  • operational 0.8...1.15 Uc 50 °C)
  • drop-out >= 0.20 Uc 50 °C)
Non Overlap Distance 0.5 mm
[Ith] Conventional Free Air Thermal Current
  • 20 A 60 °C power circuit
  • 10 A 50 °C signalling circuit
Control Circuit Type AC 50/60 Hz
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm signalling circuit
Rated Breaking Capacity
  • 110 A 220...230 V IEC 60947
  • 110 A 380...400 V IEC 60947
  • 110 A 415 V IEC 60947
  • 110 A 440 V IEC 60947
  • 80 A 500 V IEC 60947
  • 70 A 660...690 V IEC 60947
Irms Rated Making Capacity
  • 110 A AC power circuit IEC 60947
  • 110 A AC signalling circuit IEC 60947
Motor Power Kw
  • 2.2 kW 220...230 V AC 50/60 Hz AC-3
  • 4 kW 380...415 V AC 50/60 Hz AC-3
  • 4 kW 440/690 V AC 50/60 Hz AC-3
  • 2.2 kW 220...230 V AC 50/60 Hz AC-3e
  • 4 kW 380...415 V AC 50/60 Hz AC-3e
  • 4 kW 440/690 V AC 50/60 Hz AC-3e
  • 2.2 kW 220...230 V AC 50/60 Hz AC-4
  • 4 kW 380...415 V AC 50/60 Hz AC-4
  • 4 kW 440/690 V AC 50/60 Hz AC-4
Associated Fuse Rating
  • 25 A gG <= 440 V power circuit
  • 25 A aM power circuit
  • 10 A gG signalling circuit IEC 60947
  • 10 A gG signalling circuit VDE 0660
[Uimp] Rated Impulse Withstand Voltage 8 kV
Inrush Power In Va 30-30 VA 20 °C)
Connections - Terminals
  • screw clamp terminals 1 1.5-4 mm²solid
  • screw clamp terminals 1 0.75-4 mm²flexible without cable end
  • screw clamp terminals 1 0.34-2.5 mm²flexible with cable end
  • screw clamp terminals 2 1.5-4 mm²solid
  • screw clamp terminals 2 0.75-4 mm²flexible without cable end
  • screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Pole Contact Composition 3 NO
Utilisation Category
  • AC-3
  • AC-3e
  • AC-1
  • AC-4
[Ie] Rated Operational Current
  • 9 A 60 °C) <= 440 V AC AC-3 power circuit
  • 9 A 60 °C) <= 440 V AC AC-3e power circuit
  • 20 A 60 °C) <= 690 V AC AC-1 power circuit
Minimum Switching Voltage 17 V signalling circuit
Maximum Operating Rate 3600 cyc/h
Signalling Circuit Frequency <= 400 Hz
Electrical Durability
  • 1.3 Mcycles 9 A AC-3 <= 440 V
  • 1.3 Mcycles 9 A AC-3e <= 440 V
  • 0.16 Mcycles 20 A AC-1 <= 690 V
  • 0.02 Mcycles 54 A AC-4 <= 440 V
Mechanical Durability 10 Mcycles
Auxiliary Contacts Type instantaneous 1 NO
Poles Description 3P
Hold-In Power Consumption In Va 4.5-4.5 VA 20 °C)
Operating Time
  • 10...20 ms coil de-energisation and NO opening
  • 10...20 ms coil energisation and NO closing
Width 45 mm
Overvoltage Category III
Depth 57 mm
[Icw] Rated Short-Time Withstand Current
  • 90 A 50 °C - 1 s power circuit
  • 85 A 50 °C - 5 s power circuit
  • 80 A 50 °C - 10 s power circuit
  • 60 A 50 °C - 30 s power circuit
  • 45 A 50 °C - 1 min power circuit
  • 40 A 50 °C - 3 min power circuit
  • 20 A 50 °C - >= 15 min power circuit
  • 80 A - 1 s signalling circuit
  • 90 A - 500 ms signalling circuit
  • 110 A - 100 ms signalling circuit
Heat Dissipation 1.3-1.3 W
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1503003EN
Sustainable Offer Status Green Premium product
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile ENVEOLI1503003EN
Eu Rohs Directive Compliant
Product Certifications
  • CB Scheme
  • CCC
  • UL
  • CSA
  • EAC
  • CE
  • UKCA
Standards
  • EN/IEC 60947-4-1
  • GB/T 14048.4
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1
  • JIS C8201-4-1
Flame Retardance
  • V1 conforming to UL 94
  • requirement 2 conforming to NF F 16-101
  • requirement 2 conforming to NF F 16-102
Protective Treatment
  • TC IEC 60068
  • TC DIN 50016
Operating Altitude 6561.68 ft (2000 m) without derating