EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of 1/2 inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
Brand: Schneider Electric
Add to Quote CatalogueRange Of Product | Square D |
---|---|
Product Or Component Type | DOE 2016 energy efficient transformer |
Transformer Type | energy efficient |
Device Application | low voltage electrical distribution |
Device Short Name | DOE 2016 |
Tap Loss |
|
Network Frequency | 60 Hz |
Primary Voltage | 480 V delta |
Percentage Impedance Voltage | 3.27 % |
Height | 953 mm |
Number Of Mounting Holes | 4 Ø: 13 mm |
[Uimp] Rated Impulse Withstand Voltage | 10 kV |
Primary Operational Current | 135.32-135.32 A 312.27 A 112.5 kVA |
Temperature Rise |
|
Degree Of Protection |
|
Number Of Tap-Offs |
|
X/R Ratio | 1.39 |
Rated Operational Power In Va | 112.5 kVA |
Electrical Connection |
|
Phase | 3 phase |
Material | copper |
Net Weight | 441.80 kg |
Secondary Voltage | 208Y/120 V |
Percentage Reactance | 2.67 % |
Noise Level |
|
Type Of Cooling | natural convection |
Efficiency | 98.80 % at 35 % load factor , 75.0 °C |
Mounting Support |
|
Continuous Thermal Current Rating Factor |
|
Width | 795 mm |
Depth | 722 mm |
Inrush Current | 1563 A |
Box Number | 21M |
[Ipk] Rated Peak Withstand Current | 9.55 kA |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1604027EN |
Sustainable Offer Status | Green Premium product |
Pvc Free | Yes |
Toxic Heavy Metal Free | Yes |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
China Rohs Regulation | Pro-active China RoHS declaration (out of China RoHS legal scope) |
Eu Rohs Directive | Compliant |
Average Ambient Air Temperature For Operation | 30 °C |
Ambient Air Temperature For Operation | 40-40 °C |