This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for retrofit and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (including 50A, 100A or 200A split-core current transformers) on all branch channels. The BCPM allow the monitoring of both the branch circuits and mains values, incoming power and energy for a maximum of 42 circuits. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with serial connection for either Modbus RTU or BACnet MS/TP, and an Ethernet connection for Modbus TCP, BACnet IP and SNMP. The meter need to be powered by a 100V AC to 277V AC supply source. This version is for 42 circuits, but do not include branch current transformers nor ribbon. The device dimensions are 353mm in width, 253mm in height, 71mm in depth and weight 1.5 kilograms.
Brand: Schneider Electric
Add to Quote CatalogueNetwork Frequency |
|
---|---|
Energy Management | sub billing and cost allocation |
[Us] Rated Supply Voltage | 90...277 V AC 50/60 Hz +/- 1 % |
Power Quality Analysis | voltage sag and swell detection |
Variant | advanced + ethernet |
Type Of Measurement |
|
Power Monitoring | basic instrumentation |
Product Or Component Type | multi-circuit energy meter |
Product Name | PowerLogic BCPMSC |
Device Application | sub billing |
Device Short Name | BCPMSCE |
Range | PowerLogic |
Communication Port Support |
|
Measurement Accuracy |
|
Measurement Voltage |
|
Sampling Rate | 256 samples/cycle |
Communication Port Protocol |
|
Update Time | 1.8 s |
Analogue Input Type |
|
Communication Of Data |
|
Provided Equipment |
|
China Rohs Regulation | X |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Eu Rohs Directive | Compliant |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Ambient Air Temperature For Operation | 0-60 °C |
Height | 146 mm |
Mounting Mode | clip-on |
Ambient Air Temperature For Storage | -40-70 °C |
Relative Humidity | 95-95 % |
Standards |
|
Mounting Support | board |
Product Certifications | UL 508 |
Width | 288 mm |
Net Weight | 1.5 kg |
Operating Altitude | 9842.52 ft (3000 m) |