Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
BMXCPS4022S – redundant power supply module, Modicon X80, 24 to 48V DC, safety
BMXCPS4022S
redundant power supply module, Modicon X80, 24 to 48V DC, safety

This product is part of the Modicon X80 range, a common platform of modules for Modicon M580 and M340 Programmable Automation Controllers (PAC). On the front face of the power supply, 2 connectors (2-way and 5-way) can take a removable terminal block. It converts 24…48 V DC current into 24 V DC and 3.3 V DC output voltages, distributed over the backplane. This safety power supply can provide advanced diagnostics that simplify maintenance by predicting when to replace power supply before it fails. It detects overvoltage, overload, and short-circuit conditions on 24 V DC and 3.3 V DC backplane lines. It can be installed in any rack, main or extended local rack, main or extended remote rack. It has a red coating specific to Safety products. For high-availability applications, two independent redundant power supplies can be used to increase the security of the power supply. This product is certified by CE and UL, and also by ATEX and IECEx for use in explosive atmospheres. The safety power supply is provided with Set of two caged removable terminal blocks. A set of two caged removable terminal blocks (5-way and 2-way) is included in the power supply package. The power supply has to be inserted in the leftmost dedicated slots on each rack (marked CPS). Modicon X80 is a platform of modules common to Modicon M580 and M340 automation platforms that reduces maintenance and training costs with same spare parts in stock, and unique training for various Programmable Automation Controllers (PAC). Modicon X80 consists in a compatible modules common platform that reduce maintenance and training costs with same spare parts in stock, and unique training for different Programmable Automation Controllers (PAC).

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Primary Voltage 24...48 V
Range Of Product Modicon X80
Product Or Component Type power supply module
Function Available
  • redundancy information
  • redundancy test
  • remaining lifetime
  • temperature sensing
  • uptime duration
Secondary Power
  • 18 W 3.3 V DC -25-60 °C I/O module logic power supply
  • 40 W 24 V DC -25-60 °C I/O module power supply and processor if 3.3 V not loaded
Supply Circuit Type DC
Product Compatibility all backplane
Mtbf Reliability 721000 H
Maximum Cable Distance Between Devices
  • 10 m
  • 15 m
Primary Voltage Limit 18...62.4 V
It On Activation
  • 0.3 A.s 24 V
  • 0.4 A.s 48 V
Status Led
  • 1 LED (Green) presence of voltages (OK)
  • 1 LED (Green) redundancy OK
  • 1 LED (Green) power supply status
I²T On Activation
  • 1 A².s 24 V
  • 3 A².s 48 V
Input Current
  • 1.9 A 24 V
  • 1 A 48 V
Current At Secondary Voltage
  • 1.67 A 24 V DC I/O module logic power supply
  • 5 A 3.3 V DC I/O module power supply and processor
Insulation Resistance
  • >= 100 MOhm primary/ground
  • >= 100 MOhm primary/secondary
Net Weight 0.81 kg
Control Type RESET push-button cold restart
Maximum Power Dissipation In W 8.5 W
Electrical Connection
  • 1 connector 2 alarm relay
  • 1 connector 5 line supply, protective earth
Inrush Current
  • 60 A 24 V
  • 60 A 48 V
Protection Type
  • internal fuse not accessible primary circuit
  • overload protection secondary circuit
  • overvoltage protection secondary circuit
  • short-circuit protection secondary circuit
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1710011EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI1710011EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Ambient Air Temperature For Operation -25-60 °C
Immunity To Microbreaks 1 ms
Standards
  • EN/IEC 61131-2
  • EN/IEC 61010-2-201
  • UL 61010-2-201
  • CSA C22.2 No 61010-2-201
  • IACS E10
  • EN/IEC 61000-6-5, interface type 1 and type 2
  • EN/IEC 61850-3, location G
  • EN/IEC 60079-0
Product Certifications
  • CE
  • UL
  • CSA
  • RCM
  • EAC
  • Merchant Navy
  • ATEX zone 2/22
  • IECEx zone 2/22
  • TÜV
Shock Resistance 15 gn
Environmental Characteristic
  • hazardous location class I division 2
  • gas resistant class Gx ISA S71.04
  • gas resistant class 3C4 IEC 60721-3-3
  • dust resistant class 3S4 IEC 60721-3-3
  • sand resistant class 3S4 IEC 60721-3-3
  • salt resistant level 2 IEC 68252
  • mold growth resistant class 3B2 IEC 60721-3-3
  • fungal spore resistant class 3B2 IEC 60721-3-3
Vibration Resistance 3 gn
Directives
  • 2014/30/EU - electromagnetic compatibility
  • 2006/42/EC - machinery
  • 2014/34/EU - ATEX directive
Ambient Air Temperature For Storage -40-85 °C
Relative Humidity 5-95 % 55-55 °C without condensation
Operating Altitude
  • 0...6561.68 ft (0...2000 m)
  • 2000...5000 m with derating factor
Protective Treatment conformal coating
Ip Degree Of Protection IP20
Dielectric Strength
  • 1500 V primary/ground
  • 1500 V primary/secondary
Documents