Prospective Line Isc | 70 kA |
---|---|
Network Frequency | 50-60 Hz |
Product Destination |
|
Line Current |
|
Phase | 3 phase |
Asynchronous Motor Control Profile |
|
Variant |
|
Product Or Component Type | variable speed drive |
Apparent Power |
|
Ip Degree Of Protection | IP21 |
Switching Frequency |
|
Maximum Transient Current |
|
Communication Port Protocol |
|
Product Specific Application | process for industrial |
Maximum Horse Power Rating |
|
Option Card |
|
Degree Of Protection | UL type 1 |
Maximum Output Frequency | 599 Hz |
Range Of Product | Altivar Process ATV900 |
Motor Power Kw |
|
[Us] Rated Supply Voltage | 500...690 V - 15...10 % |
Mounting Mode | wall mount |
Discrete Input Logic | 16 preset speeds |
Continuous Output Current |
|
Nominal Switching Frequency | 4 kHz |
Emc Filter |
|
Device Application | Industrial Application |
Synchronous Motor Control Profile |
|
Discrete Input Logic |
|
Power Dissipation In W |
|
Analogue Output Type |
|
Discrete Output Type |
|
Maximum Switching Current |
|
4 Quadrant Operation Possible | true |
Exchange Mode | half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
Local Signalling |
|
Data Format | 8 bits, configurable odd, even or no parity Modbus serial |
Relative Symmetric Network Frequency Tolerance | 5 % |
Net Weight | 22 kg |
With Safety Function Safe Direction (Sdi) | false |
Type Of Polarization | no impedance |
Relay Output Type |
|
Analogue Input Number | 3 |
Motor Slip Compensation |
|
Discrete Output Number | 2 |
With Safety Function Safe Position (Sp) | false |
Transmission Rate |
|
Method Of Access | slave Modbus TCP |
With Safety Function Safely Limited Position (Slp) | false |
With Safety Function Safe Operating Stop (Sos) | false |
Number Of Addresses | 1-247 |
Discrete Input Number | 10 |
Linearity Error |
|
Number Of Addresses | 1-247 Modbus serial |
With Sft Fct Safe Stop 2 (Ss2) | false |
With Safety Function Safe Stop 1 (Ss1) | true |
Width | 246 mm |
Transmission Rate |
|
Depth | 242 mm |
Analogue Input Type |
|
Sampling Duration |
|
Electrical Connection |
|
With Safety Function Safe Brake Management (Sbc/Sbt) | true |
Height | 420 mm |
Acceleration And Deceleration Ramps |
|
Maximum Output Voltage | 690.0 V |
Base Load Current At High Overload | 29.0 A |
Transmission Frame | RTU |
With Safety Function Safe Speed Monitor (Ssm) | false |
Relay Output Number | 3 |
With Safety Function Safe Torque Off (Sto) | true |
Data Format | 8 bits, configurable odd, even or no parity |
Base Load Current At Low Overload | 34.0 A |
Accuracy |
|
Input Compatibility |
|
Connector Type |
|
Analogue Output Number | 2 |
Physical Interface |
|
Minimum Switching Current | relay output R1, R2, R3 5 mA 24 V DC |
Refresh Time | relay output R1, R2, R3)5 ms +/- 0.5 ms) |
Isolation | between power and control terminals |
With Safety Function Safe Programmable Logic | false |
Brake Chopper Integrated | true |
Quantity Per Set | 1 |
Type Of Polarization | no impedance Modbus serial |
Braking To Standstill | by DC injection |
Discrete Input Type |
|
Protection Type |
|
Supply |
|
With Safety Function Safely Limited Speed (Sls) | true |
Mercury Free | Yes |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Upgradeability | Upgraded components available |
Rohs Exemption Information | Yes |
Environmental Disclosure | ENVPEP1704001EN |
Sustainable Offer Status | Green Premium product |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Circularity Profile | ENVEOLI1704001EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Product Certifications |
|
Maximum Deflection Under Vibratory Load (During Operation) | 1.5 mm at 2...13 Hz |
Standards |
|
Insulation Resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Shock Resistance | 15 gn 11 ms IEC 60068-2-27 |
Environmental Characteristic |
|
Vibration Resistance |
|
Noise Level | 58 dB 86/188/EEC |
Regulation Loop | adjustable PID regulator |
Permitted Relative Humidity (During Operation) | class 3K5 according to EN 60721-3 |
Operating Altitude |
|
Overvoltage Category | III |
Environmental Class (During Operation) |
|
Maximum Acceleration Under Shock Impact (During Operation) | 150 m/s² at 11 ms |
Pollution Degree | 2 |
Electromagnetic Compatibility |
|
Ambient Air Temperature For Operation |
|
Volume Of Cooling Air | 330 m3/h |
Marking | CE |
Maximum Acceleration Under Vibrational Stress (During Operation) | 10 m/s² at 13...200 Hz |
Noise Level | 58 dB |
Ambient Air Temperature For Storage | -40-70 °C |
Relative Humidity | 5-95 % without condensation IEC 60068-2-3 |
Assembly Style | enclosed |
Operating Position | vertical +/- 10 degree |
Ambient Air Transport Temperature | -40-70 °C |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366