EX15T3HFNLP – Low voltage transformer, DOE 2016, dry type, 3 phase, 15kVA, 480V delta pri, 208Y/120V sec, Al, 115C rise, Type 1, K13
EX15T3HFNLP
Low voltage transformer, DOE 2016, dry type, 3 phase, 15kVA, 480V delta pri, 208Y/120V sec, Al, 115C rise, Type 1, K13

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 15kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 115 degree C temperature rise, K-13 rated. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 97.89% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of 1/2 inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Range Of Product Square D
Product Or Component Type transformer
Transformer Type energy efficient
Device Application low voltage electrical distribution
Device Short Name DOE 2016
Tap Loss
  • 69.0 no load (core loss)
  • 238.0 load loss (coil loss)
Primary Voltage 480 V delta
Network Frequency 60 Hz
Percentage Impedance Voltage 0.018 %
Height 897 mm
[Uimp] Rated Impulse Withstand Voltage 10 kV
Temperature Rise
  • 115 °C
  • 220 °C insulated
Degree Of Protection
  • UL type 1
  • UL type 2, with 7400DS18K
  • UL type 3R, with 7400WS18K
Number Of Tap-Offs
  • 2 2.5 % FCAN
  • 4 2.5 % FCBN
X/R Ratio 0.49
Rated Operational Power In Va 15 kVA
Electrical Connection
  • 2 Hole Nema Pad primary 11.1 mm
  • 2 Hole Nema Pad secondary 11.1 mm
  • 4 Hole Nema Pad sec - XO 11.1 mm
Phase 3 phase
Material aluminium
Net Weight 181.44 kg
Secondary Voltage 208Y/120 V
Percentage Reactance 0.0078 %
Noise Level
  • 6 dB NEMA ST-20
  • 39 dB
Type Of Cooling natural convection
Efficiency 98.24 % at 35 % load factor , 75.0 °C
Mounting Support
  • floor
  • floor, with 7400FMB
  • ceiling, with 7400CMB18K
  • wall, with 7400WMB18K20K
Continuous Thermal Current Rating Factor
  • 257.805015136 16.6 %
  • 286.18149999999997 25 %
  • 438.442 50 %
  • 692.2094999999999 75 %
  • 1047.484 1.0 %
Width 648 mm
Depth 533 mm
[Ipk] Rated Peak Withstand Current 2.4 kA
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1604028EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive Compliant
Halogen Content Performance Halogen free plastic parts product
Average Ambient Air Temperature For Operation 30 °C
Ambient Air Temperature For Operation 40-40 °C
Standards
  • UL 1561
  • CSA C22.2 No 47
  • NEMA ST-20