Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC1D65004G6 – IEC contactor, TeSys D, nonreversing, 80A resistive, 4 pole, 4 NO, 120VAC 60Hz coil, open style
LC1D65004G6
IEC contactor, TeSys D, nonreversing, 80A resistive, 4 pole, 4 NO, 120VAC 60Hz coil, open style

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 120 VAC 60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.17 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
[Uc] Control Circuit Voltage 120 V AC 60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application resistive load
Product Or Component Type contactor
Utilisation Category
  • AC-1
  • AC-3
  • AC-3e
  • AC-4
[Ie] Rated Operational Current 80 A 60 °C) AC AC-1 power circuit
Poles Description 4P
Device Short Name LC1D
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contacts
  • 1.5 ms on energisation between NC and NO contacts
Minimum Switching Current 5 mA control circuit
Power Dissipation Per Pole 6.4 W AC-1
Average Impedance 1 mOhm - Ith 80 A 50 Hz power circuit
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C control circuit
  • 80 A 60 °C power circuit
Control Circuit Voltage Limits
  • 0.3...0.6 Uc 60-60 °C drop-out AC 60 Hz
  • 0.85...1.1 Uc 60-60 °C operational AC 60 Hz
Mounting Support
  • plate
  • rail
Control Circuit Type AC 60 Hz standard
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm control circuit
Rated Breaking Capacity 1000 A 440 V power circuit IEC 60947
Irms Rated Making Capacity
  • 1000 A 440 V power circuit IEC 60947
  • 140 A AC control circuit IEC 60947-5-1
Associated Fuse Rating
  • 10 A gG control circuit IEC 60947-5-1
  • 125 A gG <= 690 V type 1 power circuit
  • 125 A gG <= 690 V type 2 power circuit
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Inrush Power In Va 140-140 VA 0.75 20 °C)
Pole Contact Composition 4 NO
Connections - Terminals
  • control circuit screw clamp terminal 1 1-4 mm² solid without cable end
  • control circuit screw clamp terminal 2 1-4 mm² flexible without cable end
  • control circuit screw clamp terminal 2 1-4 mm² solid without cable end
  • power circuit screw clamp terminal 1 1-35 mm² solid without cable end
  • power circuit screw clamp terminal 2 1-25 mm² solid without cable end
Coil Technology without built-in bidirectional peak limiting diode suppressor
Operating Time
  • 12...26 ms closing
  • 4...19 ms opening
Minimum Switching Voltage 17 V control circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque
  • control circuit 1.2 N.m screw clamp terminal flat Ø 6 mm
  • control circuit 1.2 N.m screw clamp terminal Philips No 2
  • power circuit 5 N.m screw clamp terminal flat Ø 6 mm
  • power circuit 5 N.m screw clamp terminal flat Ø 8 mm
  • control circuit 1.2 N.m screw clamp terminal pozidriv No 2
  • power circuit 5 N.m screw clamp terminal pozidriv No 2
Mechanical Durability 6000000 cycles
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Compatibility Code LC1D
Hold-In Power Consumption In Va
  • 13-13 VA 50 Hz 0.3 20 °C)
  • 15-15 VA 60 Hz 0.3 20 °C)
Overvoltage Category III
Maximum Horse Power Rating
  • 10 hp 230/240 V at AC 60 Hz for 1 phase conforming to CSA
  • 10 hp 230/240 V at AC 60 Hz for 1 phase conforming to UL
  • 20 hp 200/208 V at AC 60 Hz for 3 phase conforming to CSA
  • 20 hp 200/208 V at AC 60 Hz for 3 phase conforming to UL
  • 20 hp 230/240 V at AC 60 Hz for 3 phase conforming to CSA
  • 20 hp 230/240 V at AC 60 Hz for 3 phase conforming to UL
  • 5 hp 115 V at AC 60 Hz for 1 phase conforming to CSA
  • 5 hp 115 V at AC 60 Hz for 1 phase conforming to UL
  • 50 hp 460/480 V at AC 60 Hz for 3 phase conforming to CSA
  • 50 hp 460/480 V at AC 60 Hz for 3 phase conforming to UL
  • 50 hp 575/600 V at AC 60 Hz for 3 phase conforming to CSA
  • 50 hp 575/600 V at AC 60 Hz for 3 phase conforming to UL
[Ui] Rated Insulation Voltage
  • control circuit 600 V CSA
  • control circuit 600 V UL
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • control circuit 690 V IEC 60947-1
  • power circuit 690 V IEC 60947-1
Heat Dissipation 4-5 W 50/60 Hz control circuit
Protective Cover with
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1503009EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile ENVEOLI1503009EN
Eu Rohs Directive Compliant
Product Certifications
  • DNV
  • LROS (Lloyds register of shipping)
  • RINA
  • UL
  • CCC
  • CSA
  • GOST
  • GL
  • BV
  • UKCA
Height 127 mm
Standards
  • EN 60947-5-1
  • IEC 60947-4-1
  • UL 508
  • EN 60947-4-1
  • CSA C22.2 No 14
  • IEC 60947-5-1
Net Weight 1.44 kg
Flame Retardance V1 conforming to UL 94
Protective Treatment TH 3)IEC 60068
Ip Degree Of Protection
  • IP2X IEC 60529
  • IP2X VDE 0106
Mechanical Robustness
  • shocks contactor open 8 Gn for 11 ms)
  • shocks contactor closed 10 Gn for 11 ms)
  • vibrations contactor opened 2 Gn, 5...300 Hz)
  • vibrations contactor closed 3 Gn, 5...300 Hz)
Operating Altitude 9842.52 ft (3000 m) without derating
Fire Resistance 850 °C IEC 60695-2-1
Width 85 mm
Depth 130 mm
Permissible Ambient Air Temperature Around The Device
  • -5-60 °C
  • -40-70 °C at Uc
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews