Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
JLL36175LV – Circuit breaker, PowerPacT J, 175A, 3 pole, 600VAC, 50kA, lugs, thermal magnetic, 80%, control wire OFF end
JLL36175LV
Circuit breaker, PowerPacT J, 175A, 3 pole, 600VAC, 50kA, lugs, thermal magnetic, 80%, control wire OFF end

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 175A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a control wire terminal on the load end. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Or Component Type circuit breaker
Warranty 18 months
Circuit Breaker Application HACR rated
Mounting Mode unit mount lug)
Network Frequency 50/60 Hz
Wire Stripping Length 25 mm
Terminal Identifier AL175JD
Line Rated Current 175-175 A
Utilisation Category category A
[Ics] Rated Service Breaking Capacity
  • 125 kA 220/240 V AC 50/60 Hz IEC 60947-2
  • 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2
  • 50 kA 500/525 V AC 50/60 Hz IEC 60947-2
  • 20 kA 250 V DC IEC 60947-2
  • 20 kA 500 V DC IEC 60947-2
Long Time Pick-Up Adjustment Range 0.25...1 x In
Trip Unit Technology thermal-magnetic
Height 191 mm
Continuous Current Rating 80 %
Breaking Capacity
  • 125 kA 240 V AC 50/60 Hz UL 489
  • 100 kA 480 V AC 50/60 Hz UL 489
  • 50 kA 600 V AC 50/60 Hz UL 489
  • 20 kA 250 V DC UL 489
  • 50 kA 500 V DC UL 489
[Ui] Rated Insulation Voltage 750 V IEC 60947-2
Suitability For Isolation yes IEC 60947-2
Communication Interface Modbus
[Ue] Rated Operational Voltage 600 V AC 50/60 Hz IEC 60947-3
Tightening Torque 25-25 N.m 25-95 mm² (AWG 4...AWG 4/0)
Mounting Support lug
Breaking Capacity Code L
Accessory / Separate Part Type control wire OFF end
Magnetic Tripping Current 1750-1750 A
Poles Description 3P
Local Signalling switched off (OFF) 1 trip indicator green)
Number Of Slots
  • 2 auxiliary switch OF plug-in)
  • 1 alarm switch SD plug-in)
  • 1 overcurrent trip switch SDE plug-in)
  • 1 voltage release MN or MX plug-in)
Protection Type
  • overload protection
  • short-circuit protection
Awg Gauge AWG 4...AWG 4/0 aluminium/copper terminal
Width 104 mm
Electrical Connection
  • lugs line
  • lugs load
Depth 86 mm
Net Weight 2.4 kg
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
Magnetic Hold Current 875 A
Control Type toggle
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile ENVEOLI2206031EN
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP2206031EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Eu Rohs Directive Compliant
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Ambient Air Temperature For Operation -2-70 °C
Pollution Degree 3
Ambient Air Temperature For Storage -50-85 °C
Standards
  • UL
  • CSA
  • NEMA
  • NOM-003-SCFI-2000
  • IEC 60947-2
Quality Labels CE
Product Certifications
  • UL
  • CSA
  • NOM
Operating Altitude
  • < 6561.68 ft (2000 m) without derating
  • 5000 m with derating
Ip Degree Of Protection front cover IP40
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews