EXN112T3155H – Low voltage transformer, DOE 2016, dry type, 3 phase, 112.5kVA, 208V pri, 480/277V sec, Al, 150C rise, Type 2
EXN112T3155H
Low voltage transformer, DOE 2016, dry type, 3 phase, 112.5kVA, 208V pri, 480/277V sec, Al, 150C rise, Type 2

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 208V primary (three wire), 480Y/277V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of 1/2 inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Transformer Type energy efficient
Range Of Product Square D
Product Or Component Type DOE 2016 energy efficient transformer
Device Application low voltage electrical distribution
Device Short Name DOE 2016
Tap Loss
  • 221 no load (core loss)
  • 2683 load loss (coil loss)
Primary Voltage 208 V delta
Network Frequency 60 Hz
Percentage Impedance Voltage 3.67 %
Percentage Reactance 3.00 %
Noise Level
  • 44 dB
  • 6 dB NEMA ST-20
Height 953 mm
Number Of Mounting Holes 4 Ø: 13 mm
[Uimp] Rated Impulse Withstand Voltage 10 kV
Type Of Cooling natural convection
Primary Operational Current 270.63-270.63 A 135.32 A 112.5 kVA
Efficiency 98.77 % at 35 % load factor , 75.0 °C
Mounting Support
  • floor
  • floor, with 7400FMB
  • ceiling, with 7400CMB21M
Temperature Rise
  • 150 °C
  • 220 °C insulated
Degree Of Protection
  • UL type 2
  • UL type 3R, with 7400WS21M
X/R Ratio 1.59
Continuous Thermal Current Rating Factor
  • 1008 16.6 %
  • 1326 25 %
  • 3043 50 %
  • 5904 75 %
  • 9909 100 %
Width 795 mm
Depth 722 mm
Inrush Current 3031 A
Rated Operational Power In Va 112.5 kVA
Electrical Connection
  • 4 Hole Nema Pad secondary 11.1 mm
  • 6 Hole Nema Pad sec - HO 11.1 mm
  • 4 Hole Nema Pad primary 11.1 mm
Phase 3 phase
Material aluminium
Net Weight 333.39 kg
Secondary Voltage 480Y/277 V
Box Number 21M
[Ipk] Rated Peak Withstand Current 3.69 kA
Average Ambient Air Temperature For Operation 30 °C
Ambient Air Temperature For Operation 40-40 °C
Standards
  • UL 1561
  • CSA C22.2 No 47
  • NEMA ST-20