E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This device is a 2 pole bolt-on breaker that is rated at 60 A at a system voltage of 480Y/277 VAC and the breaker is UL Listed as well as CSA rated. This E-Frame breaker has thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. This specific breaker is HACR rated. The breaker has aluminium lugs which have a terminal lug rating of AWG 12...AWG 2/0 (aluminium) and AWG 14...AWG 2/0 (copper). This E-frame breaker breaking capacity has been tested a numerous voltages but at two voltages the capacity is 18 kA at 480Y/277 VAC and 25 kA at 120/240 VAC. This device has a hold current of 630 A which is the maxiumum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. The circuit breaker has a height of 5.66 in, width of 1.96 in and a depth of 4.05 in. This breaker was calibrated for 40 degrees C. HACR rated.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Module Type E-Frame
Range Of Product 125 A Frame EDB-EGB-EJB
Trip Unit Rating 2300-2300 A
Product Or Component Type miniature circuit-breaker
Device Short Name EDB
Warranty 18 months
Height 5.66 in
Holding Current 1000 A
Tightening Torque
  • 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10)
  • 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Breaking Capacity Code D
Product Destination NF panelboard
Electrical Connection lugs aluminium
Number Of Spaces Required 3
Number Of Spaces 3
Net Weight 4 lb(US)
Circuit Breaker Application HACR rated
Mounting Mode bolt-on
Line Rated Current 100 A
Protection Type
  • overload
  • short-circuit
Local Signalling trip indicator
Awg Gauge
  • AWG 12...AWG 2/0 aluminium
  • AWG 14...AWG 2/0 copper
Width 3.92 in
Depth 4.05 in
Breaking Capacity
  • 18 kA 277 V AC
  • 25 kA 240 V AC
  • 18 kA 480Y/277 V AC
  • 25 kA 120 V AC
  • 25 kA 120/240 V AC
Trip Unit Technology thermal-magnetic
Number Of Poles 3
[Ue] Rated Operational Voltage 480Y/277 V AC
Rohs Exemption Information Yes
Mercury Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications cULus
Ambient Air Temperature For Operation 50 °C
Documents