TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.81 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
[Uc] Control Circuit Voltage
  • 24...60 V AC 50/60 Hz
  • 24...60 V DC
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application
  • motor control
  • resistive load
Product Or Component Type contactor
Range
  • TeSys
  • TeSys Deca
Utilisation Category
  • AC-1
  • AC-3
  • AC-3e
[Ie] Rated Operational Current
  • 9 A 60 °C) <= 440 V AC-3 power circuit
  • 25 A 60 °C) <= 440 V AC-1 power circuit
  • 9 A 60 °C) <= 440 V AC-3e power circuit
Poles Description 3P
Device Short Name LC1D
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA signalling circuit
Power Dissipation Per Pole
  • 1.56 W AC-1
  • 0.2 W AC-3
  • 0.2 W AC-3e
Average Impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C signalling circuit
  • 25 A 60 °C power circuit
Control Circuit Voltage Limits
  • <= 0.1 Uc -40-70 °C drop-out AC/DC
  • 0.85...1.1 Uc -40-60 °C operational AC
  • 0.8...1.1 Uc -40-60 °C operational DC
  • 1...1.1 Uc 60-70 °C operational AC/DC
Mounting Support
  • rail
  • plate
Control Circuit Type AC/DC 50/60 Hz AC/DC electronic
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pollution Degree 3
Hold-In Power Consumption In W 0.6-0.6 W 20 °C
Insulation Resistance > 10 MOhm signalling circuit
Rated Breaking Capacity 250 A 440 V power circuit IEC 60947
Irms Rated Making Capacity
  • 250 A 440 V power circuit IEC 60947
  • 140 A AC signalling circuit IEC 60947-5-1
  • 250 A DC signalling circuit IEC 60947-5-1
Associated Fuse Rating
  • 10 A gG signalling circuit IEC 60947-5-1
  • 25 A gG <= 690 V type 1 power circuit
  • 20 A gG <= 690 V type 2 power circuit
Inrush Power In Va 15-15 VA 50/60 Hz 20 °C)
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Pole Contact Composition 3 NO
Connections - Terminals
  • control circuit screw clamp terminals 1 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 2 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 1 1-4 mm² flexible with cable end
  • control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end
  • control circuit screw clamp terminals 1 1-4 mm² solid
  • control circuit screw clamp terminals 2 1-4 mm² solid
  • power circuit screw clamp terminals 1 1-4 mm² flexible without cable end
  • power circuit screw clamp terminals 2 1-4 mm² flexible without cable end
  • power circuit screw clamp terminals 1 1-4 mm² flexible with cable end
  • power circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end
  • power circuit screw clamp terminals 1 1-4 mm² solid
  • power circuit screw clamp terminals 2 1-4 mm² solid
Coil Technology built-in bidirectional peak limiting
Operating Time
  • 45...55 ms closing
  • 20...90 ms opening
Minimum Switching Voltage 17 V signalling circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Signalling Circuit Frequency 25...400 Hz
Tightening Torque
  • control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • control circuit 1.7 N.m screw clamp terminals Philips No 2
  • power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • power circuit 1.7 N.m screw clamp terminals Philips No 2
  • power circuit 1.7 N.m screw clamp terminals pozidriv No 2
  • control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Electrical Durability
  • 2.4 Mcycles 8 A AC-3 <= 440 V
  • 0.6 Mcycles 25 A AC-1 <= 440 V
  • 2.4 Mcycles 8 A AC-3e <= 440 V
Mechanical Durability 15 Mcycles
Inrush Power In W 14-14 W 20 °C)
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Compatibility Code LC1D
Hold-In Power Consumption In Va 0.9-0.9 VA 50/60 Hz 20 °C)
Overvoltage Category III
Maximum Horse Power Rating
  • 0.33 hp 115 V at AC 60 Hz for 1 phase
  • 1 hp 230/240 V at AC 60 Hz for 1 phase
  • 2 hp 200/208 V at AC 60 Hz for 3 phase
  • 2 hp 230/240 V at AC 60 Hz for 3 phase
  • 5 hp 460/480 V at AC 60 Hz for 3 phase
  • 7.5 hp 575/600 V at AC 60 Hz for 3 phase
Motor Power Kw
  • 2.2 kW 220...230 V AC 50 Hz AC-3)
  • 4 kW 380...400 V AC 50 Hz AC-3)
  • 4 kW 415 V AC 50 Hz AC-3)
  • 4 kW 440 V AC 50 Hz AC-3)
  • 5.5 kW 500 V AC 50 Hz AC-3)
  • 5.5 kW 660...690 V AC 50 Hz AC-3)
  • 2.2 kW 220...230 V AC 50 Hz AC-3e)
  • 4 kW 380...400 V AC 50 Hz AC-3e)
  • 4 kW 415 V AC 50 Hz AC-3e)
  • 4 kW 440 V AC 50 Hz AC-3e)
  • 5.5 kW 500 V AC 50 Hz AC-3e)
  • 5.5 kW 660...690 V AC 50 Hz AC-3e)
[Ui] Rated Insulation Voltage
  • power circuit 690 V IEC 60947-4-1
  • signalling circuit 690 V IEC 60947-1
[Icw] Rated Short-Time Withstand Current
  • 100 A - 1 s signalling circuit
  • 120 A - 500 ms signalling circuit
  • 140 A - 100 ms signalling circuit
  • 30 A 40 °C - 10 min power circuit
  • 61 A 40 °C - 1 min power circuit
  • 105 A 40 °C - 10 s power circuit
  • 210 A 40 °C - 1 s power circuit
Heat Dissipation 0.6-0.6 W 50/60 Hz
Protective Cover with
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1609001EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile ENVEOLI1609001EN
Eu Rohs Directive Compliant
Halogen Content Performance Halogen free plastic parts & cables product
Product Certifications
  • CCC
  • CSA
  • EAC
  • UL
  • KC
  • DNV-GL
  • LROS (Lloyds register of shipping)
  • UKCA
Height 77 mm
Standards
  • EN/IEC 60947-4-1
  • EN/IEC 60947-5-1
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1
  • IEC 60335-1
Climatic Withstand
  • IACS E10 exposure to damp heat
  • IEC 60947-1 Annex Q category D exposure to damp heat
Net Weight 0.368 kg
Flame Retardance V1 conforming to UL 94
Ip Degree Of Protection IP20 front face IEC 60529
Mechanical Robustness
  • vibrations contactor open 2 Gn, 5...300 Hz)
  • vibrations contactor closed 4 Gn, 5...300 Hz)
  • shocks contactor open 10 Gn for 11 ms)
  • shocks contactor closed 15 Gn for 11 ms)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 45 mm
Depth 86 mm
Permissible Ambient Air Temperature Around The Device
  • -40-60 °C
  • 60-70 °C with derating
Documents
Royal Wholesale Electric

5.0

Powered by