This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 3kW/-HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 2.2kW/3HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 200Vac to 240Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
Brand: Schneider Electric
Add to Quote CatalogueProspective Line Isc | 50 kA |
---|---|
Network Frequency | 50-60 Hz |
Product Destination |
|
Line Current |
|
Phase | 3 phase |
Asynchronous Motor Control Profile |
|
Variant |
|
Product Or Component Type | variable speed drive |
Apparent Power |
|
Ip Degree Of Protection | IP21 |
Switching Frequency |
|
Maximum Transient Current |
|
Communication Port Protocol |
|
Product Specific Application | process for industrial |
Maximum Horse Power Rating | 3.0 hp heavy duty |
Option Card |
|
Degree Of Protection | UL type 1 |
Maximum Output Frequency | 599 Hz |
Range Of Product | Altivar Process ATV900 |
Motor Power Kw |
|
[Us] Rated Supply Voltage | 200...240 V - 15...10 % |
Mounting Mode | wall mount |
Discrete Input Logic | 16 preset speeds |
Continuous Output Current |
|
Nominal Switching Frequency | 4 kHz |
Emc Filter |
|
Device Application | Industrial Application |
Synchronous Motor Control Profile |
|
Discrete Input Logic |
|
Power Dissipation In W |
|
Analogue Output Type |
|
Discrete Output Type |
|
Maximum Switching Current |
|
4 Quadrant Operation Possible | true |
Exchange Mode | half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
Local Signalling |
|
Data Format | 8 bits, configurable odd, even or no parity Modbus serial |
Relative Symmetric Network Frequency Tolerance | 5 % |
Net Weight | 4.5 kg |
With Safety Function Safe Direction (Sdi) | false |
Type Of Polarization | no impedance |
Relay Output Type |
|
Analogue Input Number | 3 |
Motor Slip Compensation |
|
Discrete Output Number | 2 |
With Safety Function Safe Position (Sp) | false |
Transmission Rate |
|
Method Of Access | slave Modbus TCP |
With Safety Function Safely Limited Position (Slp) | false |
With Safety Function Safe Operating Stop (Sos) | false |
Number Of Addresses | 1-247 |
Discrete Input Number | 10 |
Linearity Error |
|
Number Of Addresses | 1-247 Modbus serial |
With Sft Fct Safe Stop 2 (Ss2) | false |
With Safety Function Safe Stop 1 (Ss1) | true |
Width | 144 mm |
Transmission Rate |
|
Depth | 206 mm |
Analogue Input Type |
|
Sampling Duration |
|
Electrical Connection |
|
With Safety Function Safe Brake Management (Sbc/Sbt) | true |
Height | 350 mm |
Acceleration And Deceleration Ramps | linear adjustable separately from 0.01...9999 s |
Maximum Output Voltage | 240.0 V |
Base Load Current At High Overload | 11.2 A |
Transmission Frame | RTU |
With Safety Function Safe Speed Monitor (Ssm) | false |
Relay Output Number | 3 |
With Safety Function Safe Torque Off (Sto) | true |
Data Format | 8 bits, configurable odd, even or no parity |
Base Load Current At Low Overload | 13.7 A |
Accuracy |
|
Input Compatibility |
|
Connector Type |
|
Analogue Output Number | 2 |
Physical Interface |
|
Minimum Switching Current | relay output R1, R2, R3 5 mA 24 V DC |
Refresh Time | relay output R1, R2, R3)5 ms +/- 0.5 ms) |
Isolation | between power and control terminals |
With Safety Function Safe Programmable Logic | false |
Brake Chopper Integrated | true |
Quantity Per Set | 1 |
Type Of Polarization | no impedance Modbus serial |
Braking To Standstill | by DC injection |
Discrete Input Type |
|
Protection Type |
|
Supply |
|
With Safety Function Safely Limited Speed (Sls) | true |
Mercury Free | Yes |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Upgradeability | Upgraded components available |
Rohs Exemption Information | Yes |
Environmental Disclosure | ENVPEP1501005EN |
Sustainable Offer Status | Green Premium product |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Circularity Profile | ENVEOLI1501005EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Product Certifications |
|
Maximum Deflection Under Vibratory Load (During Operation) | 1.5 mm at 2...13 Hz |
Standards |
|
Insulation Resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Shock Resistance | 15 gn 11 ms IEC 60068-2-27 |
Environmental Characteristic |
|
Vibration Resistance |
|
Noise Level | 54.5 dB 86/188/EEC |
Regulation Loop | adjustable PID regulator |
Permitted Relative Humidity (During Operation) | class 3K5 according to EN 60721-3 |
Operating Altitude |
|
Overvoltage Category | III |
Environmental Class (During Operation) |
|
Maximum Acceleration Under Shock Impact (During Operation) | 150 m/s² at 11 ms |
Pollution Degree | 2 |
Electromagnetic Compatibility |
|
Ambient Air Temperature For Operation |
|
Volume Of Cooling Air | 38 m3/h |
Marking | CE |
Maximum Acceleration Under Vibrational Stress (During Operation) | 10 m/s² at 13...200 Hz |
Noise Level | 54.5 dB |
Ambient Air Temperature For Storage | -40-70 °C |
Relative Humidity | 5-95 % without condensation IEC 60068-2-3 |
Assembly Style | enclosed |
Operating Position | vertical +/- 10 degree |
Maximum Thdi | <48 % full load IEC 61000-3-12 |
Ambient Air Transport Temperature | -40-70 °C |