Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC1D95U7 – IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 240VAC 50/60Hz coil, open style
LC1D95U7
IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 240VAC 50/60Hz coil, open style

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
[Uc] Control Circuit Voltage 240 V AC 50/60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application
  • motor control
  • resistive load
Product Or Component Type contactor
Range TeSys
Utilisation Category
  • AC-3
  • AC-3e
  • AC-4
  • AC-1
[Ie] Rated Operational Current
  • 95 A 60 °C) <= 440 V AC-3 power circuit
  • 125 A 60 °C) <= 690 V AC-1 power circuit
  • 95 A 60 °C) <= 440 V AC-3e power circuit
Poles Description 3P
Device Short Name LC1D
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA signalling circuit
Power Dissipation Per Pole
  • 12.5 W AC-1
  • 7.2 W AC-3
  • 7.2 W AC-3e
Average Impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C signalling circuit
  • 125 A 60 °C power circuit
Control Circuit Voltage Limits
  • 0.8...1.1 Uc -40-55 °C operational AC 50 Hz
  • 0.85...1.1 Uc -40-55 °C operational AC 60 Hz
  • 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz
  • 1...1.1 Uc 55-70 °C operational AC 50/60 Hz
Mounting Support
  • rail
  • plate
Contact Compatibility M11
Control Circuit Type AC 50/60 Hz
Safety Reliability Level
  • B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Pollution Degree 3
Insulation Resistance > 10 MOhm signalling circuit
Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
Irms Rated Making Capacity
  • 1100 A 440 V AC power circuit IEC 60947
  • 140 A AC signalling circuit IEC 60947-5-1
  • 250 A DC signalling circuit IEC 60947-5-1
Associated Fuse Rating
  • 10 A gG signalling circuit IEC 60947-5-1
  • 200 A gG <= 690 V type 1 power circuit
  • 160 A gG <= 690 V type 2 power circuit
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Inrush Power In Va
  • 245-245 VA 60 Hz 0.75 20 °C)
  • 245-245 VA 50 Hz 0.75 20 °C)
Pole Contact Composition 3 NO
Connections - Terminals
  • control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end
  • control circuit screw clamp terminals 1 1-2.5 mm² flexible with cable end
  • control circuit screw clamp terminals 1 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 2 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 1 1-4 mm² solid without cable end
  • control circuit screw clamp terminals 2 1-4 mm² solid without cable end
  • power circuit connector 1 4-50 mm² flexible without cable end
  • power circuit connector 2 4-25 mm² flexible without cable end
  • power circuit connector 1 4-50 mm² flexible with cable end
  • power circuit connector 2 4-16 mm² flexible with cable end
  • power circuit connector 1 4-50 mm² solid without cable end
  • power circuit connector 2 4-25 mm² solid without cable end
Coil Technology without built-in suppressor module
Operating Time
  • 20...35 ms closing
  • 6...20 ms opening
Minimum Switching Voltage 17 V signalling circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Signalling Circuit Frequency 25...400 Hz
Tightening Torque
  • control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm
  • control circuit 1.2 N.m screw clamp terminals Philips No 2
  • power circuit 12 N.m connector flat Ø 6 to Ø 8 mm
  • power circuit 12 N.m connector hexagonal 4 mm
  • control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Electrical Durability
  • 1.2 Mcycles 95 A AC-3
  • 1.3 Mcycles 125 A AC-1
  • 1.2 Mcycles 95 A AC-3e
Mechanical Durability 4 Mcycles
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Compatibility Code LC1D
Hold-In Power Consumption In Va
  • 26-26 VA 60 Hz 0.3 20 °C)
  • 26-26 VA 50 Hz 0.3 20 °C)
Overvoltage Category III
Maximum Horse Power Rating
  • 7.5 hp 120 V at AC 60 Hz for 1 phase
  • 15 hp 230/240 V at AC 60 Hz for 1 phase
  • 30 hp 200/208 V at AC 60 Hz for 3 phase
  • 30 hp 230/240 V at AC 60 Hz for 3 phase
  • 60 hp 460/480 V at AC 60 Hz for 3 phase
  • 60 hp 575/600 V at AC 60 Hz for 3 phase
Motor Power Kw
  • 25 kW 220...230 V AC 50 Hz AC-3)
  • 45 kW 380...400 V AC 50 Hz AC-3)
  • 45 kW 415...440 V AC 50 Hz AC-3)
  • 55 kW 500 V AC 50 Hz AC-3)
  • 45 kW 660...690 V AC 50 Hz AC-3)
  • 15 kW 400 V AC 50 Hz AC-4)
  • 25 kW 220...230 V AC 50 Hz AC-3e)
  • 45 kW 380...400 V AC 50 Hz AC-3e)
  • 45 kW 415...440 V AC 50 Hz AC-3e)
  • 55 kW 500 V AC 50 Hz AC-3e)
  • 45 kW 660...690 V AC 50 Hz AC-3e)
[Ui] Rated Insulation Voltage
  • power circuit 1000 V IEC 60947-4-1
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • signalling circuit 690 V IEC 60947-1
  • signalling circuit 600 V CSA
  • signalling circuit 600 V UL
[Icw] Rated Short-Time Withstand Current
  • 1100 A 40 °C - 1 s power circuit
  • 800 A 40 °C - 10 s power circuit
  • 400 A 40 °C - 1 min power circuit
  • 135 A 40 °C - 10 min power circuit
  • 140 A - 100 ms signalling circuit
  • 120 A - 500 ms signalling circuit
  • 100 A - 1 s signalling circuit
Heat Dissipation 6-10 W 50/60 Hz
Protective Cover with
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP110205EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive Compliant
Product Certifications
  • IECEE CB Scheme
  • UL
  • CSA
  • CCC
  • EAC
  • LROS (Lloyds register of shipping)
  • RINA
  • BV
  • DNV-GL
Height 127 mm
Standards
  • EN/IEC 60947-1
  • EN/IEC 60947-4-1
  • EN/IEC 60947-5-1
  • UL 60947-4-1
  • UL 60947-5-1
  • CSA C22.2 No 60947-4-1
  • CSA C22.2 No 60947-5-1
  • GB/T 14048.4
Climatic Withstand IACS E10 exposure to damp heat
Net Weight 1.61 kg
Flame Retardance V1 conforming to UL 94
Protective Treatment THIEC 60068-2-30
Ip Degree Of Protection IP20 front face IEC 60529
Mechanical Robustness
  • vibrations contactor open 2 Gn, 5...300 Hz)
  • shocks contactor open 8 Gn for 11 ms)
  • vibrations contactor closed 3 Gn, 5...300 Hz)
  • shocks contactor closed 10 Gn for 11 ms)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 85 mm
Depth 130 mm
Permissible Ambient Air Temperature Around The Device
  • -40-60 °C
  • 60-70 °C with derating
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews