Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
EGB34020SA – Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277 VAC, 65 kA max, bolt on, shunt trip
EGB34020SA
Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277 VAC, 65 kA max, bolt on, shunt trip

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Module Type E-Frame
Range Of Product 125 A Frame EDB-EGB-EJB
Trip Unit Rating 875-875 A
Product Or Component Type miniature circuit-breaker
Device Short Name EGB
Warranty 18 months
Height 5.66 in
Holding Current 270 A
Tightening Torque 3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Breaking Capacity Code G
Product Destination NF panelboard
Electrical Connection lugs aluminium
Number Of Spaces Required 4
Number Of Spaces 4
Net Weight 4 lb(US)
Circuit Breaker Application
  • HACR rated
  • HID rated
Mounting Mode bolt-on
Line Rated Current 20 A
Protection Type
  • overload
  • short-circuit
Local Signalling trip indicator
Awg Gauge
  • AWG 12...AWG 6 aluminium
  • AWG 14...AWG 6 copper
Width 3.92 in
Depth 4.05 in
Device Composition shunt trip
Breaking Capacity
  • 35 kA 277 V AC
  • 65 kA 240 V AC
  • 35 kA 480Y/277 V AC
  • 65 kA 120 V AC
  • 65 kA 120/240 V AC
Trip Unit Technology thermal-magnetic
Number Of Poles 3
[Ue] Rated Operational Voltage 480Y/277 V AC
Rohs Exemption Information Yes
Mercury Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications cULus
Ambient Air Temperature For Operation 40 °C
Documents