Variant | standard version |
---|---|
Product Or Component Type | variable speed drive |
Ip Degree Of Protection | IP20 |
Phase | 3 phase |
Communication Port Protocol |
|
Nominal Output Current | 16.5 A |
Product Specific Application | machine |
Maximum Horse Power Rating |
|
Supply Frequency | 50...60 Hz +/- 5 % |
Range Of Product | Altivar Machine ATV340 |
Motor Power Kw |
|
[Us] Rated Supply Voltage | 380...480 V - 15...10 % |
Mounting Mode | cabinet mount |
Emc Filter | class C3 EMC filter integrated |
Prospective Line Isc | 22 kA |
Power Dissipation In W |
|
Line Current |
|
Line Current |
|
Analogue Output Type |
|
Discrete Output Type | programmable output DQ1, DQ2 30 V DC 100 mA |
Electrical Connection |
|
Maximum Switching Current |
|
Asynchronous Motor Control Profile |
|
4 Quadrant Operation Possible | true |
Apparent Power |
|
Net Weight | 3.0 kg |
With Safety Function Safe Direction (Sdi) | false |
Type Of Polarization | no impedance |
Relay Output Type |
|
Switching Frequency |
|
Maximum Transient Current |
|
Analogue Input Number | 2 |
Motor Slip Compensation |
|
Discrete Output Number | 2.0 |
With Safety Function Safe Position (Sp) | false |
Method Of Access | slave Modbus RTU |
With Safety Function Safely Limited Position (Slp) | false |
With Safety Function Safe Operating Stop (Sos) | false |
Number Of Addresses | 1-247 |
Discrete Input Number | 5 |
With Sft Fct Safe Stop 2 (Ss2) | false |
With Safety Function Safe Stop 1 (Ss1) | true |
Width | 110.0 mm |
Transmission Rate |
|
Depth | 234.0 mm |
Analogue Input Type |
|
Electrical Connection |
|
Maximum Output Frequency | 0.599 kHz |
With Safety Function Safe Brake Management (Sbc/Sbt) | true |
Height | 270.0 mm |
Acceleration And Deceleration Ramps |
|
Maximum Output Voltage | 480 V |
Base Load Current At High Overload | 16.5 A |
Transmission Frame | RTU |
With Safety Function Safe Speed Monitor (Ssm) | false |
Relay Output Number | 2 |
With Safety Function Safe Torque Off (Sto) | true |
Data Format | 8 bits, configurable odd, even or no parity |
Base Load Current At Low Overload | 24.0 A |
Connector Type | 3 RJ45 |
Pollution Degree | 2 EN/IEC 61800-5-1 |
Analogue Output Number | 2 |
Physical Interface | 2-wire RS 485 |
Minimum Switching Current |
|
Discrete Input Logic | 16 preset speeds |
Continuous Output Current |
|
With Safety Function Safe Programmable Logic | false |
Brake Chopper Integrated | true |
Output Voltage | <= power supply voltage |
Nominal Switching Frequency | 4 kHz |
Braking To Standstill | by DC injection |
Discrete Input Type |
|
Protection Type |
|
With Safety Function Safely Limited Speed (Sls) | true |
Synchronous Motor Control Profile |
|
Mercury Free | Yes |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Rohs Exemption Information | Yes |
Environmental Disclosure | ENVPEP1609005EN |
Sustainable Offer Status | Green Premium product |
Pvc Free | Yes |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Circularity Profile | ENVEOLI1609005EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Product Certifications |
|
Maximum Deflection Under Vibratory Load (During Operation) | 1.5 mm at 2...9 Hz |
Standards |
|
Regulation Loop | adjustable PID regulator |
Permitted Relative Humidity (During Operation) | class 3K5 according to EN 60721-3 |
Operating Altitude | <= 9842.52 ft (3000 m) with current derating above 1000m |
Overvoltage Category | class III |
Environmental Class (During Operation) |
|
Maximum Acceleration Under Shock Impact (During Operation) | 70 m/s² at 22 ms |
Pollution Degree | 2 |
Electromagnetic Compatibility |
|
Ambient Air Temperature For Operation |
|
Volume Of Cooling Air | 76.0 m3/h |
Marking | CE |
Maximum Acceleration Under Vibrational Stress (During Operation) | 5 m/s² at 9...200 Hz |
Noise Level | 46.5 dB |
Ambient Air Temperature For Storage | -25-70 °C |
Type Of Cooling | forced convection |
Isolation | between power and control terminals |
Assembly Style | with heat sink |
Operating Position | vertical +/- 10 degree |
Ambient Air Transport Temperature | -40-70 °C |