Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
DPE32G7 – IEC contactor,Easy TeSys DPE,nonreversing,32A,3P,15HP at 480V AC,120V 50/60Hz coil
DPE32G7
IEC contactor,Easy TeSys DPE,nonreversing,32A,3P,15HP at 480V AC,120V 50/60Hz coil

Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15 HP@480V). It provides a 120V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
[Uc] Control Circuit Voltage 120 V AC 50/60 Hz
Auxiliary Contact Composition 1 NO
Contactor Application
  • resistive load
  • motor control
Product Or Component Type contactor
Product Name Easy TeSys DPE
Range Easy TeSys
Pole Contact Composition 3 NO
Utilisation Category
  • AC-4
  • AC-1
  • AC-3
[Ie] Rated Operational Current
  • 32 A 60 °C) <= 440 V AC AC-3 power circuit
  • 40 A 60 °C) <= 440 V AC AC-1 power circuit
Poles Description 3P
Maximum Horse Power Rating
  • 2 hp 115 V at AC 50/60 Hz for 1 phase
  • 3 hp 230/240 V at AC 50/60 Hz for 1 phase
  • 7.5 hp 200/208 V at AC 50/60 Hz for 3 phase
  • 7.5 hp 230/240 V at AC 50/60 Hz for 3 phase
  • 15 hp 460/480 V at AC 50/60 Hz for 3 phase
  • 20 hp 575/600 V at AC 50/60 Hz for 3 phase
Motor Power Kw
  • 7.5 kW 220...230 V AC 50/60 Hz
  • 15 kW 380...400 V AC 50/60 Hz
  • 15 kW 415 V AC 50/60 Hz
  • 15 kW 440 V AC 50/60 Hz
  • 18.5 kW 500 V AC 50/60 Hz
  • 18.5 kW 660...690 V AC 50/60 Hz
Device Short Name DPE
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA signalling circuit
[Ue] Rated Operational Voltage
  • power circuit <= 690 V AC 25...400 Hz
  • power circuit <= 300 V DC
Height 85 mm
Power Dissipation Per Pole
  • 3.2 W AC-1
  • 1.25 W AC-3
Average Impedance 2 mOhm - Ith 40 A 50 Hz power circuit
Control Circuit Voltage Limits
  • drop-out 0.3...0.6 Uc 50/60 Hz 70 °C)
  • operational 0.8...1.1 Uc 50 Hz 60 °C)
  • operational 0.85...1.1 Uc 60 Hz 60 °C)
  • operational 1...1.1 Uc 50/60 Hz 70 °C)
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C signalling circuit
  • 40 A 60 °C power circuit
Mounting Support
  • rail
  • plate
Control Circuit Type AC 50/60 Hz
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm signalling circuit
Rated Breaking Capacity 450 A 440 V power circuit IEC 60947
Irms Rated Making Capacity
  • 140 A AC signalling circuit IEC 60947-5-1
  • 250 A DC signalling circuit IEC 60947-5-1
  • 450 A 440 V power circuit IEC 60947
Associated Fuse Rating
  • 10 A gG signalling circuit IEC 60947-5-1
  • 63 A gG <= 690 V type 1 power circuit
  • 40 A gG <= 690 V type 2 power circuit
Net Weight 0.37 kg
Inrush Power In Va
  • 70-70 VA 60 Hz 0.75 20 °C)
  • 70-70 VA 50 Hz 0.75 20 °C)
Connections - Terminals
  • power circuit screw clamp terminals 1 1-4 mm² flexible without cable end
  • power circuit screw clamp terminals 2 1-4 mm² flexible without cable end
  • power circuit screw clamp terminals 1 1-4 mm² flexible with cable end
  • power circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end
  • power circuit screw clamp terminals 1 1-4 mm² solid without cable end
  • power circuit screw clamp terminals 2 1-4 mm² solid without cable end
  • control circuit screw clamp terminals 1 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 2 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 1 1-4 mm² flexible with cable end
  • control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end
  • control circuit screw clamp terminals 1 1-4 mm² solid without cable end
  • control circuit screw clamp terminals 2 1-4 mm² solid without cable end
Coil Technology without built-in suppressor module
Minimum Switching Voltage 17 V signalling circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Signalling Circuit Frequency 25...400 Hz
Tightening Torque
  • power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • power circuit 1.7 N.m screw clamp terminals Philips No 2
  • control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • control circuit 1.7 N.m screw clamp terminals Philips No 2
Electrical Durability
  • 1 Mcycles 32 A AC-3 <= 440 V
  • 0.6 Mcycles 40 A AC-1 <= 440 V
Mechanical Durability 10 Mcycles
Auxiliary Contacts Type mechanically linked 1 NO IEC 60947-5-1
Hold-In Power Consumption In Va
  • 7.5-7.5 VA 60 Hz 0.3 20 °C)
  • 7-7 VA 50 Hz 0.3 20 °C)
Operating Time
  • 12...22 ms closing
  • 4...19 ms opening
Width 45 mm
Depth 92 mm
Heat Dissipation 2-3 W 50/60 Hz
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1501004
Sustainable Offer Status Green Premium product
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile ENVEOLI1501004
Eu Rohs Directive Compliant
Product Certifications
  • UL
  • CSA
Ambient Air Temperature For Operation -40-60 °C
Standards
  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 60947-4-1
Pollution Degree 3
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Ambient Air Temperature For Storage -60-80 °C
Ip Degree Of Protection IP20 front face IEC 60529
Mechanical Robustness
  • vibrations contactor open 2 Gn, 5...300 Hz)
  • vibrations contactor closed 4 Gn, 5...300 Hz)
  • shocks contactor open 10 Gn for 11 ms)
  • shocks contactor closed 15 Gn for 11 ms)
Operating Altitude 0...6561.68 ft (0...2000 m)
Fire Resistance 850 °C IEC 60695-2-1
Overvoltage Category III
[Ui] Rated Insulation Voltage
  • power circuit 690 V IEC 60947-4-1
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • signalling circuit 690 V IEC 60947-1
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews