Control Circuit Type | AC |
---|---|
[Uc] Control Circuit Voltage | 480 V AC 50/60 Hz |
Contactor Application | control circuit |
Product Or Component Type | control relay |
Product Name | TeSys CAK |
Range | TeSys |
Pole Contact Composition | 2 NO + 2 NC |
Connections - Terminals |
|
Coil Technology | without integral suppression device |
Utilisation Category | AC-15 |
Device Short Name | CA2K |
Coil Type | standard |
Warranty | 18 months |
Non Overlap Distance | 0.5 m |
Non-Overlap Time |
|
[Ue] Rated Operational Voltage | <= 690 V AC <= 400 Hz |
Height | 58 mm |
Control Circuit Voltage Limits |
|
[Ith] Conventional Free Air Thermal Current | 10 A 50 °C |
Insulation Resistance | > 10 MOhm |
Associated Fuse Rating |
|
Net Weight | 0.18 kg |
Inrush Power In Va | 30-30 VA 20 °C) |
[Ui] Rated Insulation Voltage |
|
Flame Retardance |
|
Maximum Operating Rate | 10000 cyc/h 20 °C |
Minimum Switching Current | 5 mA |
Mechanical Durability | 10000000 cycles |
Hold-In Power Consumption In Va | 4.5-4.5 VA 20 °C) |
Operating Time |
|
Width | 45 mm |
Depth | 57 mm |
Tightening Torque | 0.8-1.3 N.m screw clamp terminals 1.5-4 mm² Philips M6 |
Minimum Switching Voltage | 17 V |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1503003EN |
Sustainable Offer Status | Green Premium product |
Toxic Heavy Metal Free | Yes |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | Pro-active China RoHS declaration (out of China RoHS legal scope) |
Circularity Profile | ENVEOLI1503003EN |
Eu Rohs Directive | Compliant |
Product Certifications |
|
Ambient Air Temperature For Operation | -25-50 °C |
Standards |
|
Immunity To Microbreaks | 2 ms |
Shock Resistance |
|
Vibration Resistance |
|
Ip Degree Of Protection | IP2X conforming to VDE 0106 |
Ambient Air Temperature For Storage | -50-80 °C |
Protective Treatment | TC IEC 60068 |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Heat Dissipation | 1.3-1.3 W 50/60 Hz |