Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC1D95L6 – Contactor, TeSys Deca, 3P 95A AC-3,
LC1D95L6
Contactor, TeSys Deca, 3P 95A AC-3, <= 440V, aux 1NO+1NC, 200V AC 60Hz coil
Specifications
[Uc] Control Circuit Voltage 200 V AC 60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application
  • resistive load
  • motor control
Product Or Component Type contactor
Range TeSys
Utilisation Category
  • AC-3
  • AC-3e
  • AC-4
  • AC-1
[Ie] Rated Operational Current
  • 95 A 60 °C) <= 440 V AC-3 power circuit
  • 125 A 60 °C) <= 690 V AC-1 power circuit
Poles Description 3P
Device Short Name LC1D
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contacts
  • 1.5 ms on energisation between NC and NO contacts
Minimum Switching Current 5 mA signalling circuit
Power Dissipation Per Pole
  • 12.5 W AC-1
  • 7.2 W AC-3
Average Impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C signalling circuit
  • 125 A 60 °C power circuit
Control Circuit Voltage Limits
  • 0.3...0.6 Uc -40-70 °C drop-out AC 60 Hz
  • 0.85...1.1 Uc -40-55 °C operational AC 60 Hz
  • 1...1.1 Uc 55-70 °C operational AC 60 Hz
Mounting Support
  • plate
  • rail
Control Circuit Type AC 60 Hz
Safety Reliability Level
  • B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm signalling circuit
Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
Irms Rated Making Capacity
  • 1100 A 440 V AC power circuit IEC 60947
  • 140 A AC signalling circuit IEC 60947-5-1
  • 250 A DC signalling circuit IEC 60947-5-1
Associated Fuse Rating
  • 10 A gG signalling circuit IEC 60947-5-1
  • 160 A gG <= 690 V type 2 power circuit
  • 200 A gG <= 690 V type 1 power circuit
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Inrush Power In Va 220-220 VA 60 Hz 0.75 20 °C)
Pole Contact Composition 3 NO
Connections - Terminals
  • control circuit screw clamp terminals 1 1-4 mm² rigid
  • control circuit screw clamp terminals 2 1-4 mm² rigid
  • control circuit screw clamp terminals 1 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 2 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 1 1-2.5 mm² flexible with cable end
  • control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end
  • power circuit screw terminals 1 4-50 mm² rigid
  • power circuit screw terminals 2 4-25 mm² rigid
  • power circuit screw terminals 1 4-50 mm² flexible without cable end
  • power circuit screw terminals 2 4-25 mm² flexible without cable end
  • power circuit screw terminals 1 4-50 mm² flexible with cable end
  • power circuit screw terminals 2 4-16 mm² flexible with cable end
Coil Technology without built-in suppressor module
Operating Time
  • 20...35 ms closing
  • 6...20 ms opening
Minimum Switching Voltage 17 V signalling circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque
  • control circuit 1.2 N.m screw clamp terminal flat Ø 6 mm
  • control circuit 1.2 N.m screw clamp terminal Philips No 2
  • power circuit 12 N.m screw terminal flat Ø 6 to Ø 8 mm
  • power circuit 12 N.m screw terminal hex (Allen key) 4 mm
  • control circuit 1.2 N.m screw clamp terminal pozidriv No 2
Electrical Durability
  • 1.2 Mcycles 95 A AC-3
  • 1.3 Mcycles 125 A AC-1
Mechanical Durability 10 Mcycles
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Compatibility Code LC1D
Hold-In Power Consumption In Va 22-22 VA 60 Hz 0.3 20 °C)
Overvoltage Category III
Maximum Horse Power Rating
  • 7.5 hp 115 V at AC 60 Hz for 1 phase
  • 15 hp 230/240 V at AC 60 Hz for 1 phase
  • 25 hp 200/208 V at AC 60 Hz for 3 phase
  • 30 hp 230/240 V at AC 60 Hz for 3 phase
  • 60 hp 460/480 V at AC 60 Hz for 3 phase
  • 60 hp 575/600 V at AC 60 Hz for 3 phase
Motor Power Kw
  • 25 kW 220...230 V AC 50 Hz AC-3)
  • 45 kW 380...400 V AC 50 Hz AC-3)
  • 45 kW 415...440 V AC 50 Hz AC-3)
  • 55 kW 500 V AC 50 Hz AC-3)
  • 45 kW 660...690 V AC 50 Hz AC-3)
  • 15 kW 400 V AC 50 Hz AC-4)
  • 25 kW 220...230 V AC 50 Hz AC-3e)
  • 45 kW 380...400 V AC 50 Hz AC-3e)
  • 45 kW 415...440 V AC 50 Hz AC-3e)
  • 55 kW 500 V AC 50 Hz AC-3e)
  • 45 kW 660...690 V AC 50 Hz AC-3e)
[Ui] Rated Insulation Voltage
  • power circuit 1000 V IEC 60947-4-1
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • signalling circuit 690 V IEC 60947-1
  • signalling circuit 600 V CSA
  • signalling circuit 600 V UL
[Icw] Rated Short-Time Withstand Current
  • 1100 A 40 °C - 1 s power circuit
  • 800 A 40 °C - 10 s power circuit
  • 400 A 40 °C - 1 min power circuit
  • 135 A 40 °C - 10 min power circuit
  • 140 A - 100 ms signalling circuit
  • 120 A - 500 ms signalling circuit
  • 100 A - 1 s signalling circuit
Heat Dissipation 6-10 W 60 Hz control circuit
Protective Cover with
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP110205EN
Sustainable Offer Status Green Premium product
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive Compliant
Product Certifications
  • IECEE CB Scheme
  • UL
  • CSA
  • CCC
  • EAC
  • LROS (Lloyds register of shipping)
  • RINA
  • BV
  • DNV-GL
Height 127 mm
Standards
  • EN/IEC 60947-1
  • EN/IEC 60947-4-1
  • EN/IEC 60947-5-1
  • UL 60947-4-1
  • UL 60947-5-1
  • CSA C22.2 No 60947-4-1
  • CSA C22.2 No 60947-5-1
  • GB/T 14048.4
Climatic Withstand IACS E10 exposure to damp heat
Net Weight 1.61 kg
Flame Retardance V1 conforming to UL 94
Protective Treatment TH 3)IEC 60068-2-30
Ip Degree Of Protection IP20 IEC 60529
Mechanical Robustness
  • shocks contactor opened 8 Gn for 11 ms)
  • shocks contactor closed 10 Gn for 11 ms)
  • vibrations contactor opened 2 Gn, 5...300 Hz)
  • vibrations contactor closed 3 Gn, 5...300 Hz)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 85 mm
Depth 130 mm
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews