Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
EX300T3HIS – Low Voltage Transformer, DOE 2016, 3 Phase, 300 kVA, 480V Delta primary / 208Y/120V secondary, AL, 150°C Rise, Shielded
EX300T3HIS
Low Voltage Transformer, DOE 2016, 3 Phase, 300 kVA, 480V Delta primary / 208Y/120V secondary, AL, 150°C Rise, Shielded

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 300kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 99.02% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of 1/2 inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Range Of Product Square D
Device Application low voltage electrical distribution
Network Frequency 60 Hz
Primary Voltage 480 V delta
Percentage Impedance Voltage 0.051 %
Percentage Reactance 0.0487 %
[Uimp] Rated Impulse Withstand Voltage 10.0 kV
Type Of Cooling natural convection
Number Of Tap-Offs
  • 2 2.5 % FCAN
  • 4 2.5 % FCBN
Rated Operational Power In Va 300 kVA
Phase 3 phase
Material aluminium
Secondary Voltage 208Y/120 V
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1604028EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Toxic Heavy Metal Free Yes
Eu Rohs Directive Compliant
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Halogen Content Performance Halogen free plastic parts product
Reach Free Of Svhc Yes
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews