Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
EMS59300 – Easergy LV150: low voltage power rmonitoring and transformer thermal monitoring
EMS59300
PowerLogic LV150: low voltage power monitoring and transformer thermal monitoring

The Easergy LV150 is an unmatched low voltage monitoring module designed for the public MV/LV substation. The main functions of LV150 are: transformer temperature monitoring, LV incomer power and quality monitoring, LV network voltage fault detection. It offers class 0.5 current and voltage, and class 1 energy system accuracy. The degree of protection is IP2x body and IP4x in the front. The degree of protection is IK07. It complies with CE certificat. The operating temperature is -40°C to + 70°C. The storage temperature is -40°C to + 85°C. It include 8 gigital inputs, and communication port ethernet 2 RJ45. The device dimensions are 45mm in width, 140mm in height, 140 in depth, and weight 0.46 kilograms.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Range Of Product Easergy T300
Device Short Name LV150
Communication Port Support 2 ETHERNET RJ45
Measurement Voltage single or three phases)0-30 V AC 50/60 Hz
Memory Capacity 4 MB
Protection Type
  • ANSI 47 : negative sequence overvoltage
  • ANSI 27 : undervoltage
  • ANSI 59 : overvoltage
  • ANSI 59N : neutral voltage displacement
  • ANSI 37 : phase undercurrent
Type Of Measurement
  • active and reactive energy
  • power factor
  • current
  • voltage
  • frequency
  • active and reactive power
  • apparent energy
  • apparent power
Product Or Component Type low voltage and transformer monitoring
Measurement Current
  • 5-5 A
  • 1-1 A
Number Of Inputs 8 digital IEC 61131-2 type 3
[Us] Rated Supply Voltage 12...48 V DC +/- 20 %
Communication Port Protocol IEC 60870-5-104
Power Consumption In Va 2 VA
Software Function
  • assistance in commissioning and operating the installation
  • alarm
  • reports and diagrams
  • security/authority verification
  • Operating/Status report
  • event log
Control Type status illuminated push-button
Data Recording
  • sequence of event recording
  • sag and swell logs
  • counter
  • harmonics logs
  • event logs
  • demand values
  • min/max of instantaneous values
  • current value before fault
Analogue Input Type 4 current 0.01...35 A 0.001 Ohm)
Type Of Measurement
  • current class 0.5
  • voltage class 0.5
  • energy class 1 IEC 61557-12
Synchronisation Time Between Inputs 1 ms
Power Quality Analysis
  • voltage sag and swell detection
  • voltage unbalance
  • individual harmonics
  • harmonic distortion
  • voltage magnitude
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1605007
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1605007
Eu Rohs Directive Compliant
Product Certifications CE
Ik Degree Of Protection IK07 IEC 62262
Ambient Air Temperature For Operation -40-70 °C
Height 140 mm
Standards
  • IEC 60255-27
  • IEC 61557-12
  • IEC 62586-1
  • IEC 61000-4-30:class S
  • IEC 61850
Electromagnetic Compatibility
  • electrical fast transient/burst immunity test level 4criteria A IEC 61000-4-4
  • conducted RF disturbances level 3criteria A IEC 61000-4-6
  • conducted disturbance emission level 4criteria A IEC 61000-4-16
  • 100 kHz damped oscillating wave level 3criteria A IEC 61000-4-12
  • radiated radio-frequency electromagnetic field immunity test level 4criteria A IEC 61000-4-3
  • immunity to voltage dipscriteria A IEC 61000-4-29
  • electrostatic discharge level 4criteria B IEC 61000-4-2
  • surge immunity test level 3criteria A IEC 61000-4-5
  • magnetic field at power frequency level 5criteria B IEC 61000-4-8
  • conducted and radiated emissionsclass A EN 55022
Net Weight 0.46 kg
Fixing Mode clip-in DIN rail)
Ambient Air Temperature For Storage -40-85 °C
Relative Humidity 5-95 % IEC 60068-2-30
Ip Degree Of Protection
  • body IP2X IEC 60529
  • front IP4X IEC 60529
Type Of Installation
  • indoor
  • outdoor in cabinet
Mechanical Robustness
  • vibrations 10-2000 Hz 1 gn 10 cycles IEC 60068-2-6
  • bumps 10 gn 16 ms 1000 bumps non energized IEC 60068-2-29
  • shocks 10 gn 11 ms 3 pulses in operation IEC 60068-2-27
Width 45 mm
Depth 140 mm
Operating Altitude 9842.52 ft (3000 m)