BCPMA248S – BCPM power monitoring advanced – 48 solid core 100 A – 18 mm CT spacing
BCPMA248S
BCPM power monitoring advanced - 48 solid core 100 A - 18 mm CT spacing

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors both the 48 branch circuits and mains values, incoming power and energy. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 4 18-CTs board strips with 18mm spacing between each CT connectors, for 48 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Network Frequency
  • 50 Hz
  • 60 Hz
Power Quality Analysis voltage sag and swell detection
Variant advanced
Type Of Measurement
  • voltage
  • current
  • frequency
  • active power
  • power factor
  • active energy
Power Monitoring basic instrumentation
Product Or Component Type multi-circuit energy meter
Product Name PowerLogic BCPM
Range PowerLogic
Energy Management sub billing and cost allocation
[Us] Rated Supply Voltage 90...277 V AC 50/60 Hz +/- 1 %
Device Application sub billing
Device Short Name BCPMA
Communication Port Support RS485
Connection Pitch 18 mm
Measurement Voltage
  • 90-277 V phase to neutral
  • 150-480 V phase to phase
Sampling Rate 256 samples/cycle
Communication Port Protocol Modbus RTU
Communication Of Data
  • low current alarm
  • over voltage alarm
  • high current alarm
  • under voltage alarm
  • high-high current alarm
  • low-low current alarm
Provided Equipment 48 x current transformer
Measurement Accuracy
  • branch current 2 % 0.25…2 A
  • branch current 1 % 2…100 A
  • mains current 3 % 1…100 %
  • mains current 3 % 2…100 %
  • voltage 1 % 90…277 V
Update Time 1.8 s
Analogue Input Type 48 solid core CT 100 A
Rohs Exemption Information Yes
Mercury Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Eu Rohs Directive Compliant
Height 146 mm
Standards
  • IEC 61036
  • EN 61010
  • UL 508
  • ANSI C12.1
Mounting Support
  • enclosure
  • panel
Product Certifications UL
Net Weight 1.5 kg
Mounting Mode panel-mounted
Ambient Air Temperature For Storage -40-70 °C
Relative Humidity 0-95 % 0-60 °C
Width 288 mm
Operating Altitude 9842.52 ft (3000 m)