BGA260402 – Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, AC
BGA260402
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, AC

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 40A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Or Component Type circuit breaker
Product Name PowerPact B
Range PowerPact
Device Application distribution
Device Short Name BG 040
Mounting Mode I-Line
Network Frequency 50/60 Hz
[Ics] Rated Service Breaking Capacity
  • 65 kA 220...240 V AC 50/60 Hz IEC 60947-2
  • 18 kA 500...525 V AC 50/60 Hz IEC 60947-2
  • 35 kA 380...415 V AC 50/60 Hz IEC 60947-2
  • 35 kA 440 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology thermal-magnetic
Height 137 mm
Connection Pitch 27 mm
[Ue] Rated Operational Voltage 525 V AC 50/60 Hz UL 489
Tightening Torque
  • 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10)
  • 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Breaking Capacity Code G
9 Mm Pitches 6
Local Signalling presence of auxiliary contacts flag green)
Number Of Slots
  • 1 auxiliary switch OF plug-in)
  • 1 voltage release MN or MX plug-in)
Electrical Connection
  • I-Line connection line
  • lugs load
Mounting Height 76.2 mm
Net Weight 0.952 kg
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
Control Type toggle
Circuit Breaker Application HACR rated
Wire Stripping Length 20 mm
Utilisation Category category A
Line Rated Current 40-40 A
Continuous Current Rating 80 %
Breaking Capacity
  • 65 kA 208Y/120 V AC 50/60 Hz UL 489
  • 65 kA 240 V AC 50/60 Hz UL 489
  • 35 kA 480/277 V AC 50/60 Hz UL 489
  • 35 kA 480 V AC 50/60 Hz UL 489
  • 18 kA 250 V DC UL 489
  • 20 kA 600Y/347 V AC 50/60 Hz UL 489
[Ui] Rated Insulation Voltage 800 V IEC 60947-2
Mechanical Durability 20000 cycles IEC 947-1 Annex K ed 5.2
Suitability For Isolation yes IEC 60947-2
Electrical Durability 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Poles Description 2P
Quantity Per Set set of 1
Awg Gauge AWG 14...AWG 2/0 aluminium/copper
Color Gray RAL 7016)
Width 54 mm
Depth 89 mm
Phase Connection AC
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1610005EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive Compliant
Halogen Content Performance Halogen free product
Ik Degree Of Protection IK07 IEC 62262
Ambient Air Temperature For Operation -25-70 °C
Standards
  • EN/IEC 60947-5-1
  • EN/IEC 60947-2
  • NEMA AB1
  • CSA C22.2 No 5
  • UL 489
  • GB 14048.2
  • NMX J-266
Product Certifications
  • UL
  • IEC
  • CCC
  • EAC
  • CSA
  • NOM
Ip Degree Of Protection front cover IP40 IEC 60529
Pollution Degree 3 IEC 60947-1
Ambient Air Temperature For Storage -50-85 °C
Quality Labels CE
Operating Altitude
  • < 6561.68 ft (2000 m) without derating