This product is part of the Modicon X80 range, a common platform of modules for Modicon M580 and M340 Programmable Automation Controllers (PAC). This PTO module has 2 channels, 4 inputs with sink (positive) discrete logic. It is a PTO module with an input/output voltage 24V DC, an output current of 50mA and a maximum current consumption of 200mA at 3.3V DC. This product is robust, high quality and based on the latest innovative technology. It is furnished with two 28-way connectors for electrical connection. There is no insulation between channels. It is suitable for medium to large process applications. It meets EN 61131-2, EN 61000-6-4, EN 61000-6-2 and EN 61010-2-201 standards. This output compatible with signal converter (USIC), RS422, 7mA input and source input, 5V to 24V. Input compatible with 2-wire/3-wire proximity sensor 19.2V to 30V conforming to IEC 947-5-2. Modicon X80 consists in a compatible modules common platform that reduce maintenance and training costs with same spare parts in stock, and unique training for different Programmable Automation Controllers (PAC).
Brand: Schneider Electric
Add to Quote CatalogueRange Of Product | Modicon X80 |
---|---|
Number Of Inputs | 4 |
Output Compatibility |
|
Product Or Component Type | PTO module |
Output Frequency |
|
Input Compatibility | 2-wire/3-wire proximity sensor 19.2-30 V IEC 947-5-2 |
Number Of Channels | 2 |
Discrete Input Type |
|
Warranty | 18 months |
Electrical Connection | 2 connectors 28 pins |
Current Per Channel | 0.4 A |
Number Of Outputs |
|
Insulation Resistance | > 10 MOhm |
Product Certifications |
|
Response Time |
|
Current Consumption |
|
Discrete Output Current | 50 mA |
Current State 0 Guaranteed | <= 1.5 mA |
Voltage State 0 Guaranteed | 5 V |
Load Impedance Ohmic | 15000 Ohm |
Input Current | 4.3 mA |
Current State 1 Guaranteed | >= 2 mA |
Operating Threshold |
|
Output Short-Circuit Protection | by current limiter and electronic circuit breaker |
Output Voltage Limits | 19...30 V |
Insulation Between Channels | no insulated |
Input Voltage | 24 V DC |
Insul Btwn Prim And Second | 1500 Vrms |
Local Signalling |
|
Output Overload Protection | by current limiter and electronic circuit breaker |
Output Voltage | 24 V DC |
Module Format | standard |
Reverse Polarity Protection |
|
[Ures] Residual Voltage | 0.15 V at state 1 |
Maximum Leakage Current | 0.05 mA at state 0 |
Preactuator Voltage Detection Threshold |
|
Response Time On Output |
|
Voltage State 1 Guaranteed | >= 11 V |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP070204EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI0702004EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Ambient Air Temperature For Operation | -25-70 °C |
Standards |
|
Environmental Characteristic | hazardous location class I division 2 |
Directives |
|
Derating Factor | without |